Wave motion of smoke in subway fire environment

Wenzhong Wu , Shijun You

Transactions of Tianjin University ›› 2009, Vol. 15 ›› Issue (3) : 206 -209.

PDF
Transactions of Tianjin University ›› 2009, Vol. 15 ›› Issue (3) : 206 -209. DOI: 10.1007/s12209-009-0036-z
Article

Wave motion of smoke in subway fire environment

Author information +
History +
PDF

Abstract

Wave motion in subway or tunnel fire is an intrinsic property of smoke. As the pressure of smoke changes with mass of certain power, a kind of linear wave equation for smoke can be derived from the conservation equations of its mass and momentum, under nearly homogeneous zone assumption. The smoke movement of 4 subway fires was simulated with Airpak. By fitting the pressure-mass functions to the simulated data, wave equations of the smoke were derived, and wave motions of smoke were thus validated. It can be seen that smoke wave is a kind of mass wave, whose velocity is inversely proportional to smoke mass, and wave of a bigger fire propagates slower.

Keywords

subway fire environment / smoke movement / wave propagation

Cite this article

Download citation ▾
Wenzhong Wu, Shijun You. Wave motion of smoke in subway fire environment. Transactions of Tianjin University, 2009, 15(3): 206-209 DOI:10.1007/s12209-009-0036-z

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

Lu Shichang. Performance Test Report of Smoke-Control at Nanlou Station of Tianjin Subway [R]. 2006, Tianjin: National Fire Engineer Technology Centre.

[2]

Lee S. R., Ryou H. Sun. A numerical study on smoke movement in longitudinal ventilation tunnel fires for different aspect ratio[J]. Building and Environment, 2006, 41(2): 719-725.

[3]

Lonnermark Lon A, Ingason H. Acoustic considerations regarding pulsations during large-scale fire tests in a tunnel [C]. In: Proceedings of the Eighth International Symposium on Fire Safety Science. Beijing, 2005. 18–23.

[4]

Lonnermark L. A., Persson B., Ingason H. Pulsations during large-scale fire tests in the Runehamar tunnel[J]. Fire Safety Journal, 2006, 41(4): 377-389.

[5]

Lu Y., Ma Z., Zou Pinghua. Heating, Ventilation and Air Conditioning[M]. 2002, Beijing: China Architecture and Build ing Press.

[6]

Yang Q., Pu Baorong. Advanced Heat Transfer[M]. 2001, Shanghai: Shanghai Jiao Tong University Press.

[7]

Dong Shuyun. Piston Effect on Subway Station and Its Utilization in the North of China [D]. 2008, Tianjin: Tianjin University.

[8]

Ruan Fengdong. Energy Saving Technology Research of Intelligent Subway Ventilation and Air Conditioning System [D]. 2006, Tianjin: Tianjin University.

[9]

Wei Qiaoli. VAV Application in the Subway Environmental Control System [D]. 2005, Tianjin: Tianjin University.

[10]

Na Yanling. CFD Simulation and Experiment for Ventilation, Fire in Subway [D]. 2003, Tianjin: Tianjin University.

[11]

The Third Railway Survey and Design Institute of China. Feasibility Study Report of Tianjin Subway Line 1 [R]. Tianjin, 2001(in Chinese).

[12]

Shanghai Road and Rail Tunnel Design Institute. Environmental Control System Outline Design Report for Check of Tianjin Subway Line 1 [R]. Shanghai, 2001(in Chinese).

[13]

Zhang T., Chen Q. Novel air distribution systems for commercial aircraft cabins[J]. Building and Environment, 2007, 42(1): 1675-1684.

[14]

Xu W., Gong Li. Encyclopedia of China[M]. 2000, Beijing: The Encyclopedia of China Publishing House.

[15]

Whitham G. B. Lectures on Wave Propagation[M]. 1979, Berlin: Springer Press.

AI Summary AI Mindmap
PDF

128

Accesses

0

Citation

Detail

Sections
Recommended

AI思维导图

/