Overview of condition monitoring and operation control of electric power conversion systems in direct-drive wind turbines under faults
Shoudao HUANG, Xuan WU, Xiao LIU, Jian GAO, Yunze HE
Overview of condition monitoring and operation control of electric power conversion systems in direct-drive wind turbines under faults
Electric power conversion system (EPCS), which consists of a generator and power converter, is one of the most important subsystems in a direct-drive wind turbine (DD-WT). However, this component accounts for the most failures (approximately 60% of the total number) in the entire DD-WT system according to statistical data. To improve the reliability of EPCSs and reduce the operation and maintenance cost of DD-WTs, numerous researchers have studied condition monitoring (CM) and fault diagnostics (FD). Numerous CM and FD techniques, which have respective advantages and disadvantages, have emerged. This paper provides an overview of the CM, FD, and operation control of EPCSs in DD-WTs under faults. After introducing the functional principle and structure of EPCS, this survey discusses the common failures in wind generators and power converters; briefly reviewed CM and FD methods and operation control of these generators and power converters under faults; and discussed the grid voltage faults related to EPCSs in DD-WTs. These theories and their related technical concepts are systematically discussed. Finally, predicted development trends are presented. The paper provides a valuable reference for developing service quality evaluation methods and fault operation control systems to achieve high-performance and high-intelligence DD-WTs.
direct-drive wind turbine / electric power conversion system / condition monitoring / fault diagnosis / operation control under faults / fault tolerance
[1] |
Qiao W, Lu D. A survey on wind turbine condition monitoring and fault diagnosis—Part I: Components and subsystems. IEEE Transactions on Industrial Electronics, 2015, 62(10): 6536–6545
CrossRef
Google scholar
|
[2] |
Qiao W, Lu D. A survey on wind turbine condition monitoring and fault diagnosis—Part II: Signals and signal processing methods. IEEE Transactions on Industrial Electronics, 2015, 62(10): 6546–6557
CrossRef
Google scholar
|
[3] |
Liu W, Tang B, Han J,
CrossRef
Google scholar
|
[4] |
Mirafzal B. Survey of fault-tolerance techniques for three-phase voltage source inverters. IEEE Transactions on Industrial Electronics, 2014, 61(10): 5192–5202
CrossRef
Google scholar
|
[5] |
Machado de Azevedo H D, Araújo A M, Bouchonneau N. A review of wind turbine bearing condition monitoring: State of the art and challenges. Renewable and Sustainable Energy Reviews, 2016, 56: 368–379
CrossRef
Google scholar
|
[6] |
Feng Y, Zhou J, Qiu Y,
CrossRef
Google scholar
|
[7] |
Qiu Y, Jiang H, Feng Y,
CrossRef
Google scholar
|
[8] |
Tian Z, Jin T, Wu B,
|
[9] |
Yang D, Li H, Hu Y,
CrossRef
Google scholar
|
[10] |
Cheng M, Zhu Y, The state of the art of wind energy conversion systems and technologies: A review. Energy Conversion and Management, 2014, 88: 332–347
CrossRef
Google scholar
|
[11] |
Nasiri M, Milimonfared J, Fathi S H. A review of low-voltage ride-through enhancement methods for permanent magnet synchronous generator based wind turbines. Renewable and Sustainable Energy Reviews, 2015, 47: 399–415
CrossRef
Google scholar
|
[12] |
Thomson W T. On-line MCSA to diagnose shorted turns in low voltage stator windings of 3-phase induction motors prior to failure. In: Proceedings of the IEEE International Electric Machines and Drives Conference. IEEE, 2001, 891–898
CrossRef
Google scholar
|
[13] |
Tallam R M, Habetler T G, Harley R G. Stator winding turn-fault detection for closed-loop induction motor drives. IEEE Transactions on Industry Applications, 2003, 39(3): 720–724
CrossRef
Google scholar
|
[14] |
Nandi S, Toliyat H. Novel frequency-domain-based technique to detect stator interturn faults in induction machines using stator-induced voltages after switch-off. IEEE Transactions on Industry Applications, 2002, 38(1): 101–109
CrossRef
Google scholar
|
[15] |
Kliman G B, Premerlani W J, Koegl R A,
CrossRef
Google scholar
|
[16] |
Li H, Sun L, Xu B.
