Quantitative analysis of the tomographic technetium-99m MIBI (99mTc-MIBI) myocardial bullseye display: Application to diagnosis of coronary artery disease

Gao Zai-rong , Zhang Yong-xue , Hu Jia , Xu Wen-dai

Current Medical Science ›› 1995, Vol. 15 ›› Issue (2) : 65 -67.

PDF
Current Medical Science ›› 1995, Vol. 15 ›› Issue (2) : 65 -67. DOI: 10.1007/BF02887903
Article

Quantitative analysis of the tomographic technetium-99m MIBI (99mTc-MIBI) myocardial bullseye display: Application to diagnosis of coronary artery disease

Author information +
History +
PDF

Abstract

In this study, the99mTc-MIBI myocardial bullseye display of 31 healthy persons and 34 patients with myocardial ischemia and 17 patients with myocardial infarction were analyzed quantitatively, and compared with the results of myocardial tomography analysis and qualitative bullseye analysis. The sensitivities of the three methods were 88.2%, 91.2% and 94.1% respectively (P>0.05), and the specificities were 93.5%, 83, 9% and 83.9% respectively (P<0.05). On the other hand, the quantitative analysis obviously outperformed the other two methods in the detection of ischemic segments of myocardhum near infarction zone (P<0.01). The quantitative analysis of99mTc-MLBI myocardial bullseye (quantitative bullseye) was an objective, specific and sensitive method for diagnosis of coronary artery disease.

Keywords

technetium-99m MIBI / myocardial imaging / SPECT / bullseye / quantitative analysis / coronary artery disease

Cite this article

Download citation ▾
Gao Zai-rong, Zhang Yong-xue, Hu Jia, Xu Wen-dai. Quantitative analysis of the tomographic technetium-99m MIBI (99mTc-MIBI) myocardial bullseye display: Application to diagnosis of coronary artery disease. Current Medical Science, 1995, 15(2): 65-67 DOI:10.1007/BF02887903

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

LappoJ A, MeerdinkD J. Comparison of the myocardial uptake of a Technetium-labeled isonitrile analogue and Thallium. Circ Res., 1989, 65: 632-632

[2]

KiatH, MaddahiJ., RoyL T, et al.. Comparison of Tc-99m methoxy isobutyl isonitrile and T1- 201 for evaluation of coronary artery disease by planar and tomographic method. Am Heart J, 1989, 117: 1-1

[3]

CuocoloA, MaureaS, PaceL, et al.. Resting Tc-99m methoxy-isobutylisonitrile cardiac imaging in chronic coronary artery disease: comparison with rest-redistribution T1-201 scintigraphy. Eur J Nucl Med, 1993, 20: 1186-1186

[4]

RigoP, LarockM P, CantineauR, et al.. Evaluation of the extent of coronary artery disease with Tc-99m MIBI, a new myocardial perfusion agent. J Nucl Med, 1987, 28: 655-655

[5]

1992; 8: 124

[6]

KarcherG, BertrandA, AmorM, et al.. Quantitative and qualitative comparison of201T1 and99mTc-isonitrile by SPECT in coronary artery disease. J Nucl Med, 1987, 28: 654-654