Predicting the capacity of perfobond rib shear connector using an ANN model and GSA method

Guorui SUN, Jun SHI, Yuang DENG

PDF(10179 KB)
PDF(10179 KB)
Front. Struct. Civ. Eng. ›› 2022, Vol. 16 ›› Issue (10) : 1233-1248. DOI: 10.1007/s11709-022-0878-1
RESEARCH ARTICLE
RESEARCH ARTICLE

Predicting the capacity of perfobond rib shear connector using an ANN model and GSA method

Author information +
History +

Abstract

Due to recent advances in the field of artificial neural networks (ANN) and the global sensitivity analysis (GSA) method, the application of these techniques in structural analysis has become feasible. A connector is an important part of a composite beam, and its shear strength can have a significant impact on structural design. In this paper, the shear performance of perfobond rib shear connectors (PRSCs) is predicted based on the back propagation (BP) ANN model, the Genetic Algorithm (GA) method and GSA method. A database was created using push-out test test and related references, where the input variables were based on different empirical formulas and the output variables were the corresponding shear strengths. The results predicted by the ANN models and empirical equations were compared, and the factors affecting shear strength were examined by the GSA method. The results show that the use of ANN model optimization by GA method has fewer errors compared to the empirical equations. Furthermore, penetrating reinforcement has the greatest sensitivity to shear performance, while the bonding force between steel plate and concrete has the least sensitivity to shear strength.

Graphical abstract

Keywords

perfobond rib shear connector / shear strength / ANN model / global sensitivity analysis

Cite this article

Download citation ▾
Guorui SUN, Jun SHI, Yuang DENG. Predicting the capacity of perfobond rib shear connector using an ANN model and GSA method. Front. Struct. Civ. Eng., 2022, 16(10): 1233‒1248 https://doi.org/10.1007/s11709-022-0878-1