CrossRef
Google scholar
|
[17] |
Joksimovic G M, Penman J. The detection of inter-turn short circuits in the stator windings of operating motors. IEEE Transactions on Industrial Electronics, 2000, 47(5): 1078–1084
CrossRef
Google scholar
|
[18] |
Cruz S M Z, Cardoso A J M. Stator winding fault diagnosis in three-phase synchronous and asynchronous motors, by the extended Park’s vector approach. IEEE Transactions on Industry Applications, 2001, 37(5): 395–401
CrossRef
Google scholar
|
[19] |
Penman J, Sedding H G, Lloyd B A,
CrossRef
Google scholar
|
[20] |
Melero M G, Cabanas M F. Study of an induction motor working under stator winding inter-turn short circuit condition. In: Proceedings of 4th IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives. Atlanta: IEEE, 2003, 423–429
CrossRef
Google scholar
|
[21] |
Henao H, Demian C, Capolino G A. A frequency-domain detection of stator winding faults in induction machines using an external flux sensor. IEEE Transactions on Industry Applications, 2003, 39(5): 1272–1279
CrossRef
Google scholar
|
[22] |
Guo C, Zhang L, Wang Z. Fault diagnosis of AC motor on the vibrating spectral analysis. Oil Field Machinery, 2005, 34(4): 21–23 (in Chinese)
|
[23] |
Cao C. Real-time detecting signal of motor vibration based on wavelet packet decomposition. Electric Machines and Control Applications, 2005, 32(8): 58–61 (in Chinese)
|
[24] |
Amaral T G, Pires V F, Martins J F,
CrossRef
Google scholar
|
[25] |
Lee S B, Habetler T G, Harley R G,
CrossRef
Google scholar
|
[26] |
Lee S B, Habetler T G.An online stator winding resistance estimation technique for temperature monitoring of line-connected induction machines. IEEE Transactions on Industry Application, 2003, 4, 39(3): 685–694
CrossRef
Google scholar
|
[27] |
Gao Z, Habetler T G, Harley R G,
CrossRef
Google scholar
|
[28] |
Briz F, Degner M W, Guerrero J M,
CrossRef
Google scholar
|
[29] |
Beguenane R,Benbouzid M E H.Induction motors thermal monitoring by means of rotor resistance identification. IEEE Transactions on Energy Conversion, 1999, 14(3): 566–570
CrossRef
Google scholar
|
[30] |
Grubic S, Aller J M, Lu B,
CrossRef
Google scholar
|
[31] |
Stone G C. Advancements during the past quarter century in on-line monitoring of motor and generator winding insulation. IEEE Transactions on Dielectrics and Electrical Insulation, 2002, 9(5): 746–751
CrossRef
Google scholar
|
[32] |
Stone G C, Boulter E A, Culbert I,
|
[33] |
Tozzi M, Cavallini A, Montanari G C. Monitoring off-line and on-line PD under impulsive voltage on induction motors—Part 1: Standard procedure. IEEE Electrical Insulation Magazine, 2010, 26(4): 16–26
CrossRef
Google scholar
|
[34] |
Wang C, Wang Z, Li F,
CrossRef
Google scholar
|
[35] |
Li G, Yi K. Study on using thermal infrared imaging technology detecting the iron core faults of generator. Ningxia Electric Power, 2012, 12(6): 5–7
|
[36] |
Posedel Z. Inspection of stator cores in large machines with a low yoke induction method-measurement and analysis of interlamination short-circuits. IEEE Transactions on Energy Conversion, 2001, 16(1): 81–86
CrossRef
Google scholar
|
[37] |
Sarikhani A, Mirafzal B, Mohammed O. Inter-turn fault diagnosis of PM synchronous generator for variable speed wind applications using floating-space-vector. In: Proceedings of IECON 2010— 36th Annual Conference on IEEE Industrial Electronics Society. IEEE, 2010, 2628–2633
