Addressing the volatile organic chemical spills in source water by air stripping: Model development and application

Tanyu Li , Wei Zhang , Ni Zhou , Yuxuan Xie , Xiaojin Zhang , Pengfei Lin , Jun Wang , Xiaojian Zhang , Chao Chen

ENG. Environ. ›› 2027, Vol. 21 ›› Issue (3) : 37

PDF (6149KB)
ENG. Environ. ›› 2027, Vol. 21 ›› Issue (3) :37 DOI: 10.1007/s11783-027-2337-7
RESEARCH ARTICLE
Addressing the volatile organic chemical spills in source water by air stripping: Model development and application
Author information +
History +
PDF (6149KB)

Abstract

The spills of volatile organic compounds (VOCs) occur frequently in source water and threaten the drinking water safety greatly, especially in rapidly industrializing countries. The VOC contaminants in water can be cost-effectively removed by air stripping. Aeration stripping can be more quickly applied in the field under emergency situation than packed-tower stripping. However, few studies have been conducted to establish a model for aeration stripping process. In this study, a model for VOC removal by aeration stripping was built on basis of the Henry’s Law and then verified by batch tests of eight VOCs including four halogenated hydrocarbons, two alkenyl halides and two benzene chemicals. Another model was established to describe the VOC removal by aeration stripping in continuous operation and verified by continuous flow tests with chloroform as representative contaminant. With these quantitative models, the air-water ratio required for a certain removal proportion can be determined according to the chemical’s basic properties, especially the constant of Henry’s Law. These models are very helpful to guide the emergency response on addressing the VOC spills in water source.

Graphical abstract

Keywords

Air stripping / Aeration stripping / Volatile organic chemical / Chemical spill / Emergency response

Highlight

● A model for VOC removal in water by air stripping was developed based on Henry’s Law.

● Air stripping zone can be divided into the mass transfer zone & the equilibrium zone.

● Air-water ratio for a certain removal is reciprocal to the Henry’s Law constant H.

● Batch & continuous experiments with 8 VOCs were conducted to validate the model.

● Difference between G by the model & the theoretical value is < 10% in equilibrium zone.

Cite this article

Download citation ▾
Tanyu Li, Wei Zhang, Ni Zhou, Yuxuan Xie, Xiaojin Zhang, Pengfei Lin, Jun Wang, Xiaojian Zhang, Chao Chen. Addressing the volatile organic chemical spills in source water by air stripping: Model development and application. ENG. Environ., 2027, 21 (3) : 37 DOI:10.1007/s11783-027-2337-7

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

Abdullahi M E , Abu Hassan M A , Noor Z Z , Ibrahim R K R . (2015). Temperature and air-water ratio influence on the air stripping of benzene, toluene and xylene. Desalination and Water Treatment, 54(10): 2832–2839

[2]

Anand S S , Philip B K , Mehendale H M . (2014). Volatile organic compounds. Encyclopedia of Toxicology, 3: 967–970

[3]

APHA (2017). Standard methods for the examination of water and wastewater, method 6232: trihalomethanes and chlorinated organic solvents. Washington, DC: American Public Health Association

[4]

ASCE (1988). Aeration: A Wastewater Treatment Process. New York: American Society of Civil Engineers

[5]

Ball B R , Edwards M D . (1992). Air stripping VOCs from groundwater: process design considerations. Environmental Progress, 11(1): 39–48

[6]

Clark R M , Adams J Q . (1991). Evaluation of BAT for VOCs in drinking water. Journal of Environmental Engineering, 117(2): 247–268

[7]

Ghoreyshi A A , Sadeghifar H , Entezarion F . (2014). Efficiency assessment of air stripping packed towers for removal of VOCs (volatile organic compounds) from industrial and drinking waters. Energy, 73: 838–843

[8]

Glória R M , Motta T M , Silva P V O , da Costa P , Brandt E M F , Souza C L , Chernicharo C A L . (2016). Stripping and dissipation techniques for the removal of dissolved gases from anaerobic effluents. Brazilian Journal of Chemical Engineering, 33(4): 713–721

[9]

Hou J , Gai W M , Cheng W Y , Deng Y F . (2021). Hazardous chemical leakage accidents and emergency evacuation response from 2009 to 2018 in China: a review. Safety Science, 135: 105101

[10]

Howard P H, Meylan W M (1997). Handbook of Physical Properties of Organic Chemicals. Boca Raton: Lewis Publishers

[11]

Huang J C, Shang C (2006). Air stripping. In: Wang L K, Hung Y T, Shammas N K, eds. Advanced Physicochemical Treatment Processes. Totowa: Humana Press, 47–79

[12]

Jin X, Wu Y J, Santhamoorthy M, Le T T N, Le V T, Yuan Y, Xia C L (2022). Volatile organic compounds in water matrices: recent progress, challenges, and perspective. Chemosphere, 308(Pt 1): 136182

