A heat transfer experiment was conducted in a tube of 6.07mm in diameter with water flowing upward, covering the ranges of pressure of 10―23MPa, mass flux of 288―1298kg/(m2·s), local water temperature of 78°C―270°C, heat flux of 0.23―1.18MW/m2 and Reynolds number of 5.5×103―3.9×104. The experimental results were compared with the predictions of the Dittus-Boelter correlation, Jackson correlation, Bishop correlation, Swenson correlation and Yamagata correlation. Significant deterioration in heat transfer was observed in both subcritical and supercritical region due to the effect of buoyancy force, but it was not predicted reasonably by the existing correlations.
Yuzhou CHEN, Chunsheng YANG, Shuming ZHANG, Minfu ZHAO, Kaiwen DU,
. Heat transfer with water flowing upward in a
tube for pressures up to supercritical region[J]. Frontiers in Energy, 2010
, 4(3)
: 358
-365
.
DOI: 10.1007/s11708-009-0071-4