CrossRef
Google scholar
|
[38] |
Ding F, Trutt F C. Calculation of frequency spectra of electromagnetic vibration for wound-rotor induction machines with winding faults. Electric Machines and Power Systems, 1988, 14(3–4): 137–150
CrossRef
Google scholar
|
[39] |
Hameed Z, Hong Y S, Cho Y M,
CrossRef
Google scholar
|
[40] |
Zhang R, Wang X, Yang Y,
|
[41] |
Qiu Z, LiC, Zhou X,
|
[42] |
Tang R. Modern Permanent Magnet Machines Theory and Design. Beijing: China Machine Press, 2008, 18–21 (in Chinese)
|
[43] |
Hao H, Chai J, Jiang Z,
|
[44] |
Xiao X, Zhang M, Li Y. On-line estimation of permanent-magnet flux linkage ripple for PMSM. Proceedings of the CSEE, 2007, 27(24): 142–146 (in Chinese)
|
[45] |
Qi F. Magnetic stability of permanent magnet materials. Journal of magnetic Materials and Devices, 1998, 29(5): 26–31 (in Chinese)
|
[46] |
von Staa F,Hempel K A, ArtzH. On the energy losses of hot worked Nd-Fe-B magnets and ferrites in a small alternating magnetic field perpendicular to a bias field. IEEE Transactions on Magnetics, 1995, 31(6): 3650–3652
CrossRef
Google scholar
|
[47] |
Xiao X, Zhang M, Li Y. Permanent magnet synchronous motor permanent magnet condition on-line monitoring. Proceedings of the CSEE, 2007, 27(24): 43–47 (in Chinese)
|
[48] |
Shinnaka S. New “D-State-Observer”-based vector control for sensorless drive of permanent-magnet synchronous motors. IEEE Transactions on Industry Applications, 2005, 41(3): 825–833
CrossRef
Google scholar
|
[49] |
Chen Z, Tomita M, Doki S,
CrossRef
Google scholar
|
[50] |
Eskola M, Tuusa H. Comparison of MRAS and novel simple method for position estimation in PMSM drives. In: Proceedings of IEEE 34th Annual Power Electronics Specialist Conference. Acapulco: IEEE, 2003
CrossRef
Google scholar
|
[51] |
Krishnan R, Vijayraghavan P. Fast estimation and compensation of rotor flux linkage in permanent magnet synchronous machines. In: Proceedings of the IEEE International Symposium on Industrial Electronics. IEEE, 1999
CrossRef
Google scholar
|
[52] |
Tchakoua P, Wamkeue R, Ouhrouche M,
CrossRef
Google scholar
|
[53] |
García Márquez F P, Tobias A M, Pinar Pérez J M,
CrossRef
Google scholar
|
[54] |
Yang W, Tavner P J, Tian W. Wind turbine condition monitoring based on an improved spline-kernelled chirplet transform. IEEE Transactions on Industrial Electronics, 2015, 62(10): 6565–6574
CrossRef
Google scholar
|
[55] |
Astolfi D, Castellani F, Terzi L. Fault prevention and diagnosis through SCADA temperature data analysis of an onshore wind farm. Diagnostyka, 2014, 15(2): 71–78
|
[56] |
Shahriar M R, Wang L, Kan M S,
|
[57] |
Guo P, Infield D. Wind turbine tower vibration modeling and monitoring by the nonlinear state estimation technique (NSET). Energies, 2012, 5(12): 5279–5293
CrossRef
Google scholar
|
[58] |
Yang H, Mathew J, Ma L. Vibration feature extraction techniques for fault diagnosis of rotating machinery: A literature survey. In: Proceedings of Asia-Pacific Vibration Conference. Gold Coast, 2003
|
[59] |
Hameed Z, Ahn S, Cho Y. Practical aspects of a condition monitoring system for a wind turbine with emphasis on its design, system architecture, testing and installation. Renewable Energy, 2010, 35(5): 879–894
