To improve the fault redundancy capability for the high reliability requirement of a brushless doubly-fed generation system applied to large offshore wind farms, the control winding of a brushless doubly-fed reluctance generator is designed as an open-winding structure. Consequently, the two ends of the control winding are connected via dual three-phase converters for the emerging open-winding structure. Therefore, a novel fault-tolerant control strategy based on the direct power control scheme is brought to focus in this paper. Based on the direct power control (DPC) strategy, the post-fault voltage vector selection method is explained in detail according to the fault types of the dual converters. The fault-tolerant control strategy proposed enables the open-winding brushless doubly-fed reluctance generator (BDFRG) system to operate normally in one, two, or three switches fault of the converter, simultaneously achieving power tracking control. The presented results verify the feasibility and validity of the scheme proposed.
Shi JIN , Long SHI , Sul ADEMI , Yue ZHANG , Fengge ZHANG . Fault-tolerant control of an open-winding brushless doubly-fed wind power generator system with dual three-level converter[J]. Frontiers in Energy, 2023 , 17(1) : 149 -164 . DOI: 10.1007/s11708-020-0711-2
1 |
Chaal H, Jovanovic M. Toward a generic torque and reactive power controller for doubly fed machines. IEEE Transactions on Power Electronics, 2012, 27(1): 113–121
|
2 |
Chaal H, Jovanovic M. Practical implementation of sensorless torque and reactive power control of doubly fed machines. IEEE Transactions on Industrial Electronics, 2012, 59(6): 2645–2653
|
3 |
Cheng M, Zhu Y. The state of the art of wind energy conversion systems and technologies: a review. Energy Conversion and Management, 2014, 88: 332–347
|
4 |
Attya A B, Ademi S, Jovanović M,
|
5 |
Zhang A, Wang X, Jia W,
|
6 |
Prasad R, Mulla M. A novel position-sensorless algorithm for field-oriented control of DFIG with reduced current sensors. IEEE Transactions on Sustainable Energy, 2019, 10(3): 1098–1108
|
7 |
Cheng M, Han P, Buja G,
|
8 |
Choi U, Lee J, Blaabjerg F,
|
9 |
Yang S, Bryant A, Mawby P,
|
10 |
Lu B, Sharma S. A literature review of IGBT fault diagnostic and protection methods for power inverters. IEEE Transactions on Industry Applications, 2009, 45(5): 1770–1777
|
11 |
Kwak S. Fault-tolerant structure and modulation strategies with fault detection method for matrix converters. IEEE Transactions on Power Electronics, 2010, 25(5): 1201–1210
|
12 |
Hoang K D, Zhu Z Q. Comparative performance study of alternate fault-tolerant inverter configurations for direct torque control-based three phase PM BLAC drives under single-phase open-circuit fault. In: 8th IET International Conference on Power Electronics, Machines and Drives (PEMD 2016), Glasgow, UK, 2016
|
13 |
Welchko B A, Lipo T A, Jahns T M,
|
14 |
Shahbazi M, Saadate S, Poure P,
|
15 |
Li X, Dusmez S, Akin B,
|
16 |
Restrepo J, Berzoy A, Ginart A,
|
17 |
Wang Z, Chen J, Cheng M,
|
18 |
Chowdhury S, Wheeler P, Patel C,
|
19 |
An Q, Liu J, Peng Z,
|
20 |
Jin S, Shi L, Zhu L,
|
21 |
Chaal H, Jovanovic M. Power control of brushless doubly-fed reluctance drive and generator systems. Renewable Energy, 2012, 37(1): 419–425
|
22 |
Zhao W, Wu B, Zhu Q. Fault-tolerant direct thrust force control for a dual inverter fed open-end winding linear vernier permanent-magnet motor using improved SVPWM. IEEE Transactions on Industrial Electronics, 2018, 65(9): 7458–7467
|
/
〈 | 〉 |