Simultaneous acquisition of CT angiography and whole brain CT perfusion images by using multiphase dynamic helical scan on 16 MDCT
Received date: 29 Sep 2008
Accepted date: 07 Jan 2009
Published date: 05 Jun 2009
Copyright
We implemented a new protocol — multiphase dynamic helical scan to acquire CT angiography (CTA) and whole brain CT perfusion (CTP) images simultaneously with single scan on 16 multidetector CT (MDCT). A total of 90 patients who were randomly assigned into 3 groups were included in our study. Each group underwent CT scan by using the new protocol, traditional CTA and CTP protocol, respectively. The image quality of CTA, the CTP parameter values and the X-ray doses were measured and compared between the new protocol and the traditional protocols. There was no statistically significant difference in the CTA image quality between the above methods (P=0.55). For CTP parameters, the new protocol tended to overestimate the blood volume (BV) and blood flow (BF) value, and to underestimate the mean transit time (MTT) value compared with the traditional method. However, there was no statistically significant difference in BV, BF, and MTT value between the two methods except permeability surface (PS) (P>0.05). The volume CT dose index (CTDIvol) and dose length product (DLP) of our protocol were lower than the traditional one. The new protocol can obtain valuable diagnostic information in a shorter time without significant compromise in image quality. In addition, it reduces the radiation dose as well as contrast medium usage on the patient.
Weiwei CHEN , Jianpin QI , Wenzhen ZHU , Wenhua HUANG , Jinmei SONG . Simultaneous acquisition of CT angiography and whole brain CT perfusion images by using multiphase dynamic helical scan on 16 MDCT[J]. Frontiers of Medicine, 2009 , 3(2) : 230 -235 . DOI: 10.1007/s11684-009-0023-8
1 |
XueJ,GaoP,WangX,LiaoX,WangY,WangY. Ischemic lesion typing on computed tomography perfusion and computed tomography angiography in hyperacute ischemic stroke: a preliminary study. Neurol Res, 2008, 30(4): 337-340
|
2 |
ParsonsM W. Perfusion CT: is it clinically useful? Int J Stroke, 2008, 3(1): 41-50
|
3 |
ScaroniR,TambascoN,CardaioliG,ParnettiL,PaloniF,BorangaB,PelliccioliG P. Multimodal use of computed tomography in early acute stroke, part 2. Clin Exp Hypertens, 2006, 28(3,4): 427-431
|
4 |
MurphyB D,FoxA J,LeeD H,SahlasD J,BlackS E,HoganM J,CouttsS B,DemchukA M,GoyalM,AvivR I,SymonsS,GulkaI B,BeletskyV,PelzD,HachinskiV,ChanR,LeeT Y. Identification of penumbra and infarct in acute ischemic stroke using computed tomography perfusion-derived blood flow and blood volume measurements. Stroke, 2006, 37(7): 1771-1777
|
5 |
ZhangQ B,FengX Y,HeH J,JiangB D. Multi-slice helical CT perfusion imaging in evaluating intracranial neoplasms and tumor-like lesions. Zhonghua Zhong Liu Za Zhi, 2007, 29(2): 131-135 (in Chinese)
|
6 |
CianfoniA,ColosimoC,BasileM,WintermarkM,BonomoL. Brain perfusion CT: principles, technique and clinical applications. Radiol Med, 2007, 112(8): 1225-1243
|
7 |
SchrammP. High-concentration contrast media in neurological multidetector-row CT applications: implications for improved patient management in neurology and neurosurgery. Neuroradiology, 2007, 49(Suppl1): S35-45
|
8 |
EastwoodJ D,LevM H,AzhariT,LeeT Y,BarboriakD P,DelongD M,FitzekC,HerzauM,WintermarkM,MeuliR,BrazierD,ProvenzaleJ M. CT perfusion scanning with deconvolution analysis: pilot study in patients with acute middle cerebral artery stroke. Radiology, 2002, 222(1): 227-236
|
9 |
ScharfJ,BrockmannM A,DaffertshoferM,DiepersM,Neumaier-ProbstE,WeissC,PaschkeT,GrodenC. Improvement of sensitivity and inter-rater reliability to detect acute stroke by dynamic perfusion computed tomography and computed tomography angiography. J Comput Assist Tomogr, 2006, 30(1): 105-110
|
10 |
RydbergJ,BuckwalterK A,CaldemeyerK S,PhillipsM D,ConcesD J Jr,AisenA M,PersohnS A,KopeckyK K. Multisection CT: Scanning Techniques and Clinical Applications. Radiographics, 2000, 20(6): 1787-1806
|
11 |
WintermarkM,FischbeinN J,SmithW S,KoN U,QuistM,DillonW P. Accuracy of dynamic perfusion CT with deconvolution in detecting acute hemispheric stroke. AJNR Am J Neuroradiol, 2005, 26(1): 104-112
|
12 |
SchrammP,SchellingerP D,KlotzE,KallenbergK,FiebachJ B,KülkensS,HeilandS,KnauthM,SartorK. Comparison of perfusion computed tomography and computed tomography angiography source images with perfusion-weighted imaging and diffusion-weighted imaging in patients with acute stroke of less than 6 hours’ duration. Stroke, 2004, 35(7): 1652-1658
|
13 |
YounS W,KimJ H,WeonY C,KimS H,HanM K,BaeH J. Perfusion CT of the brain using 40-mm-wide detector and toggling table technique for initial imaging of acute stroke. AJR Am J Roentgenol, 2008, 191(3): W120-126
|
14 |
LaghiA. Multidetector CT (64 Slices) of the liver: examination techniques. Eur Radiol, 2007, 17(3): 675-683
|
15 |
EastwoodJ D,LevM H,ProvenzaleJ M. Perfusion CT with iodinated contrast material. Am J Roentgenol, 2003, 180(1): 3-12
|
16 |
EzzeddineM A,LevM H,McDonaldC T,RordorfG,Oliveira-FilhoJ,AksoyF G,FarkasJ,SegalA Z,SchwammL H,GonzalezR G,KoroshetzW J. CT angiography with whole brain perfused blood volume imaging: added clinical value in the assessment of acute stroke. Stroke, 2002, 33(4): 959-966
|
17 |
LevM H,SegalA Z,FarkasJ,HossainS T,PutmanC,HunterG J,BudzikR, HarrisG J,BuonannoF S,EzzeddineM A,ChangY,KoroshetzW J,GonzalezR G,SchwammL H. Utility of perfusion-weighted CT imaging in acute middle cerebral artery stroke treated with intra-arterial thrombolysis: prediction of final infarct volume and clinical outcome. Stroke, 2001, 32(9): 2021-2028
|
18 |
DittrichR,AkdenizS,KloskaS P,FischerT,RitterM A,SeidenstickerP,HeindelW,RingelsteinE B,NabaviD G. Low rate of contrast-induced nephropathy after CT perfusion and CT angiography in acute stroke patients. J Neurol, 2007, 254(11): 1491-1497
|
19 |
RobertsH C,RobertsT P,SmithW S,LeeT J,FischbeinN J,DillonW P.Multisection dynamic CT perfusion for acute cerebral ischemia: the "toggling-table" technique. Am J Neuroradiol, 2001, 22(6): 1077-1080
|
20 |
WintermarkM,SmithW S,KoN U,QuistM,SchnyderP,DillonW P. Dynamic perfusion CT: optimizing the temporal resolution and contrast volume for calculation of perfusion CT parameters in stroke patients. Am J Neuroradiol, 2004, 25(5): 720-729
|
/
〈 |
|
〉 |