CrossRef
Google scholar
|
[60] |
Costinas S, Diaconescu I, Fagarasanu J. Wind power plant condition monitoring. In: Proceedings of the 3rd WSEAS International Conference on Energy Planning, Energy Saving, Environmental Education. Tenerife, 2009, 71–76
|
[61] |
Rogers A L, Manwell J F, Wright S. Wind Turbine Acoustic Noise. White paper. 2002/2006
|
[62] |
Salon S, Salem S, Sivasubramaniam K. Monitoring and diagnostic solutions for wind generators. In: Proceedings of IEEE Power and Energy Society General Meeting. IEEE, 2011
CrossRef
Google scholar
|
[63] |
Niknam S A, Thomas T, Hines J W,
|
[64] |
Ma Y, He C, Feng X. Institutions function and failure statistic and analysis of wind turbine. Physics Procedia, 2012, 24(Part A): 25–30
CrossRef
Google scholar
|
[65] |
Yang W, Court R, Jiang J. Wind turbine condition monitoring by the approach of SCADA data. Renewable Energy. 2013, 53(9): 365–376
CrossRef
Google scholar
|
[66] |
Patil N, Das D, Goebel K,
CrossRef
Google scholar
|
[67] |
Yang L, Agyakwa P A, Johnson C M. A time-domain physics-of-failure model for the lifetime prediction of wire bond interconnects. Microelectronics and Reliability, 2011, 51(9–11): 1882–1886
CrossRef
Google scholar
|
[68] |
Li H, Liu S, Ran L,
|
[69] |
Jabłoński A, Barszcz T, Bielecka M. Automatic validation of vibration signals in wind farm distributed monitoring systems. Measurement, 2011, 44(10): 1954–1967
CrossRef
Google scholar
|
[70] |
Liang Y, Fang R. An online wind turbine condition assessment method based on SCADA and support vector regression. Automation of Electric Power Systems, 2013, 37(14): 7–12 (in Chinese)
|
[71] |
Guo P, Xu M, Bai N,
|
[72] |
Dai J, Yuan X, Liu D,
|
[73] |
Isermann R. Model-based fault detection and diagnosis-status and applications. Annual Reviews in Control, 2004, 29(1): 71–85
CrossRef
Google scholar
|
[74] |
Mahyob P, Reghem P, Barakat G. Permeance network modeling of the stator winding faults in electrical machines. IEEE Transactions on Magnetics, 2009, 45(3): 1820–1823
CrossRef
Google scholar
|
[75] |
Kim B W, Kim K T, Hur J. Simplified impedance modeling and analysis for inter-turn fault of IPM-type BLDC motor. Journal of Power Electronics, 2012, 12(1): 10–18
|
[76] |
Yazidi A, Henao H, Capolino G. Double-fed three-phase induction machine model for simulation of inter-turn short circuit fault. In: Proceedings of IEEE International Electric Machines and Drives Conference. IEEE, 2009, 571–576
CrossRef
Google scholar
|
[77] |
Zhu D, Tan K. Present situation and prospects of condition monitoring and fault diagnosis technology for electrical equipments. Electrical Equipment, 2003, 4(6): 1–8 (in Chinese)
|
[78] |
Widodo A, Yang B S, Gu D S,
CrossRef
Google scholar
|
[79] |
Cusido J, Romeral L, Ortega J A,
CrossRef
Google scholar
|
[80] |
Jung J H, Lee J J, Kwon B H. Online diagnosis of induction motors using MCSA. IEEE Transactions on Industrial Electronics, 2006, 53(6): 1842–1852
CrossRef
Google scholar
|
[81] |
Cusido J, Rosero J A, Ortega J A,
CrossRef
Google scholar
|
[82] |
Chetwani S H, Shah M K, Ramamoorty M. Online condition monitoring of induction motors through signal processing. In: Proceedings of 8th International Conference on Electrical Machines and Systems. IEEE, 2005, 2175–2179
CrossRef