[13]

Lin M Y , Yin X T , Cui F Y , Zhao Z W , Jiang Q . (2011). Removal of VOCs from sudden polluted raw water by air stripping. Journal of Donghua University, 28(5): 456–459

[14]

Liu B H , Li Y H , Ma J F , Huang L X , Chen L . (2016). Detection of semi-volatile organic compounds (SVOCs) in surface water, soil, and groundwater in a chemical industrial park in Eastern China. Water Science & Technology, 73(5): 1175–1189

[15]

Liu K Z , Yu Q , Yuan Z T , Yang Z S , Shu Y Q . (2021). A systematic analysis for maritime accidents causation in Chinese coastal waters using machine learning approaches. Ocean & Coastal Management, 213: 105859

[16]

Loo S L , Fane A G , Krantz W B , Lim T T . (2012). Emergency water supply: a review of potential technologies and selection criteria. Water Research, 46(10): 3125–3151

[17]

Ministry of Ecology and Environment of PRC (2016). Report on the state of the environment in China (1989–2016). Beijing: Ministry of Ecology and Environment of China

[18]

National Health Commission of PRC (2022). Standards for drinking water quality: GB 5749-2022. Standards Press of China. Beijing: National Health Commission of China

[19]

Qu J H , Meng X L , Ye X Q , You H . (2016). Characteristic variation and original analysis of emergent water source pollution accidents in China between 1985 and 2013. Environmental Science and Pollution Research, 23(19): 19675–19685

[20]

Rogers K, Britten M, Hartlaub M, von Bucher P (2011). Packed tower air stripping: an economical alternative for meeting California’s stringent THM limits. Annual Water Environment Federation Technical Exhibition and Conference, 1869–1889

[21]

Sander R . (2023). Compilation of Henry’s Law constants (version 5.0.0) for water as solvent. Atmospheric Chemistry and Physics, 23(19): 10901–12440

[22]

Staudinger J , Roberts P V . (2001). A critical compilation of Henry’s Law constant temperature dependence relations for organic compounds in dilute aqueous solutions. Chemosphere, 44(4): 561–576

[23]

Sun H , Hu X , Zhao D N , Xie H Y , Zhang X J , Chen C , Lin P F . (2023). Status quo and main influencing factors of environmental emergencies in China. Environmental Protection Science, 49(3): 130–138

[24]

U.S. EPA (2026). Toxic Pollutant List. Washington, DC: U.S. Environmental Protection Agency

[25]

Verma M K , Tyagi R K . (2012). Aeration of volatile organic compounds using gas dispersion impellers. Journal of Mechanical Engineering Research, 4(7): 213–224

[26]

Wang B L , Wan Y , Zheng G M , Hu J Y . (2016). Evaluating a tap water contamination incident attributed to oil contamination by nontargeted screening strategies. Environmental Science & Technology, 50(6): 2956–2963

[27]

Wu F T, Wu S J (2009). Removal of trihalomethanes from drinking water by air stripping. In: 2009 International Conference on Energy and Environment Technology. Guilin: IEEE, 695–698

[28]

Yang D D , Zheng Y , Peng K , Pan L D , Zheng J , Xie B J , Wang B H . (2022). Characteristics and statistical analysis of large and above hazardous chemical accidents in China from 2000 to 2020. International Journal of Environmental Research and Public Health, 19(23): 15603

[29]

Zhang K F , Chang S , Fu Q , Sun X B , Fan Y T , Zhang M L , Tu X , Qadeer A . (2021). Occurrence and risk assessment of volatile organic compounds in multiple drinking water sources in the Yangtze River Delta region, China. Ecotoxicology and Environmental Safety, 225: 112741

[30]

Zhang K F , Chang S , Wang E R , Zhang Q , Fan Y T , Bai Y S , Zhang M L , Fu Q , Jia W C . (2022). Occurrence, health risk, and removal efficiency assessment of volatile organic compounds in drinking water treatment plants (DWTPs): an investigation of seven major river basins across China. Journal of Cleaner Production, 372: 133762

[31]

Zhang W (2011). Study on air stripping as an emergency treatment technology for removing volatile organic compounds in source water. Master Degree Thesis. Tsinghua University, Beijing, China

[32]

Zhang X J , Chen C , Lin P F , Hou A X , Niu Z B , Wang J . (2011). Emergency drinking water treatment during source water pollution accidents in China: origin analysis, framework and technologies. Environmental Science & Technology, 45(1): 161–167

[33]

Zhou X H , Zhou X , Wang C M , Zhou H D . (2023). Environmental and human health impacts of volatile organic compounds: a perspective review. Chemosphere, 313: 137489

Rights & permissions

Higher Education Press 2027

PDF (6149KB)

Supplementary files

Supplementary materials

0

Accesses

0

Citation

Detail

Sections
Recommended

/

〈 〉