A study of calcium ion-selective PVC membrane electrode based on neutral carrier N,n,n’,n’-tetracyclo-3-oxapetanediamide

Ma Yi-long , Rao Xiao-hong , Zhong Shi-ming , Ren Shu , Yu Tian-xiang , Zhen Qiong

Current Medical Science ›› 1992, Vol. 12 ›› Issue (2) : 98 -102.

PDF
Current Medical Science ›› 1992, Vol. 12 ›› Issue (2) : 98 -102. DOI: 10.1007/BF02887789
Article

A study of calcium ion-selective PVC membrane electrode based on neutral carrier N,n,n’,n’-tetracyclo-3-oxapetanediamide

Author information +
History +
PDF

Abstract

A calcium ion-selective PVC membrane electrode based on neutral carrier n,n,n’,n’-tetracyclohexyl-3-oxapetanediamide, using di-(2-ethylhexyl) phthalate as the plasticizer and potassium tetrakis (4-chlorophenyl) borate as the additive is reported in this paper. The ion selective membrane consists of 1 wt % of the Ca2+ selective ligand, 65 wt % of the plasticizer, 1 wt % of the additive and 33 wt % of poly (vinyl chloride) powder. The electrode has the linear response range of 2.0 × 10™7 —10™1 mol/L with the Nernstian slope of 28 mV/decade at 25 °C and the detection limit of 2.0 × 10™8 mol/L. The response time of the calcium ion-selective electrode is 4s as the concentration of calcium ion is rapidly shifted from 10™5 to 10™4 mol/L. The potential stability and reproducibility are good. The free calcium in blood serum was determined by the calcium ion-selective electrode with satisfactory results.

Keywords

calcium ion-selective electrode / neutral carrier / PVC membrane / calcium determination in serum

Cite this article

Download citation ▾
Ma Yi-long, Rao Xiao-hong, Zhong Shi-ming, Ren Shu, Yu Tian-xiang, Zhen Qiong. A study of calcium ion-selective PVC membrane electrode based on neutral carrier N,n,n’,n’-tetracyclo-3-oxapetanediamide. Current Medical Science, 1992, 12(2): 98-102 DOI:10.1007/BF02887789

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

RossJW. Calcium-selective electrode based on a liquid ion exchanger. Science, 1967, 156: 1387-1387

[2]

GriffithsGH, et al.. An investigation of the optimum composition of poly (vinyl chloride) matrix membranes used for calcium-selective electrodes. Analyst, 1972, 97: 420-420

[3]

MoodyJG, et al.. A calcium-sensitive electrode based on a liquid ion exchanger in a poly (vinyl chloride) matrix. Analyst, 1970, 95: 910-910

[4]

RuzikaJ, et al.. Selectrode-The universal ion-selective electrode, Part VI. The calcium (I) selectrode employing a new ion exchanger in a nonporous membrane and a solid state reference system. Anal Chim Acta, 1973, 67: 155-155

[5]

JagnerD, et al.. The suitability of various calcium electrodes based on metal salts of di-(n-octylphenyl) phosphoric acid and some derivatives for the measurement of caclcium in sea water. Anal Chim Acta, 1975, 80: 9-9

[6]

AmmannD, et al.. Improved calcium ion-selective electrode based on a neutral carrier. Anal Lett, 1975, 8: 709-709

[7]

AmmannD, et al.. Intracellular neutral carrier-based Ca2+ microelectrode with subnanomolar detection limit. Pflügers Arch, 1987, 409: 223-223

[8]

Wan JH. The characteristics and applications of calcium-selective membrane electrode based on neutral carrier. The Fourth National Meeting on Chemical Sensors. Chengdu, October, 1986

[9]

MaYL, MoradM. The improvement of characteristics of neutral carrier calcium selective microelectrode and instantaneous determination of extracellular photo-released calcium. Journal of Transduction Technology, 1987, 2: 18-18

[10]

WuHL, YuRQ. The study of PVC membrane pH electrode. The optimum membrane composition of PVC membrane pH electrodes are selected by cross desigh approach. Chemical Sensors, 1986, 6: 39-39

AI Summary AI Mindmap
PDF

83

Accesses

0

Citation

Detail

Sections
Recommended

AI思维导图

/