Google scholar
|
[83] |
Wu G. Theory and Practice of the State Monitoring of Motor Equipment. Beijing: Tsinghua University Press, 2005 (in Chinese)
|
[84] |
Liu M, Cui S, GuoB. A method of failure recognition based on fuzzy C-means support vector machines for permanent magnetic DC motor. Micromotors, 2011, 44(10): 78–80 (in Chinese)
CrossRef
Google scholar
|
[85] |
Xu Y, Xu J, Guo X. Fuzzy diagnostic system for induction motor based on wavelet analysis and RBF neural network. Research and Exploration in Laboratory, 2012, 28(4): 282–301
|
[86] |
Chen X. Fault diagnosis of electro-mechanical equipment based on noise signal processing. Machine Tool and Hydraulic, 2005, 65(12): 183–186 (in Chinese)
|
[87] |
Tan Y, He Y, Cui C. A novel method for analog fault diagnosis based on neural networks and genetic algorithm. IEEE Transactions on Instrumentation and Measurement, 2008, 57(11): 2631–2639
CrossRef
Google scholar
|
[88] |
Su H, Chong K T. Induction machine condition monitoring using neural network modeling. IEEE Transactions on Industrial Electronics, 2007, 54(1): 241–249
CrossRef
Google scholar
|
[89] |
Valtierra-Rodriguez M, de Jesus Romero-Troncoso R, Osornio-Rios R A,
CrossRef
Google scholar
|
[90] |
Wang X, Kruger U, Irwin G W,
CrossRef
Google scholar
|
[91] |
Huang X, Wang J. The network generation technique of crack tracking. Journal of Shanghai Jiaotong University, 2001, 35(4): 493–495 (in Chinese)
|
[92] |
Wang C, Zheng C. Semi-analytical finite element method for plane crack stress intensity factor. Engineering Mechanics, 2005, 22(1): 33–37 (in Chinese)
|
[93] |
Yang T, Ren Y, Liu X,
|
[94] |
Jiang D. Huang Q, Hong L. Theoretical and experimental study on wind wheel unbalance for a wind turbine. In: Proceedings of World Non-Grid-Connected Wind Power and Energy Conference. IEEE, 2009
CrossRef
Google scholar
|
[95] |
Yuji T, Bouno T, Hamada T. Suggestion of temporarily for forecast diagnosis on blade of small wind turbine. IEEJ Transactions on Power and Energy, 2006, 126(7): 710–711
CrossRef
Google scholar
|
[96] |
Bouno T, Yuji T, Hamada T,
|
[97] |
Qian Y, Ma H. A survey of fault diagnosis method for doubly-fed induction motor. Large electric Machine and Hydraulic Turbine, 2011, (5): 5–8 (in Chinese)
|
[98] |
Le Roux W, Harley R G, Habetler T G. Detecting rotor faults in permanent magnet synchronous machines. In: Proceedings of 4th IEEE International Symposium on Diagnostics for Electric Machines, Power Electronic Sand Drives. IEEE, 2003, 198–203
CrossRef
Google scholar
|
[99] |
Le Roux W, Harley R G, Habetler T G. Converter control effects on condition monitoring of rotor faults in permanent magnet synchronous machines. In: Proceedings of the Industry Applications Conference. 38th IAS Annual Meeting. IEEE, 2003, 1389–1396
CrossRef
Google scholar
|
[100] |
Rosero J, Romeral L, Ortega J A,
CrossRef
Google scholar
|
[101] |
Ruiz J R R, Rosero J A, Espinosa A G,
CrossRef
Google scholar
|
[102] |
Rosero J A, Cusido J, Garcia A,
CrossRef
Google scholar
|
[103] |
Farooq J, Srairi S, Djerdir A,
CrossRef
Google scholar
|
[104] |
Wymore M L, Dam J E V, Ceylan H,
CrossRef
Google scholar
|
[105] |
Jöckel S, Herrmann A, Rink J. High energy production plus built-in reliability—The VENSYS 70/77—New gearless wind turbines in the 1.5 MW class. Presentation in the Technical Track of the European Wind Energy Conference. 2006