References

[1]
Vigneri V, Odenbreit C, Romero A. Numerical study on design rules for minimum degree of shear connection in propped steel-concrete composite beams. Engineering Structures, 2021, 241(4): 112466
CrossRef Google scholar
[2]
Wu F, Liu S, Xue C, Yang K, Feng Y, Zhang H. Experimental study on the mechanical properties of perfobond rib shear connectors with steel fiber high strength concrete. Materials (Basel), 2021, 14(12): 3345
CrossRef Google scholar
[3]
Li Z, Zhao C, Deng K, Wang W. Load sharing and slip distribution in multiple holes of a perfobond rib shear connector. Journal of Structural Engineering, 2018, 144(9): 264–276
CrossRef Google scholar
[4]
Kim K, Han O, Heo W, Kim S. Behavior of Y-type perfobond rib shear connection under different cyclic loading conditions. Structures, 2020, 26: 562–571
CrossRef Google scholar
[5]
Gu J, Liu D, Deng W, Zhang J. Experimental study on the shear resistance of a comb-type perfobond rib shear connector. Journal of Constructional Steel Research, 2019, 158: 279–289
CrossRef Google scholar
[6]
Ahn J, Lee C, Won J, Kim S. Shear resistance of the perfobond-rib shear connector depending on concrete strength and rib arrangement. Journal of Constructional Steel Research, 2010, 66(10): 1295–1307
CrossRef Google scholar
[7]
Wang X, Zhu B, Cui S, Lui E. Experimental research on PBL connectors considering the effects of concrete stress state and other connection parameters. Journal of Bridge Engineering, 2018, 23(1): 04017125
CrossRef Google scholar
[8]
Costa-Neves L, Figueiredo J, Vellasco P, Vianna J. Perforated shear connectors on composite girders under monotonic loading: An experimental approach. Engineering Structures, 2013, 56: 721–737
CrossRef Google scholar
[9]
Cândido-Martins J, Costa-Neves L, Vellasco P. Experimental evaluation of the structural response of Perfobond shear connectors. Engineering Structures, 2010, 32(8): 1976–1985
CrossRef Google scholar
[10]
Zheng S, Zhao C, Liu Y. Analytical model for load-slip relationship of perfobond shear connector based on push-out test. Materials (Basel), 2018, 12(1): 1–19
CrossRef Google scholar
[11]
Leonhardt F, Andrae W, Andrae H, Harre W. New, improved bonding means for composite load bearing structures with high fatigue strength. Beton, 1987, 82(12): 325–331
CrossRef Google scholar
[12]
Oguejiofor E, Hosain M. A parametric study of perfobond rib shear connectors. Canadian Journal of Civil Engineering, 1994, 21(4): 614–625
CrossRef Google scholar
[13]
Kim S, Kim K, Han O, Park J. Influence of transverse rebar on shear behavior of Y-type perfobond rib shear connection. Construction & Building Materials, 2018, 180: 254–264
CrossRef Google scholar
[14]
Manabe Y, Fujiyama C, Kisaku T, Shionaga R. Influence of coarse aggregates on the shear resistance of perfobond rib shear connector. Procedia Engineering, 2014, 95(95): 454–464
CrossRef Google scholar
[15]
Su Q, Yang G, Bradford M. Bearing capacity of perfobond rib shear connectors in composite girder bridges. Journal of Bridge Engineering, 2016, 21(4): 06015009
CrossRef Google scholar
[16]
Zheng S, Liu Y Q, Yoda T, Lin W. Parametric study on shear capacity of circular-hole and long-hole perfobond shear connector. Journal of Constructional Steel Research, 2016, 117: 64–80
CrossRef Google scholar
[17]
Zheng S, Zhao C, Liu Y. Experimental shear strength evaluation of perfobond shear connector with various hole shapes. Structural Engineering and Mechanics, 2018, 67(2): 131–142
CrossRef Google scholar
[18]
Garzón-Roca J, Marco C, Adam J. Compressive strength of masonry made of clay bricks and cement mortar: Estimation based on Neural Networks and Fuzzy Logic. Engineering Structures, 2013, 48: 21–27
CrossRef Google scholar
[19]
Tzuc O, Gamboa O, Rosel R, Poot M, Edelman H, Torres M J, Bassam A. Modeling of hygrothermal behavior for green facade’s concrete wall exposed to nordic climate using artificial intelligence and global sensitivity analysis. Journal of Building Engineering, 2021, 33: 101625
CrossRef Google scholar
[20]
Sadrossadat S, Cao Y, Zhang Q. Parametric modeling of microwave passive components using sensitivity-analysis-based adjoint neural-network technique. IEEE Transactions on Microwave Theory and Techniques, 2013, 61(5): 1733–1747
CrossRef Google scholar
[21]
Bernus A, Ottlé C, Raoult N. Variance based sensitivity analysis of FLake lake model for global land surface modeling. Journal of Geophysical Research. Atmospheres, 2021, 126(8): 1–19
CrossRef Google scholar
[22]
Zamanian S, Terranova B, Shafieezadeh A. Significant variables affecting the performance of concrete panels impacted by wind-borne projectiles: A global sensitivity analysis. International Journal of Impact Engineering, 2020, 144: 103650
CrossRef Google scholar
[23]
Guo H, Zhuang X, Rabczuk T. A deep collocation method for the bending analysis of Kirchhoff plate. Computers, Materials & Continua, 2019, 59(2): 433–456
CrossRef Google scholar
[24]
Anitescu C, Atroshchenko E, Alajlan N, Rabczuk T. Artificial neural network methods for the solution of second order boundary value problems. Computers, Materials & Continua, 2019, 59(1): 345–359
CrossRef Google scholar
[25]
Samaniego E, Anitescu C, Goswami S, Nguyen-Thanh V M, Guo H, Hamdia K, Zhuang X, Rabczuk T. An energy approach to the solution of partial differential equations in computational mechanics via machine learning: Concepts, implementation and applications. Computer Methods in Applied Mechanics and Engineering, 2020, 362: 112790
