Design of temperature insensitive in vivo strain sensor using multilayer single mode optical fiber

F. MAKOUEI, S. MAKOUEI

PDF(225 KB)
PDF(225 KB)
Front. Optoelectron. ›› 2016, Vol. 9 ›› Issue (4) : 621-626. DOI: 10.1007/s12200-016-0537-z
RESEARCH ARTICLE
RESEARCH ARTICLE

Design of temperature insensitive in vivo strain sensor using multilayer single mode optical fiber

Author information +
History +

Abstract

Bone strain measurement is a case of interest and demanding task for osteogenic adaption responses. In this paper, a novel biocompatible optical sensor for the bone axial strain measurement was proposed. In case modern multilayer single mode WII type optical fibers are well designed, they exhibit superior characteristics compared to conventional metal strain gauges (SGs). Furthermore, they could be strong competitors for SGs based on fiber Bragg grating (FBG) devices. In this study, mode field diameter (MFD) was selected as the indirect parameter for sensing task, which was totally a new approach. The strain sensitivity of 70.7733 pm/µε was obtained. Moreover, temperature sensitivity was –3.0031 × 106 pm/°C, which was negligible and removed the temperature compensation complexity for the sensor structure presented. The satisfactory property achieved for the designed sensor is as a result of multilayer fiber’s complicated structure as well as the design procedure based on evolutionary genetic algorithm (GA). In addition, the sensor demonstrated a reliable performance as its sensitivity was independent of the magnitude of the applied load.

Keywords

bone strain / in vivo / optical strain gauge (SG) / genetic algorithm (GA)

Cite this article

Download citation ▾
F. MAKOUEI, S. MAKOUEI. Design of temperature insensitive <?A3B2 tf="Arial Bold Italic (TrueType)"?>in vivo strain sensor using multilayer single mode optical fiber. Front. Optoelectron., 2016, 9(4): 621‒626 https://doi.org/10.1007/s12200-016-0537-z

References

[1]
Bekker A, Cloete T J, Chinsamy-Turan A, Nurick G N, Kok S. Constant strain rate compression of bovine cortical bone on the Split-Hopkinson Pressure Bar. Materials Science and Engineering C, 2015, 46: 443–449
CrossRef Pubmed Google scholar
[2]
Yang P F, Brüggemann G P, Rittweger J. What do we currently know from in vivo bone strain measurements in humans? Musculoskeletal & Neuronal Interact, 2011, 11(1): 8–20
Pubmed
[3]
Fresvig T, Ludvigsen P, Steen H, Reikerås O. Fibre optic Bragg grating sensors: an alternative method to strain gauges for measuring deformation in bone. Medical Engineering & Physics, 2008, 30(1): 104–108
CrossRef Pubmed Google scholar
[4]
Roriz P, Carvalho L, Frazão O, Santos J L, Simões J A. From conventional sensors to fibre optic sensors for strain and force measurements in biomechanics applications: a review. Journal of Biomechanics, 2014, 47(6): 1251–1261
CrossRef Pubmed Google scholar
[5]
Othonos A. Fiber Bragg gratings. Journal of Scientific Instruments, 1997, 68(12): 4309–4341
CrossRef Google scholar
[6]
Reekie L, Dakin J P, Archambault J L, Xu M G. Discrimination between strain and temperature effects using dual-wavelength fiber grating sensors. Electronics Letters, 1994, 30(13): 1085–1087
CrossRef Google scholar
[7]
Liu H B, Liu H Y, Peng G D, Chu P L. Strain and temperature sensor using a combination of polymer and silica fibre Bragg gratings. Optics Communications, 2003, 219(1-6): 139–142
CrossRef Google scholar
[8]
Holland J H. Adaptation in Natural and Artificial Systems. 4th ed. Cambridge, MA: MIT Press, 1992
[9]
Goldberg D E. Genetic Algorithms in Search, Optimization and Machine Learning. New York: Addison-Wesley, 1989
[10]
Zhang X, Tian X. Analyzes of waveguide dispersion characteristics of WI- and WII-type triple-clad single-mode fibers. Optics & Laser Technology, 2003, 35(4): 237–244
CrossRef Google scholar
[11]
Makouei S, Oskouei M S, Rostami A. Study of bending loss and mode field diameter in depressed inner core triple clad single mode optical fibers. Optics Communications, 2007, 280(1): 58–67
CrossRef Google scholar
[12]
Gatak A, Thyagarajan K. Introduction to Fiber Optics. 3rd ed. Cambridge: Cambridge University Press, 2002
[13]
Artiglia M, Coppa G, Di Vita P, Potenza M, Sharma A. Mode field diameter measurements in single mode optical fibers. IEEE Journal of Lightwave Technology, 1989, 7(8): 1139–1152
CrossRef Google scholar
[14]
Mishra V, Singh N, Rai D V, Tiwari U, Poddar G C, Jain S C, Mondal S K, Kapur P. Fiber Bragg grating sensor for monitoring bone decalcification. Orthopeadics & Traumatology, Surgery & Research, 2010, 96(6): 646–651
CrossRef Google scholar
[15]
Mignani A G, Baldini F. Biomedical sensors using optical fibres. Reports on Progress in Physics, 1996, 59(1): 1–28
CrossRef Google scholar
[16]
Cai J, Ishikawa Y, Wada K. Strain induced bandgap and refractive index variation of silicon. Optics Express, 2013, 21(6): 7162–7170
CrossRef Pubmed Google scholar
[17]
Ghosh G. Temperature dispersion of refractive indexes in some silicate fiber glasses. Photonics Technology Letters, 1994, 6(3): 431–433
CrossRef Google scholar
[18]
Ghosh G. Dispersion of temperature coefficients of birefringence in some chalcopyrite crystals. Applied Optics, 1984, 23(7): 976–978
CrossRef Pubmed Google scholar

RIGHTS & PERMISSIONS

2016 Higher Education Press and Springer-Verlag Berlin Heidelberg
AI Summary AI Mindmap
PDF(225 KB)

Accesses

Citations

Detail

Sections
Recommended

/