A low cost wearable optical-based goniometer for human joint monitoring

Chee Kian LIM, Zhiqiang LUO, I-Ming CHEN, Song Huat YEO

PDF(576 KB)
PDF(576 KB)
Front. Mech. Eng. ›› DOI: 10.1007/s11465-011-0201-7
RESEARCH ARTICLE

A low cost wearable optical-based goniometer for human joint monitoring

Author information +
History +

Abstract

Widely used in the fields of physical and occupational therapy, goniometers are indispensible when it comes to angular measurement of the human joint. In both fields, there is a need to measure the range of motion associated with various joints and muscle groups. For example, a goniometer may be used to help determine the current status of the range of motion in bend the arm at the elbow, bending the knee, or bending at the waist. The device can help to establish the range of motion at the beginning of the treatment series, and also allow the therapist to monitor progress during subsequent sessions. Most commonly found are the mechanical goniometers which are inexpensive but bulky. As the parts are mechanically linked, accuracy and resolution are largely limited. On the other hand, electronic and optical fiber-based goniometers promise better performance over its mechanical counterpart but due to higher cost and setup requirements does not make it an attractive proposition as well. In this paper, we present a reliable and non-intrusive design of an optical-based goniometer for human joint measurement. This device will allow continuous and long-term monitoring of human joint motion in everyday setting. The proposed device was benchmarked against mechanical goniometer and optical based motion capture system to validate its performance. From the empirical results, it has been proven that this design can be use as a robust and effective wearable joint monitoring device.

Keywords

optical / goniometer / human-joint measurement

Cite this article

Download citation ▾
Chee Kian LIM, Zhiqiang LUO, I-Ming CHEN, Song Huat YEO. A low cost wearable optical-based goniometer for human joint monitoring. Front Mech Eng, https://doi.org/10.1007/s11465-011-0201-7

References

[1]
Luinge H J, Veltink P H. Inclination measurement of human movement using a 3-D accelerometer with autocalibration. IEEE Transactions on Neural Systems and Rehabilitation Engineering, 2004, 12(1): 112–121
CrossRef Pubmed Google scholar
[2]
Veltink P H, Bussmann H B J, de Vries W, Martens W L J, Van Lummel R C. Detection of static and dynamic activities using uniaxial accelerometers. IEEE Transactions on Rehabilitation Engineering, 1996, 4(4): 375–385
CrossRef Pubmed Google scholar
[3]
Steele B G, Belza B, Cain K, Warms C, Coppersmith J, Howard J. Bodies in motion: monitoring daily activity and exercise with motion sensors in people with chronic pulmonary disease. Journal of Rehabilitation Research and Development, 2003, 40(5s): 45–58
CrossRef Pubmed Google scholar
[4]
Norkin C C, White D J. Measurement of joint motion a guide to goniometery. Philadelphia: FA Davis Company, 1995.
[5]
Reese N B, Bandy W D. Joint range of motion and muscle length testing. Saunders, 2002.
[6]
Electrogoniometer. http://www.biometricsltd.com/gonio.htm
[7]
Optical fiber based goniometer. http://www.adinstruments.com/products/hardware/research/product/MLTS700
[8]
Gibbs P T, Asada H H. Wearable conductive fiber sensors for multi-axis human joint angle measurements. Journal of Neuro-engineering and Rehabilitation, 2005, 2(1): 7
[9]
Legnani G, Zappa B, Casolo F, Adamini R, Magnani P L. A model of an electro-goniometer and its calibration for biomechanical applications. Medical Engineering & Physics, 2000, 22(10): 711–722
CrossRef Pubmed Google scholar
[10]
Donno M, Palange E, Di Nicola F, Bucci G, Ciancetta F. A new flexible optical fiber goniometer for dynamic angular, measurements: application to human joint movement monitoring. IEEE Transactions on Instrumentation and Measurement, 2008, 57(8): 1614–1620
CrossRef Google scholar
[11]
Shiratsu A, Coury H J C G. Reliability and accuracy of different sensors of a flexible electrogoniometer. Clinical Biomechanics (Bristol, Avon), 2003, 18(7): 682–684
CrossRef Pubmed Google scholar
[12]
Ng T W, Ang K T. The optical mouse for vibratory motion sensing. Sensors and Actuators. A, Physical, 2004, 116(2): 205–208
CrossRef Google scholar
[13]
Palacin J, Valganon I, Pernia R. The optical mouse for indoor mobile robot odometry measurement. Sensors and Actuators. A, Physical, 2006, 126(1): 141–147
CrossRef Google scholar
[14]
Minoni U, Signorini A. Low-cost optical motion sensors: An experimental characterization. Sensors and Actuators. A, Physical, 2006, 128(2): 402–408
CrossRef Google scholar
[15]
Tresanchez M, Palleja T, Teixido M, Palacin J. Using the image acquisition capabilities of the optical mouse sensor to build an absolute rotary encoder. Sensors and Actuators. A, Physical, 2010, 157(1): 161–167
CrossRef Google scholar
[16]
Morrey B F. 2nd ed.The Elbow and Its Disorders.Philadelphia: W. B. Saunders, 2000, 43–60
[17]
Fuss F K. The ulnar collateral ligament of the human elbow joint. Anatomy, function and biomechanics. Journal of Anatomy, 1991, 175: 203–212
Pubmed
[18]
Zatsiorsky V M, ed. Kinetics of Human Motion. Champaign, IL, Human Kinetics, 2002, 298–301

Acknowledgments

This work was supported in part by the Media Development Authority, Singapore under NRF IDM004-005 Grant and Agency for Science, Technology and Research, Singapore, under Astar-NKTH Singapore Hungary Joint Research Project SERC Grant 0521180050. The authors would like to thank and acknowledge the contributions and assistance rendered by Mr. Ong Chung Huar and Mr. Li Kang in this work.

RIGHTS & PERMISSIONS

2014 Higher Education Press and Springer-Verlag Berlin Heidelberg
AI Summary AI Mindmap
PDF(576 KB)

Accesses

Citations

Detail

Sections
Recommended

/