1585 cases of retinal detachment surgery with homologous skin as buckling material

Zeng Shui-qing , Shui Ying-bo , Hu Chun-zhi , Wei Hou-ren

Current Medical Science ›› 1992, Vol. 12 ›› Issue (1)

PDF
Current Medical Science ›› 1992, Vol. 12 ›› Issue (1) DOI: 10.1007/BF02887760
Article

1585 cases of retinal detachment surgery with homologous skin as buckling material

Author information +
History +
PDF

Abstract

From January 1963 to December 1989, 1585 consecutive cases of retinal detachment were operated with homologous skin as buckling material, the rate of operative success being 91.6 %. Human skin is easy to obtain, sterilize and preserve, because of its appropriate thickness and firm but elastic consistency it satisfactorily meets the need to produce sufficient height and to maintain necessary duration of the scierai buckling, in addition to a high rate of reattachment, homologous skin implantation was well tolerated, very rarely rejected (0.06 %) and infected (0.25 %), and no late complications occurred. Therefore, the authors prefer using human skin as buckling agent rather than conventional synthetic material, e.g., silicon sponge etc.

Cite this article

Download citation ▾
Zeng Shui-qing, Shui Ying-bo, Hu Chun-zhi, Wei Hou-ren. 1585 cases of retinal detachment surgery with homologous skin as buckling material. Current Medical Science, 1992, 12(1): DOI:10.1007/BF02887760

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

WinterR, Khorram-SefatC. Mikrochirurgie der Amotio retinae mit biologischem Plombenmaterial. Klin Mbl Augenheilk, 1988, 193: 611-611

[2]

LaquaH. Pars-Plana-Vitrektomie. Klin Mbl Augenheilk, 1979, 175: 602-602

[3]

HeydenreichA. Klinische und experimentelle Erfahrungen mit der Kutisplombe bei der Operation der Netzhautablösung. Klin Mbl Augenheilk, 1961, 138: 53-53

[4]

RassoLE, RuizRS. Silikon sponge rejection. Arch Ophthalmol, 1971, 85: 647-647

[5]

LindseyFS, et al.. Removal of scieral buckling elements. Arch Ophthalmol, 1983, 101: 570-570

[6]

1987:5:14

[7]

(Tolfon) 1987;5:219

[8]

HahnYS, et al.. Infection after sponge implantation for scierai buckling. Am J Ophthalmol, 1979, 87: 180-180

[9]

ChignellAH, et al.. Absorption of subretinal fluid after nondraieage retinal detachment surgery. Arch Ophthalmol, 1978, 96: 635-635

[10]

Jean-LouisB, et al.. An ultrasonographic study ef choroidal indentation height after scierai buckling with lyophilized human tissues. Graefes Arch Clin Exp Ophthalmol, 1985, 222: 158-158

[11]

MartiR, et al.. New absorbable synthetic expiants for the treatment of retinal detachment. Retina, 1987, 7: 102-102

[12]

LincoffH, KreissigI. Results with a temporary ballon buckle for the repair of retinal detachment. Am J Opbthalmol, 1981, 92: 245-245

[13]

BinderS, et al.. Die adäquate Ablatiooperation. Klin Mbl Augenheilk, 1984, 185: 342-342