Behavior of axially loaded square concrete-filled tailor-welded steel tubular and concrete-filled cold-formed steel tubular stub columns

Wangxi ZHANG , Weilei LV , Shuntao LI , Weijian YI

ENG. Struct. Civ. Eng ››

PDF (23419KB)
ENG. Struct. Civ. Eng ›› DOI: 10.1007/s11709-026-1376-7
RESEARCH ARTICLE
Behavior of axially loaded square concrete-filled tailor-welded steel tubular and concrete-filled cold-formed steel tubular stub columns
Author information +
History +
PDF (23419KB)

Abstract

Variations in cross-sectional area, corner geometry, and steel material properties lead to distinct axial compressive behaviors and influence the design of concrete-filled tailor-welded steel tubular (CFTWST) and concrete-filled cold-formed steel tubular (CFCFST) stub members. Few studies have systematically examined this topic. This paper compares the behavior and design of CFTWST and CFCFST square stubs under axial compression. Fourteen stub columns were tested under axial compression, and Digital Image Correlation method was adopted to obtain full-field deformation measurements. The test focused on the load–displacement relationship, transverse strain development, and failure modes. The key experimental parameters included concrete strength, steel strength, and the width-to-thickness ratio of the steel tube (B/t). A validated finite element (FE) model was used for parametric analysis to supplement test results. Findings show that when B/t ≤ 30, CFCFST’s load-bearing capacity exceeds CFTWST by > 5% (max 25% for C30, B/t = 16.7, Q235 specimens). Additionally, square CFCFST stub specimens exhibit superior concrete confinement by the steel tube and stronger steel-concrete interaction compared to square CFTWST stub specimens. Design formulas for square CFTWST and CFCFST stubs are proposed and validated against extensive experimental data (from this study and existing literature) as well as FE analysis.

Graphical abstract

Keywords

concrete-filled steel columns / axial compression / computational theory / FE model

Cite this article

Download citation ▾
Wangxi ZHANG, Weilei LV, Shuntao LI, Weijian YI. Behavior of axially loaded square concrete-filled tailor-welded steel tubular and concrete-filled cold-formed steel tubular stub columns. ENG. Struct. Civ. Eng DOI:10.1007/s11709-026-1376-7

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

GB 50936-2014. Technical Code for Concrete Filled Steel Tubular Structures. Beijing: China Architecture & Building Press, 2014 (in Chinese)

[2]

Han L H. Concrete filled Steel Tubular Structures: Theory and Practice. 3rd ed. Beijing: Science Press, 2016 (in Chinese)

[3]

Young B , Ellobody E . Experimental investigation of concrete-filled cold-formed high strength stainless steel tube columns. Journal of Constructional Steel Research, 2006, 62(5): 484–492

[4]

Liu D L . Tests on high-strength rectangular concrete-filled steel hollow section stub columns. Journal of Constructional Steel Research, 2005, 61(7): 902–911

[5]

Han L H , Yang Y F. . Study on axial bearing capacity of concrete-filled-steel-tube columns with rectangular section.. China Civil Engineering Journal, 2001, 34(4): 22–31

[6]

Alqawzai S , Liu Z K , Wang D F , Liu M H , Yang B , Chen K , Guo Y X , Elchalakani M . Study on octagonal UHPCFDST stub columns subjected to concentric and eccentric compression. Journal of Constructional Steel Research, 2025, 232: 109637

[7]

Alqawzai S , Qui N T , Alawag A M , Elchalakani M , Yang B . Confinement-based design model and design-code assessment for axially-loaded hexagonal CFDST short columns. Journal of Constructional Steel Research, 2026, 241: 110284

[8]

Alqawzai S , Chen K , Shen L , Ding M , Yang B , Elchalakani M . Behavior of octagonal concrete-filled double-skin steel tube stub columns under axial compression. Journal of Constructional Steel Research, 2020, 170: 106115

[9]

Alqawzai S , Yang B , Chen K , Elchalakani M . Testing and strength prediction of polygonal UHPCFDST short columns under concentric and eccentric compression. Engineering Structures, 2025, 325: 119473

[10]