|
[106] |
Dubois M R, Polinder H, Ferreira J A. Generator topologies for direct-drive wind turbines, and adapted technology for turbines running in cold climate. In: Proceedings of Conference on Wind Energy in Cold Climates. Matane, 2001, 201–215
|
[107] |
Dubois M R, Polinder H, Ferreira J A. Comparison of generator topologies for direct-drive wind turbines. In: Proceedings of Nordic Countries Power and Industrial Electronics Conference (NORPIE). Aalborg, 2000
|
[108] |
Versteegh C J A. Design of the Zephyros Z72 wind turbine with emphasis on the direct drive PM generator. In: Proceedings of Nordic Countries Power and Industrial Electronics Conference (NORPIE). Trondheim, 2004
|
[109] |
An X, Jiang D. Chaotic characteristics identification and trend prediction of running state for wind turbine. Electric Power Automation Equipment, 2010, 30(3): 15–19, 24 (in Chinese)
|
[110] |
An X, Jiang D, Liu S,
|
[111] |
ZhangY, WuW, Wu L.Motor mechanical fault diagnosis based on wavelet packet, Shannon entropy, SVM and GA. Electric Power Automation Equipment, 2010, 30(1): 87–91 (in Chinese)
|
[112] |
Gu Y, Zhao W, Wu Z. Combustion optimization for utility boiler based on least square-support vector machine. Proceedings of the CSEE, 2010, 30(17): 91–97 (in Chinese)
|
[113] |
Zhao M. Fault Feature Analysis and Experimental Investigation for Wind Turbine. Beijing: Tsinghua University Press, 2010 (in Chinese)
|
[114] |
Barszcz T. Application of diagnostic algorithms for wind turbines. Diagnostyka, 2009, 50(2): 7–12
|
[115] |
Wu Z, Huang N, Long S,
CrossRef
Google scholar
|
[116] |
Pierre Tchakoua, René Wamkeue, Tommy Andy Tameghe,
CrossRef
Google scholar
|
[117] |
Izelu C O, Oghenevwaire I S. A review on developments in the design and analysis wind turbine drive train. In: Proceedings of International Conference on Renewable Energy Research and Applications. IEEE, 2014, 589–594
CrossRef
Google scholar
|
[118] |
Estima J O, Cardoso A J M. Fast fault detection, isolation and reconfiguration in fault-tolerant permanent magnet synchronous motor drives. In: Proceedings of IEEE Energy Convers. 2012, 3617–3624
|
[119] |
Lu B, Sharma S K. A literature review of IGBT fault diagnostic and protection methods for power inverters. IEEE Transactions on Industry Applications, 2009, 45(5): 1770–1777
CrossRef
Google scholar
|
[120] |
de Araujo Ribeiro R L, Jacobina C B, da Silva E R C,
CrossRef
Google scholar
|
[121] |
Khomfoi S, Tolbert L M. Fault diagnostic system for a multilevel inverter using a neural network. IEEE Transactions on Power Electronics, 2007, 22(3): 1062–1069
CrossRef
Google scholar
|
[122] |
Tavnet P J, Van Bussel G J W, Spinato F. Machine and converter reliabilities in wind turbines. In: Proceedings of 3rd IET International Conference on Power electronics, Machines and Drives. Dublin: IET, 2006, 127–130
|
[123] |
Jlassi I, Estima J O, Khojet El Khil S,
CrossRef
Google scholar
|
[124] |
Choi U M, Jeong H G, Lee K B,
CrossRef
Google scholar
|
[125] |
Freire N M A, Estima J O, Marques Cardoso A J. Open-circuit fault diagnosis in PMSG drives for wind turbine applications. IEEE Transactions on Industrial Electronics, 2013, 60(9): 3957–3967
CrossRef
Google scholar
|
[126] |
