High density collinear holographic data storage system

Xiaodi TAN, Xiao LIN, An’an WU, Jingliang ZANG

PDF(1654 KB)
PDF(1654 KB)
Front. Optoelectron. ›› 2014, Vol. 7 ›› Issue (4) : 443-449. DOI: 10.1007/s12200-014-0399-1
REVIEW ARTICLE
REVIEW ARTICLE

High density collinear holographic data storage system

Author information +
History +

Abstract

Holographic data storage system (HDSS) has been a good candidate for a volumetric recording technology, due to their large storage capacities and high transfer rates, and have been researched for tens of years after the principle of holography was first proposed. However, these systems, called conventional 2-axis holography, still have essential issues for commercialization of products. Collinear HDSS, in which the information and reference beams are modulated co-axially by the same spatial light modulator (SLM), as a new read/write method for HDSS are very promising. With this unique configuration, the optical pickup can be designed as small as DVDs, and can be placed on one side of the recording media (disc). In the disc structure, the preformatted reflective layer is used for the focus/tracking servo and reading address information, and a dichroic mirror layer is used for detecting holographic recording information without interfering with the preformatted information. A 2-dimensional digital page data format is used and the shift-multiplexing method is employed to increase recording density. As servo technologies are being introduced to control the objective lens to be maintained precisely to the disc in the recording and reconstructing process, a vibration isolator is no longer necessary. Collinear holography can produce a small, practical HDSS more easily than conventional 2-axis holography. In this paper, we introduced the principle of the collinear holography and its media structure of disc. Some results of experimental and theoretical studies suggest that it is a very effective method. We also discussed some methods to increase the recording density and data transfer rates of collinear holography.

Keywords

holographic data storage system (HDSS) / holography / optical memory / volumetric recording / optical disc / high density recording

Cite this article

Download citation ▾
Xiaodi TAN, Xiao LIN, An’an WU, Jingliang ZANG. High density collinear holographic data storage system. Front. Optoelectron., 2014, 7(4): 443‒449 https://doi.org/10.1007/s12200-014-0399-1

References

[1]
van Heerden P J. Theory of optical information storage in solids. Applied Optics, 1963, 2(4): 393–400
CrossRef Google scholar
[2]
Mok F H. Angle-multiplexed storage of 5000 holograms in lithium niobate. Optics Letters, 1993, 18(11): 915–917
CrossRef Pubmed Google scholar
[3]
Denz C, Pauliat G, Roosen G, Tschudi T. Volume hologram multiplexing using a deterministic phase encoding method. Optics Communications, 1991, 85(2–3): 171–176
CrossRef Google scholar
[4]
Lande D, Heanue J F, Catrysse P, Bashaw M C, Hesselink L. Digital wavelength-multiplexed holographic data storage system. In: Summaries of papers presented at the Conference onLasers and Electro-Optics. 1996, 142–143
[5]
Horimai H, Tan X. Collinear technology for a holographic versatile disk. Applied Optics, 2006, 45(5): 910–914
CrossRef Pubmed Google scholar
[6]
Horimai H, Tan X. Advanced collinear holography. Optical Review, 2005, 12(2): 90–92
CrossRef Google scholar
[7]
Horimai H, Tan X. Holographic versatile disc system. In: Proceedings of SPIE, Organic Holographic Materials and Applications III, San Diego. 2005, 5939: 593901-1–593901-9
[8]
Kang Y H, Kim K H, Lee B. Volume hologram scheme using optical fiber for spatial multiplexing. Optics Letters, 1997, 22(10): 739–741
[9]
Tan X, Matoba O, Shimura T, Kuroda K. Improvement in holographic storage capacity by use of double-random phase encryption. Applied Optics, 2001, 40(26): 4721–4727
CrossRef Pubmed Google scholar
[10]
Psaltis D, Levene M, Pu A, Barbastathis G, Curtis K. Holographic storage using shift multiplexing. Optics Letters, 1995, 20(7): 782–784
CrossRef Pubmed Google scholar
[11]
Horimai H, Tan X, Li J. Collinear holography. Applied Optics, 2005, 44(13): 2575–2579
CrossRef Pubmed Google scholar
[12]
Li J, Cao L, Gu H, Tan X, He Q, Jin G. Orthogonal-reference-pattern-modulated shift multiplexing for collinear holographic data storage. Optics Letters, 2012, 37(5): 936–938
CrossRef Pubmed Google scholar
[13]
Ogasawara Y, Kawano K, Haga K, Minabe J, Yasuda S, Furuki M, Hayashi K, Yoshizawa H. High-pass filtering in coaxial holographic data storage. Japanese Journal of Applied Physics, 2007, 46(6B 6s): 3828–3831
CrossRef Google scholar
[14]
Lin X, Xiao X, Wu A, Tan X. An effective phase modulation in the collinear holographic storage. In: Proceedings of SPIE, Practical Holography XXVIII: Materials and Applications, San Francisco. 2014, 9006: 9006-1–9006-6

RIGHTS & PERMISSIONS

2014 Higher Education Press and Springer-Verlag Berlin Heidelberg
AI Summary AI Mindmap
PDF(1654 KB)

Accesses

Citations

Detail

Sections
Recommended

/