Abstract
Reverse osmosis system with the disc-tube module (DT-RO) was applied to treat landfill leachate on full scale at the Changshengqiao Sanitary Landfill, Chongqing City, China. In the first six-mouth operation phase, the treatment performance of DT-RO system had been excellent and stable. The removal rate of chemical oxygen demand (COD), total organic carbon (TOC), electrical conductivity (EC), and ammonia nitrogen (NH3-N) reached 99.2–99.7%, 99.2%, 99.6%, and over 98%, respectively. The rejection of Ca2+, Ba2+, and Mg2+ was over 99.9%, respectively. Suspended solid (SS) was not detected in product water. Effective methods had been adopted to control membrane fouling, of which chemical cleaning is of utmost importance to guarantee the long smooth operation of the DT-RO system. The DT-RO system is cleaned in turns with Cleaner A and Cleaner C. At present, the 1st stage cleaning cycle by Cleaner A and Cleaner C is conducted every 100 and 500 h, respectively, depending on raw the water quality.
Keywords
Disc-tube reverse osmosis (DT-RO), landfill leachate, performance, chemical cleaning
Cite this article
Download citation ▾
WANG Baozhen, LIU Shuo, LIU Yanping, LI Xiujin.
Performance of landfill leachate treatment system
with disc-tube reverse osmosis units.
Front. Environ. Sci. Eng., 2008, 2 (1) : 24-31 DOI:10.1007/s11783-008-0024-x
CHANGE HISTORY
A Correction to this paper has been published:
https://doi.org
The Retraction Note was updated to reflect reception of statements of disagreement from all authors.
This article has been retracted.Please see the Retraction Notice for more detail:
https://doi.org