Fang Z P. Z-source inverter. IEEE Transactions on Industry Applications, 2003, 39(2): 504–510
CrossRef
Google scholar
|
[127] |
Faulstich S, Hahn B, Tavner P J. Wind turbine downtime and its importance for offshore deployment. Wind Energy (Chichester, England), 2011, 14(3): 327–337
CrossRef
Google scholar
|
[128] |
Gao Z, Cecati C, Ding S X. A survey of fault diagnosis and fault-tolerant techniques—Part I: Fault diagnosis with model-based and signal-based approaches. IEEE Transactions on Industrial Electronics, 2015, 62(6): 3757–3767
CrossRef
Google scholar
|
[129] |
Gao Z, Cecati C, Ding S X. A survey of fault diagnosis and fault-tolerant techniques—Part II: Fault diagnosis with knowledge-based and hybrid/active approaches. IEEE Transactions on Industrial Electronics, 2015, 62(6): 3768–3774
CrossRef
Google scholar
|
[130] |
Schulte H, Gauterin E. Fault-tolerant control of wind turbines with hydrostatic trans-mission using Takagi-Sugeno and sliding mode techniques. Annual Reviews in Control, 2015, 40(17): 82–92
CrossRef
Google scholar
|
[131] |
Corradini M L, Ippoliti G, Orlando G. Sensorless efficient fault-tolerant control of wind turbines with geared generator. Automatica, 2015, 62(11): 161–167
CrossRef
Google scholar
|
[132] |
Guan H, Zhao H, Wang W,
|
[133] |
Hu S, Li J, XuH. Modeling on converters of direct-driven wind power system and its performance during voltage sags. High Voltage Engineering, 2008, 34(5): 949–954 (in Chinese)
|
[134] |
Freitas W, Morelato A, Xu W. Improvement of induction generator stability using braking resistors. IEEE Transactions on Power Systems, 2004, 19(2): 1247–1249
CrossRef
Google scholar
|
[135] |
Causebrook A, Atkinson D J, Jack A G. Fault ride-through of large wind farms using series dynamic braking resistors. IEEE Transactions on Power Systems, 2007, 22(3): 966–975
CrossRef
Google scholar
|
[136] |
Fatu M, Lascu C, Andreescu G D,
CrossRef
Google scholar
|
[137] |
Li J, Hu S, Kong D,
|
[138] |
Li H, Dong S, Wang Y,
|
[139] |
Schulte H, Gauterin E. Fault-tolerant control of wind turbines with hydrostatic transmission using Takagi-Sugeno and sliding mode techniques. Annual Reviews in Control, 2015, 40: 82–92
CrossRef
Google scholar
|
[140] |
Zhang Z, Xu J, Liu X. Research on the high performance flux-weakening control strategy of permanent magnetic synchronous generator for wind turbine. High Power Converter Technology, 2013, 27(3): 62–65 (in Chinese)
|
[141] |
Chai F, Bi Y. Research review of flux-weakening methods of axial flux permanent magnet synchronous machine. Micromotors, 2015, (2): 70–76 (in Chinese)
|
[142] |
Li Z, Li Y, Li X. Flux-weakening control of consequent-pole permanent magnet machines. Proceedings of the CSEE, 2013, (21): 124–131 (in Chinese)
|
[143] |
Parsa L, Toliyat H. Multi-phase permanent-magnet motor drives. IEEE Transactions on Industry Applications, 2005, 41(1): 30–37
CrossRef
Google scholar
|
[144] |
Fu J R, Lipo T A. Disturbance-free operation of a multiphase current-regulated motor drive with an opened phase. IEEE Transactions on Industry Applications, 1994, 30(5): 1267–1274
CrossRef
Google scholar
|
[145] |
Toliyat H A. Analysis and simulation of five-phase variable speed induction motor drives under asymmetrical connections. IEEE Transactions on Power Electronics, 1998, 13(4): 748–756