Ayough P , Ibrahim Z , Sulong N H R , Hsiao P C . The effects of cross-sectional shapes on the axial performance of concrete-filled steel tube columns. Journal of Constructional Steel Research, 2021, 176: 106424

[11]

Ibañez C , Hernández-Figueirido D , Piquer A . Shape effect on axially loaded high strength CFST stub columns. Journal of Constructional Steel Research, 2018, 147: 247–256

[12]

Gan D , Zhou Z , Zhou X H . Axially loaded thin-walled square concrete-filled steel tubes stiffened with diagonal binding ribs. ACI Structural Journal, 2019, 116(6): 265–280

[13]

Zhou Z , Zhou X H , Gan D , Liu Y J . Comparison and design of stiffened rectangular concrete-filled steel tubular members. Journal of Constructional Steel Research, 2023, 208: 108037

[14]

Zhou X H , Gan D , Liu J P , Chen Y F . Composite effect of stub square steel tubed columns under axial compression. Advanced Steel Construction, 2018, 14(2): 274–290

[15]

Li C , Wu W J , Luo X , He F Y , Hou M C . Shear behavior of outer interface in CE-CFST column strengthened with stud connector. Journal of Constructional Steel Research, 2026, 236: 110001

[16]

Zhu A Z , Zhang X W , Zhu H P , Zhu J H , Lu Y . Experimental study of concrete filled cold-formed steel tubular stub columns. Journal of Constructional Steel Research, 2017, 134: 17–27

[17]

Tao Z , Wang Z B , Han L H. . Behavior of rectangular cold-formed steel tubular columns filled with concrete.. Engineering Mechanics, 2006, 23(3): 147–155

[18]

Li Y Q , Li G W , Shen Z Y , Ma Y F , Zhu S W. . Modification method for yield strength of cold-formed thick-walled steel sections considering cold-forming effect.. Journal of Building Structures, 2015, 36(5): 1–7

[19]

Abdel-Rahman N , Sivakumaran K S . Material properties models for analysis of cold-formed steel members. Journal of Structural Engineering, 1997, 123(9): 1135–1143

[20]

Dassault Systèmes. Standard User’s Manual for ABAQUS Version 6.12. 2012

[21]

GB/T 228.1-2021. Metallic Materials—Tensile Testing—Part 1: Method of Test at Room Temperature. Beijing: Standards Press of China, 2021 (in Chinese)

[22]

Luo B F , Wu M , Zhang X B , Zhang P , Xiang P , Deng X H , Huo J S , Chen J , Xu S P . Axial compressive bearing capacity of high-strength concrete-filled Q690 square steel tubular stub column. Construction and Building Materials, 2024, 413: 134859

[23]

Zhou X J , Bai S M , Yuan H H , Liang J , Mou T M . Matching relationship study between steel ratio and core concrete strength in UHSCFST stub columns. Journal of Constructional Steel Research, 2024, 219: 108806

[24]

GB 50011-2010. Code for Seismic Design of Buildings. Beijing: China Architecture & Building Press, 2010 (in Chinese)

[25]

Thomas Telford. CEB-FIP Model Code 1990. London: Thomas Telford, 1991

[26]

Uy B . Strength of concrete filled steel box columns incorporating local buckling. Journal of Structural Engineering, 2000, 126(3): 341–352

[27]

Han L H . Tests on stub columns of concrete-filled RHS sections. Journal of Constructional Steel Research, 2002, 58(3): 353–372

[28]

Schneider S P . Axially loaded concrete-filled steel tubes. Journal of Structural Engineering, 1998, 124(10): 1125–1138

[29]

Du Y S , Chen Z H , Xiong M X . Experimental behavior and design method of rectangular concrete-filled tubular columns using Q460 high-strength steel. Construction and Building Materials, 2016, 125: 856–872

[30]

Liew J Y R, Xiong D X, Zhang M H. Experimental studies on concrete filled tubes with ultra-high strength materials. In: Proceedings of the 6th International Symposium on Steel Structures. Seoul: Korean Society of Steel Construction, 2011, 377–384

[31]

Hu H S , Lin K , Liu Y , Guo Z X. . Study on compressive strength of steel tube and concrete in square CFT columns.. Journal of Building Structures, 2019, 40(2): 161–168

