Axial compression behavior and analytical method of L-shaped column composed of concrete-filled square steel tubes

Bin Rong , Zhihua Chen , Fafitis Apostolos , Nan Yang

Transactions of Tianjin University ›› 2012, Vol. 18 ›› Issue (3) : 180 -187.

PDF
Transactions of Tianjin University ›› 2012, Vol. 18 ›› Issue (3) : 180 -187. DOI: 10.1007/s12209-012-1766-x
Article

Axial compression behavior and analytical method of L-shaped column composed of concrete-filled square steel tubes

Author information +
History +
PDF

Abstract

Based on the characteristics of an L-shaped column composed of concrete-filled square steel tubes, the axial compression experiment and nonlinear finite element analysis were carried out to study the mechanical property of the L-shaped column. The load-displacement curve for the L-shaped column, the deflection and load-strain curves for the mono columns were obtained by the axial compression experiment. The results show that the L-shaped column exhibits a flexural-torsional buckling failure mode. The numerical simulation by the finite element analysis shows that the bearing capacity and failure mode are in accordance with those of the axial compression experiment and the feasibility of the finite element analysis is proved. For the calculation of the bearing capacity of the L-shaped column composed of concrete-filled square steel tubes, an analytical method is proposed based on the theory of the elastic stability and spatial truss model. The results of the analytical method are in good agreement with those of the axial compression experiment and the finite element analysis.

Keywords

L-shaped column / concrete-filled square steel tube / axial compression experiment / finite element analysis / analytical method

Cite this article

Download citation ▾
Bin Rong, Zhihua Chen, Fafitis Apostolos, Nan Yang. Axial compression behavior and analytical method of L-shaped column composed of concrete-filled square steel tubes. Transactions of Tianjin University, 2012, 18(3): 180-187 DOI:10.1007/s12209-012-1766-x

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

Li W., Han L. H. Seismic performance of CFST column to steel beam joints with RC slab: Analysis[J]. Journal of Constructional Steel Research, 2011, 67(1): 127-139.

[2]

Uy B., Tao Z., Han L. H. Behavior of short and slender concrete-filled stainless steel tubular columns[J]. Journal of Constructional Steel Research, 2011, 67(3): 360-378.

[3]

Yang Y. F., Han L. H. Behavior of concrete-filled steel tubular (CFST) stub columns under eccentric partial compression[J]. Thin-Walled Structures, 2011, 49(2): 379-395.

[4]

Zhao H. L., Kunnath S. K., Han L. H. Simplified nonlinear response simulation of composite steel-concrete beams and CFST columns[J]. Engineering Structures, 2010, 32(9): 2825-2831.

[5]

Han L. H., Wang W. H., Yu H. X. Experimental behavior of reinforced concrete (RC) beam to concrete-filled steel tubular (CFST) column frames subjected to ISO-834 standard fire[J]. Engineering Structures, 2010, 32(10): 3130-3144.

[6]

Ellobody E., Young B. Nonlinear analysis of concrete-filled steel SHS and RHS columns[J]. Thin-Walled Structures, 2006, 44(8): 919-930.

[7]

China Engineering Construction Standardization Association. CECS 159: 2004, Technical Specification for Structures with Concrete-Filled Rectangular Steel Tube Members[ S]. 2004, Beijing, China: China Planning Press.

[8]

Leonard S., George F. Applied Structural Steel Design[M]. 2005, Beijing, China: Tsinghua University Press.

[9]

Chen Z. H., Rong B., Apostolos F. Axial compression stability of a crisscross section column composed of concretefilled square steel tubes[J]. Journal of Mechanics of Materials and Structures, 2009, 4(10): 1787-1799.

AI Summary AI Mindmap
PDF

140

Accesses

0

Citation

Detail

Sections
Recommended

AI思维导图

/