Hierarchical parameter estimation of DFIG and drive train system in a wind turbine generator

Xueping PAN , Ping JU , Feng WU , Yuqing JIN

Front. Mech. Eng. ›› 2017, Vol. 12 ›› Issue (3) : 367 -376.

PDF (318KB)
Front. Mech. Eng. ›› 2017, Vol. 12 ›› Issue (3) : 367 -376. DOI: 10.1007/s11465-017-0429-y
RESEARCH ARTICLE
RESEARCH ARTICLE

Hierarchical parameter estimation of DFIG and drive train system in a wind turbine generator

Author information +
History +
PDF (318KB)

Abstract

A new hierarchical parameter estimation method for doubly fed induction generator (DFIG) and drive train system in a wind turbine generator (WTG) is proposed in this paper. Firstly, the parameters of the DFIG and the drive train are estimated locally under different types of disturbances. Secondly, a coordination estimation method is further applied to identify the parameters of the DFIG and the drive train simultaneously with the purpose of attaining the global optimal estimation results. The main benefit of the proposed scheme is the improved estimation accuracy. Estimation results confirm the applicability of the proposed estimation technique.

Keywords

wind turbine generator / DFIG / drive train system / hierarchical parameter estimation method / trajectory sensitivity technique

Cite this article

Download citation ▾
Xueping PAN, Ping JU, Feng WU, Yuqing JIN. Hierarchical parameter estimation of DFIG and drive train system in a wind turbine generator. Front. Mech. Eng., 2017, 12(3): 367-376 DOI:10.1007/s11465-017-0429-y

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

Rose JHiskens  I A. Estimating wind turbine parameters and qualifying their effects on dynamic behavior. In: Proceedings of 2008 IEEE Power and Energy Society General Meeting Conversion and Delivery of Electrical Energy in the 21st Century. Pennsylvania2008, 1–7

[2]

Pan XJu  PXu Q . A two-step method for estimating DFIG parameters in a wind turbine and the measurement selection. Proceedings of the CSEE201333(13): 116–126 (in Chinese)

[3]

IEEE Guide: Test Procedures for Synchronous Machines. IEEE Standard 115-20092010

[4]

IEEE Guide: Identification, Testing, and Evaluation of the Dynamic Performance of Excitation Control Systems. IEEE Standard 421.2-19901990

[5]

Asmine MBrochu  JFortmann J . Model validation for wind turbine generator models. IEEE Transactions on Power Systems201126(3): 1769–1782

[6]

Marvik J IEndegnanew  A G. Wind turbine model validation with measure. Energy Procedia201224: 143–150

[7]

Jiménez FVigueras-Rodriguez  AGómez-Lázaro  E. Validation of a mechanical model for fault ride-through: Application to a Gamesa G52 commercial wind turbine. IEEE Transactions on Energy Conversion201328(3): 707–715 doi:10.1109/TEC.2013.2267493

[8]

Jiménez FGómez-Lázaro  EFuentes J A . Validation of a double fed induction generator wind turbine model and wind farm verification following the Spanish grid code. Wind Energy (Chichester, England)201215(4): 645–659 doi:10.1002/we.498

[9]

Jiménez FGómez-Lázaro  EFuentes J A . Validation of a DFIG wind turbine model submitted to two-phase voltage dips following the Spanish grid code. Renewable Energy201357: 27–34 doi:10.1016/j.renene.2012.12.032

[10]

Trilla LGomis-Bellmunt  OJunyent-Ferré A. Modeling and validation of DFIG 3-MW wind turbine using field test data of balanced and unbalanced voltage sags. IEEE Transactions on Power Systems20112(4): 509–519

[11]

Brochu JLarose  CGagnon R . Validation of single- and multiple-machine equivalents for modeling wind power plants. IEEE Transactions on Energy Conversion201026(2): 532–541

[12]

Pedersen J KHelgelsen-Pedersen  K OKjølstad Poulsen  N. Contribution to a dynamic wind turbine model validation from a wind farm islanding experiment. Electric Power Systems Research200364(1): 41–51 doi:10.1016/S0378-7796(02)00144-X

[13]

van der Veen G J van Wingerden J W Fleming P A . Global data-driven modelling of wind turbines in the presence of turbulence. Control Engineering Practice201321(4): 441–454 doi:10.1016/j.conengprac.2012.12.008

[14]

Kennedy J MFox  BLittler T . Validation of fixed speed induction generator models for inertial response using wind farm measurements. IEEE Transactions on Power Systems201126(3): 1454–1461

[15]

González-Longatt F Regulski P Wall P. Fixed speed wind generator model parameter estimation using improved particle swarm optimization and system frequency disturbances. In: Proceedings of IET Conference on Renewable Power Generation. Edinburgh: IEEE, 2011, 1–6

[16]

Bekker J CVermeulen  H J. Parameter estimation of a doubly-fed induction generator in a wind generation topology. In: Proceedings of 47th International Universities Power Engineering Conference (UPEC). London: IEEE, 2012, 1–6

[17]

Wu FZhang  XGodfrey K . Small signal stability analysis and optimal control of a wind turbine with doubly fed induction generator. IET Generation, Transmission & Distribution20071(5): 751–760 doi:10.1049/iet-gtd:20060395

[18]

Mei FPal  B C. Modal analysis of grid-connected doubly-fed induction generators. IEEE Transactions on Energy Conversion200722(3): 728–736

[19]

Ju PWu  FJin Y . Modelling and Control of Renewable Power Generation System. Beijing: Science Press, 2014 (in Chinese)

[20]

Trelea I. The particle swarm optimization algorithm: Convergence analysis and parameter selection. Information Processing Letters200385(6): 317–325