A highly sensitive and precise method for the determination of the polyamines (including putrescine, spermidine and spermine) in cell culture media is described. The samples were concentrated by C18 column and the polyamines were converted to fluorometric derivatives with DNS-Cl. The polyamine derivatives were then completely separated by HPLC and determined by simultaneous fluorometric detection. The CV of intragroup and intergroup were 2.49% – 4.26% and 4.29% – 5.16%, respectively. The rate of recovery was 103% – 99%. There was trace amount of polyamines detected by this method in the media of F12. 8900, RPMI-1640, DMEM and M199 even without incubation with cells. So this method can be used for detecting the changes of polyamines in a medium before and after incubation with cells. It is helpful for the researches on the regulation of cell proliferation by polyamines.

Keywords

medium / putrescine / spermidine / spermine / high performance liquid chromatography, fluorospectrophotometry

Cite this article

Download citation ▾
Wang Chun-ben, Lei Jing-mai, Chai Xi-lu, He Shan-shu. High performance liquid chromatography separation and simultaneous fluorometric detection of trace amount of polyamines in cell culture media. Current Medical Science, 1995, 15(2): 125-128 DOI:10.1007/BF02887917

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

Wang J Y, Johnson L R. Lumina polyamines stimulate repair of gastric mucosal stress ulcers. Am J Physiol, 1990; 259; NO. 4 G584

[2]

ElsagedN M, EllingsonA S, TierneyD F, et al.. Effects of ozone inhalation on polyamine metabolism and tritiated thymidine incorporation into DNA of rat lungs. Toxicol Appl Pharmacol, 1990, 102(1): 1-1

[3]

AtkinsonJ E, OlsonJ W, AltiereR J, et al.. Evidence that hypoxic pulmonary vascular remodeling in rats is polyamine dependent. J Appl Physiol, 1987, 62: 1562-1562

[4]

BrossatB, StraczekJ, BellevilleF, et al.. Determinaton of free and total polyamines in human serum and urine by ion-pairing high performance liquid chromatography using a radial compression module. J Chromatogr, 1983, 277: 87-87

[5]

KabraP M, LeeH K. Solid phase extraction and determination of dansyl derivatives of unconjugated and acetylated polyamines by reversed-phase liquid chromatography: Improved separation systems for polyamines in cerebrospinal fluid, urine and tissue. J Chromatogr, 1986, 380: 19-19

[6]

1983; 11 (8): 582

[7]

DannerR M, ReddyT V, GuiontC W. A sensitive reversed-phase ion-pairing HPLC method for the determination of polyamines in rat liver. LC-GC, 1994, 12(3): 244-244