CrossRef
Google scholar
|
[146] |
Dwari S, Parsa L. Fault-tolerant control of five-phase permanent-magnet motors with trapezoidal back EMF. IEEE Transactions on Industrial Electronics, 2011, 58(2): 476–485
CrossRef
Google scholar
|
[147] |
Liu T H, Fu J R, Lipo T A. A strategy for improving reliability of field oriented controlled induction motor drives. IEEE Transactions on Industry Applications, 1993, 29(5): 910–918
CrossRef
Google scholar
|
[148] |
Sinha G, Hochgraf C, Lasseter R H,
CrossRef
Google scholar
|
[149] |
Bianchi N, Bolognani S, Zigliotto M,
CrossRef
Google scholar
|
[150] |
Athulya Justin, Reshma S. Fault tolerant control of wind energy conversion system—Fuzzy approach. In: Proceedings of the Fourth International Conference on Computing, Communications and Networking Technologies (ICCCNT). Acapulco: IEEE, 2013
CrossRef
Google scholar
|
[151] |
de Araujo Ribeiro R L, Jacobina C B, da Silva E R C,
CrossRef
Google scholar
|
[152] |
Welchko B A, Lipo T A, Jahns T M,
CrossRef
Google scholar
|
[153] |
Tiegna H, Amara Y, Barakat G,
CrossRef
Google scholar
|
[154] |
Chowdhury M M, Haque M E, Aktarujjaman M,
CrossRef
Google scholar
|
[155] |
Polinder H, Ferreira J A, Jensen B B,
CrossRef
Google scholar
|
[156] |
Huang S, Gao J. The Design and Grid-Connected Control of Direct-Drive Permanent Magnet Wind Turbine. Beijing: Publishing House of Electronics Industry, 2015, 15–19 (in Chinese)
|
[157] |
Alepuz S, Calle A, Busquets-Monge S,
|
[158] |
Scarcella G, Scelba G, Pulvirenti M,
CrossRef
Google scholar
|
[159] |
YangZ, Chai Y. A survey of fault diagnosis for onshore grid-connected converter in wind energy conversion systems. Renewable and Sustainable Energy Reviews, 2016, 66: 345–359
CrossRef
Google scholar
|
[160] |
Huang S, Wang H, Liao W,
|
[161] |
Huang S, Wang H, Liao W,
|
[162] |
Arani M F M, Mohamed Y A R I. Assessment and enhancement of a full-scale PMSG-based wind power generator performance under faults. IEEE Transactions on Energy Conversion, 2016, 31(2): 728–739
CrossRef
Google scholar
|
[163] |
Zmood D N, Holmes D G. Stationary frame current regulation of PWM inverters with zero steady-state error. IEEE Transactions on Power Electronics, 2003, 18(3): 814–822
CrossRef
Google scholar
|
[164] |
Nian H, Cheng P. Resonant based direct power control strategy for PWM rectifier under unbalanced grid voltage condition. Transactions of China Electrotechnical Society, 2013, 28(11): 86–94 (in Chinese)
|
[165] |
Huang S, Xiao L, Huang K,
|
[166] |
Huang S, Xiao L, Huang K,
|
[167] |
Xiao L, Huang S, Lu K. DC-bus voltage control of grid-connected voltage source converter by using space vector modulated direct power control under unbalanced network conditions. IET Power Electronics, 2013, 6(5): 925–934
CrossRef
Google scholar
|
[168] |
Hasegawa N, Kumano T. Low voltage ride-through capability improvement of wind power generation using dynamic voltage restorer. In: Proceedings of the 5th IASME/WSEAS International Conference on Energy and Environment. 2010, 166–171
|
[169] |
Wang L, Truong D N. Dynamic stability improvement of four parallel-operated PMSG-based off shore wind turbine generators fed to a power system using a STATCOM. IEEE Transactions on Power Delivery, 2013, 28(1): 111–119
CrossRef
Google scholar
|
/
〈 | 〉 |