The chelating-resin modified electrode and its application in the detection of copper in human samples

Qiao Wen-jian , Lin Zhi-hong , Wu Meng

Current Medical Science ›› 1992, Vol. 12 ›› Issue (2) : 80 -84.

PDF
Current Medical Science ›› 1992, Vol. 12 ›› Issue (2) : 80 -84. DOI: 10.1007/BF02887785
Article

The chelating-resin modified electrode and its application in the detection of copper in human samples

Author information +
History +
PDF

Abstract

A new kind of carbon paste electrodes modified by chelating resin was prepared for detection of trace amount of copper in human hair. As the ion exchange between chelating resin and cupric ions and the coordination reaction on the modified electrode take place at the same time, this method has high sensitivity and good selectivity. The detection limit is 6 X 10™9mol/L. The average percentage of recovered copper is 108 ±8.3% and the variant coefficient(CV)7.7%.

Keywords

copper / modified electrode / carbon paste electrode / chelating resin

Cite this article

Download citation ▾
Qiao Wen-jian, Lin Zhi-hong, Wu Meng. The chelating-resin modified electrode and its application in the detection of copper in human samples. Current Medical Science, 1992, 12(2): 80-84 DOI:10.1007/BF02887785

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

AnsonF.. Electrochemistry and electroanalysis(in chinese), 1983BeijingPeking University Publishing House7-7

[2]

ThomsenKN, KrygerL. Voltammetric determination of traces of niklel (I) with a medium exchange how system and a chemically modified carbon paste electrode containing dimethylglyoxime. Anal Chem, 1988, 60: 151-151

[3]

WangJ. Preconcentration and voltammetric measurement of mercury with a crown-ether modified carbon-paste electrode. Talanta, 1988, 35: 277-277

[4]

KalcherK, et al.. Voltammetric determination of trace amounts of gold and a-chemically modified carbon paste electrode. Anal Chim Acta, 1985, 177: 175-175

[5]

WangJ, et al.. Carbon taste electrodes modified with cation-exchange resin in differential pulse voltammetry. Anal Chim Acta, 1984, 158: 15-15

[6]

HernandezL, et al.. Determination of cadmium(I) with carbon paste electrode modified with an ion-exchange resin. Analyst, 1989, 114: 397-397

[7]

HernandezL, et al.. Determination of copper(I) with a carbon paste electrode modified with an ion-exchange resin. Analyst, 1988, 113: 41-41

[8]

DonSJ, et al.. Application of Chemically modified electrode to analytical chemistry. Anal Chem(in Chinese), 1988, 16(10): 951-951

[9]

MitchellJW, ZiefM. The control of the contamination in the trace element analysis, 19811th ed.ShanghaiShanghai Scientific Literature Publishing House125-126