CrossRef Google scholar
[26]
Zhuang X, Guo H, Alajlan N, Zhu H, Rabczuk T. Deep autoencoder based energy method for the bending, vibration, and buckling analysis of Kirchhoff plates with transfer learning. European Journal of Mechanics. A, Solids, 2021, 87: 104225
CrossRef Google scholar
[27]
Guo H, Zhuang X, Chen P, Alajlan N, Rabczuk T. Stochastic deep collocation method based on neural architecture search and transfer learning for heterogeneous porous media. Engineering with Computers, 2022, 1–26
CrossRef Google scholar
[28]
Guo H, Zhuang X, Chen P, Alajlan N, Rabczuk T. Analysis of three-dimensional potential problems in non-homogeneous media with physics-informed deep collocation method using material transfer learning and sensitivity analysis. Engineering with Computers, 2022, 1–22
CrossRef Google scholar
[29]
Safa M, Shariati M, Ibrahim Z, Toghroli A, Nor N M, Petkovic D. Potential of adaptive neuro fuzzy inference system for evaluating the factors affecting steel-concrete composite beam’s shear strength. Steel and Composite Structures, 2016, 21(3): 679–688
CrossRef Google scholar
[30]
Chahnasir E S, Zandi Y, Shariati M, Dehghani E, Toghroli A, Mohamed E T, Shariati A, Safa M, Wakil K, Khorami M. Application of support vector machine with firefly algorithm for investigation of the factors affecting the shear strength of angle shear connectors. Smart Structures and Systems, 2018, 22(4): 413–424
CrossRef Google scholar
[31]
Hamdia K M, Zhuang X, Rabczuk T. An efficient optimization approach for designing machine learning models based on genetic algorithm. Neural Computing & Applications, 2021, 33(6): 1923–1933
CrossRef Google scholar
[32]
Sedghi Y, Zandi Y, Shariati M, Ahmadi E, Azar V M, Toghroli A, Safa M, Mohamad E T, Khorami M, Wakil K. Application of ANFIS technique on performance of C and L shaped angle shear connectors. Smart Structures and Systems, 2018, 22(3): 335–340
CrossRef Google scholar
[33]
Toghroli A, Mohammadhassani M, Suhatril M, Shariati M, Ibrahim Z. Prediction of shear capacity of channel shear connectors using the ANFIS model. Steel and Composite Structures, 2014, 17(5): 623–639
CrossRef Google scholar
[34]
Shariati M, Mafipour M, Mehrabi P, Bahadori A, Zandi Y, Salih M N A, Nguyen H, Dou J, Song X, Poi-Ngian S. Application of a hybrid artificial neural network-particle swarm optimization (ANN-PSO) model in behavior prediction of channel shear connectors embedded in normal and high-strength concrete. Applied Sciences (Basel, Switzerland), 2019, 9(24): 5534
CrossRef Google scholar
[35]
Allahyari H, Nikbin I, Rahimi S, Heidarpour A. A new approach to determine strength of Perfobond rib shear connector in steel-concrete composite structures by employing neural network. Engineering Structures, 2018, 157: 235–249
CrossRef Google scholar
[36]
Khalaf J A, Majeed A A, Aldlemy M S, Ali Z H, Al Zand A W, Adarsh S, Bouaissi A, Hameed M M, Yaseen Z M. Hybridized deep learning model for perfobond rib shear strength connector prediction. Complexity, 2021, 2021(8): 1–21
CrossRef Google scholar
[37]
Pianosi F, Beven K, Freer J, Hall J W, Rougier J, Stephenson D B, Wagener T. Sensitivity analysis of environmental models: A systematic review with practical workflow. Environmental Modelling & Software, 2016, 79: 214–232
CrossRef Google scholar
[38]
Sobol I. Sensitivity estimates for nonlinear mathematical models. Mathematical Modeling & Computational Experiment, 1993, 1(4): 407–414
[39]
Homma T, Saltelli A. Importance measures in global sensitivity analysis of nonlinear models. Reliability Engineering & System Safety, 1996, 52(1): 1–17
CrossRef Google scholar
[40]
Zamanian S, Terranova B, Shafieezadeh A. Significant variables affecting the performance of concrete panels impacted by wind-borne projectiles: A global sensitivity analysis. International Journal of Impact Engineering, 2020, 144: 103650
CrossRef Google scholar
[41]
EN1994-1-1. Eurocode4: Design of Composite Steel and Concrete Structures. Brussels: European Committee for Standardization, 2004
[42]
DB41/T 696-2011. Technical Standard for Construction of Highway Waveform Steel Web Prestressed Concrete Box Girder Bridge Bracing Method. Henan: Henan Provincial Bureau of Quality and Technical Supervision, 2011
[43]
Ahn J, Kim S, Jeong Y. Shear behaviour of perfobond rib shear connector under static and cyclic loadings. Magazine of Concrete Research, 2008, 60(5): 347–357
CrossRef Google scholar
[44]
Medberry S, Shahrooz B. Perfobond shear connector for composite construction. Engineering Journal (New York), 2002, 39: 2–12
[45]
Yang Y, Chen Y. Experimental study on mechanical behavior of PBL shear connectors. Journal of Bridge Engineering, 2018, 23(9): 04018062
CrossRef Google scholar
[46]
VeríssimoGPaesJValenteICruzPFakuryR. Design and experimental analysis of a new shear connector for steel and concrete composite structures. In: 3rd International Conference on Bridge Maintenance, Safety and Management. Porto: IABMAS, 2006
[47]
Guan C, Duan Y, Zhai J, Han D. Hydraulic dynamics in split fuel injection on a common rail system and their artificial neural network prediction. Fuel, 2019, 255: 115792
CrossRef Google scholar

RIGHTS & PERMISSIONS

2022 Higher Education Press
AI Summary AI Mindmap
PDF(10179 KB)

Accesses

Citations

Detail

Sections
Recommended

/