[32]

Yu Q , Tao Z , Wu Y X . Experimental behaviour of high performance concrete-filled steel tubular columns. Thin-Walled Structures, 2008, 46(4): 362–370

[33]

Lv X L , Yu Y , Chen Y Y , Kiyoshi T , Satoshi S. . Studies on the behavior of concrete-filled rectangular tubular short column: I experiment.. Building Structure, 1999, 29(10): 41–43

[34]

Zhang S M , Guo L H , Ye Z L , Wang Y Y . Behavior of steel tube and confined high strength concrete for concrete-filled RHS tubes. Advances in Structural Engineering, 2005, 8(2): 101–116

[35]

Uy B . Strength of short concrete filled high strength steel box columns. Journal of Constructional Steel Research, 2001, 57(2): 113–134

[36]

Liu D L , Gho W M . Axial load behaviour of high-strength rectangular concrete-filled steel tubular stub columns. Thin-Walled Structures, 2005, 43(8): 1131–1142

[37]

Li D. Study on the Mechanical Properties of Concrete Filled High Strength Cold-formed Steel Tubular Columns. Thesis for the Master’s Degree. Jingzhou: Yangtze University, 2017 (in Chinese)

[38]

Huang C S , Yeh Y K , Liu G Y , Hu H T , Tsai K C , Weng Y T , Wang S H , Wu M H . Axial load behavior of stiffened concrete-filled steel columns. Journal of Structural Engineering, 2002, 128(9): 1222–1230

[39]

Wang Q P. An Experimental Study of Mechanical Behavior of Concrete-Filled Thin-Walled Steel Short Columns. Thesis for the Master’s Degree. Harbin: Harbin Institute of Technology, 2002 (in Chinese)

[40]

Tao Z, Yu Q. New Types of Composite Columns: Experiments, Theory and Methodology. Beijing: Science Press, 2006, 20–25 (in Chinese)

[41]

Rao Y L , Zhang J C , Li Y , Huang Y S , Li D. . Experiment on mechanical behavior of concrete-filled high-strength cold-formed steel tube short column under axial load.. Journal of Huaqiao University (Natural Science), 2019, 40(3): 338–343

[42]

Huang H , Chen M C , Wan C Y. . Behavior of concrete-filled stiffened square steel tubes subjected to eccentric compressive load.. China Civil Engineering Journal, 2011, 44(10): 26–34

[43]

Nguyen T T , Thai H T , Ngo T , Uy B , Li D X . Behaviour and design of high strength CFST columns with slender sections. Journal of Constructional Steel Research, 2021, 182: 106645

[44]

Han L H , Yao G H . Influence of concrete compaction on the strength of concrete-filled steel RHS columns. Journal of Constructional Steel Research, 2003, 59(6): 751–767

[45]

Liu D L , Gho W M , Yuan J . Ultimate capacity of high-strength rectangular concrete-filled steel hollow section stub columns. Journal of Constructional Steel Research, 2003, 59(12): 1499–1515

[46]

EN 1994-1-1:2004. Eurocode 4: Design of Composite Steel and Concrete Structures—Part 1-1: General Rules and Rules for Buildings. Brussels: European Committee for Standardization, 2004

[47]

Mander J B , Priestley M J N , Park R . Theoretical stress–strain model for confined concrete. Journal of Structural Engineering, 1988, 114(8): 1804–1826

[48]

Sakino K , Nakahara H , Morino S , Nishiyama I . Behavior of centrally loaded concrete-filled steel-tube short columns. Journal of Structural Engineering, 2004, 130(2): 180–188

[49]

Guo Z H, Shi X D. Reinforced Concrete Theory and Analyse. Beijing: Tsinghua University Press, 2003 (in Chinese)

[50]

ANSI/AISC 360-16. Specification for Structural Steel Buildings. Chicago, Illinois: American Institute of Steel Construction, 2016

Rights & permissions

Higher Education Press

PDF (23419KB)

Supplementary files

Supplementary materials

0

Accesses

0

Citation

Detail

Sections
Recommended

/

〈 〉