The catalytic stripping voltammetre of trace copper (II) at a chemically modified electrode on oxine containing carbon paste

Qiao Wen-jian , Dina Hong

Current Medical Science ›› 1993, Vol. 13 ›› Issue (14) : 190 -193.

PDF
Current Medical Science ›› 1993, Vol. 13 ›› Issue (14) : 190 -193. DOI: 10.1007/BF02886515
Article

The catalytic stripping voltammetre of trace copper (II) at a chemically modified electrode on oxine containing carbon paste

Author information +
History +
PDF

Abstract

An oxine modified electrode is prepared qn the basis of carbon paste. The process is rapid and simple. The catalytic stripping voltammetric characteristic of Cu (II) on the modified electrode was studied and the method has been applied to the determination of trace Cu (II), and there was good linear relationship between the concentration of Cu (II) and the peak height in the concentration range of 1.5 x 10−9−1.5 × 10−6 mol/L for Cu (II). We have detected the copper content of human hair and blood with satisfactory results. Moreover, the reaction mechanism of the modified electrode was discussed. It was found that the improvement of sensitivity and selection of the modified electrode was dependent of the complex adsorbing property of the electrode surface and the sensitive catalytic hydrogen wave produce.

Keywords

oxine / carbon paste / chemically modified electrode / copper hair / blood

Cite this article

Download citation ▾
Qiao Wen-jian, Dina Hong. The catalytic stripping voltammetre of trace copper (II) at a chemically modified electrode on oxine containing carbon paste. Current Medical Science, 1993, 13(14): 190-193 DOI:10.1007/BF02886515

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

Anson F,1988:7

[2]

1984: 156

[3]

Kedon F A, Wilkingson G. 1980: 250

AI Summary AI Mindmap
PDF

89

Accesses

0

Citation

Detail

Sections
Recommended

AI思维导图

/