Stormwater runoff pollution loads from an urban catchment with rainy climate in China

Liqing LI , Baoqing SHAN , Chenqing YIN

Front. Environ. Sci. Eng. ›› 2012, Vol. 6 ›› Issue (5) : 672 -677.

PDF (157KB)
Front. Environ. Sci. Eng. ›› 2012, Vol. 6 ›› Issue (5) : 672 -677. DOI: 10.1007/s11783-012-0447-2
RESEARCH ARTICLE
RESEARCH ARTICLE

Stormwater runoff pollution loads from an urban catchment with rainy climate in China

Author information +
History +
PDF (157KB)

Abstract

An older urban district in Wuhan, China, is transitioning from discharging sewage and stormwater directly into lakes, to directing the sewage to wastewater treatment plants (WWTPs). Dealing with polluted stormwater discharge is a great challenge. Stormwater runoff from an urban catchment with a combined sewer system was sampled and analyzed over a three-year period. Results indicate that wet weather flows account for 66%, 31%, 17%, and 13% of the total load of suspended solids (SS), chemical oxygen demand (COD), total nitrogen, and total phosphorus, respectively. The first flush of COD and SS was significant in all runoff events. More than 50% of the SS and COD loads were transported by the first 30% of runoff volume. Storage and treatment of the first 10 mm from each combined sewer overflow event could reduce more than 70% of the annual COD overflow load. An integrated solution is recommended, consisting of a tank connected to the WWTP and a detention pond, to store and treat the combined sewer overflow (CSO). These results may be helpful in mitigating CSO pollution for many other urban areas in China and other developing countries.

Keywords

combined sewer overflow / pollution load / first flush / detention basins

Cite this article

Download citation ▾
Liqing LI, Baoqing SHAN, Chenqing YIN. Stormwater runoff pollution loads from an urban catchment with rainy climate in China. Front. Environ. Sci. Eng., 2012, 6(5): 672-677 DOI:10.1007/s11783-012-0447-2

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

Novotny V. Integrating diffuse/nonpoint pollution control and water body restoration into watershed management. Journal of the American Water Resources Association, 1999, 35(4): 717–727

[2]

Taebi A, Droste R L. Pollution loads in urban runoff and sanitary wastewater. Science of the Total Environment, 2004, 327(1–3): 175–184

[3]

Gnecco I, Berretta C, Lanza L G, La Barbera P. Storm water pollution in the urban environment of Genoa, Italy. Atmospheric Research, 2005, 77(1–4): 60–73

[4]

Suárez J, Puertas J. Determination of COD, BOD, and suspended solids loads during combined sewer overflow (CSO) events in some combined catchments in Spain. Ecological Engineering, 2005, 24(3): 199–219

[5]

Kim G H, Yur J H, Kim J K. Diffuse pollution loading from urban stormwater runoff in Daejeon City, Korea. Journal of Environmental Management, 2007, 85(1): 9–16

[6]

Chebbo G, Gromaire M C, Ahyerre M, Garnaud S. Production and transport of urban wet weather pollution in combined sewer systems: the “Marais” experimental urban catchment in Paris. Urban Water, 2001, 3(1–2): 3–15

[7]

Brombach H, Weiss G, Fuchs S. A new database on urban runoff pollution: comparison of separate and combined sewer systems. Water Science and Technology, 2005, 51(2): 119–128

[8]

Adams W R, Thackston E L, Speece R E. Modeling CSO impacts from Nashville using EPA’s demonstration approach. Journal of Environmental Engineering, 1997, 123(2): 126–133

[9]

Even S, Mouchel J M, Servais P, Flipo N, Poulin M, Blanc S, Chabanel M, Paffoni C. Modelling the impacts of combined sewer overflows on the river Seine water quality. Science of the Total Environment, 2007, 375(1–3): 140–151

[10]

Seidl M, Huang V, Mouchel J M. Toxicity of combined sewer overflows on river phytoplankton: the role of heavy metals. Environmental Pollution, 1998, 101(1): 107–116

[11]

Bilotta G S, Brazier R E. Understanding the influence of suspended solids on water quality and aquatic biota. Water Research, 2008, 42(12): 2849–2861

[12]

Arnold E G, Lenore S C, Andrew D E. Standard Methods for the Examination of Water and Wastewater. 20th ed. Washington DC, USA: American Public Health Association, American Water Works Association, Water Pollution Control Federation, 1998

[13]

Ebina J, Tsutsui T, Shirai T. Simultaneous determination of total nitrogen and total phosphorus in water using peroxodisulfate oxidation. Water Research, 1983, 17(12): 1721–1726

[14]

Sansalone J J, Buchberger S G. Partitioning and first flush of metals in urban roadway stormwater. Journal of Environmental Engineering, 1997, 123(2): 134–143

[15]

U.S. Environmental Protection Agency (USEPA). Results of the National Wide Urban Runoff Program Volume I—Final Report. Washington, DC: Water Planning Division, U.S. Government Printing Office, 1983

[16]

Sztruhár D, Sokác M, Holiencin A, Markovic A. Comprehensive assessment of combined sewer overflows in Slovakia. Urban Water, 2002, 4(3): 237–243

[17]

Ashley R M, Fraser A, Burrows R, Blandsby J. The management of sediment in combined sewers. Urban Water, 2000, 2(4): 263–275

[18]

Gromaire M C, Garnaud S, Saad M, Chebbo G. Contribution of different sources to the pollution of wet weather flows in combined sewers. Water Research, 2001, 35(2): 521–533

[19]

Chebbo G, Ashley R, Gromaire M C. The nature and pollutant role of solids at the water-sediment interface in combined sewer networks. Water Science and Technology, 2003, 47(4): 1–10

[20]

Kafi M, Gasperi J, Moilleron R, Gromaire M C, Chebbo G. Spatial variability of the characteristics of combined wet weather pollutant loads in Paris. Water Research, 2008, 42(3): 539–549

[21]

Gasperi J, Gromaire M C, Kafi M, Moilleron R, Chebbo G. Contributions of wastewater, runoff and sewer deposit erosion to wet weather pollutant loads in combined sewer systems. Water Research, 2010, 44(20): 5875–5886

[22]

Lee J G, Heaney J P, Lai F H. Optimization of integrated urban wet-weather control strategies. Journal of Water Resources Planning and Management, 2005, 131(4): 307–315

[23]

Lau K T, Butler D, Schütze M. Is combined sewer over overflow spill frequency/volume a good indicator of receiving water quality impact? Urban Water, 2002, 4(2): 181–189

[24]

Calabrò P S, Viviani G. Simulation of the operation of detention tanks. Water Research, 2006, 40(1): 83–90

RIGHTS & PERMISSIONS

Higher Education Press and Springer-Verlag Berlin Heidelberg

AI Summary AI Mindmap
PDF (157KB)

3146

Accesses

0

Citation

Detail

Sections
Recommended

AI思维导图

/