Axial compression tests and numerical simulation of steel reinforced recycled concrete short columns confined by carbon fiber reinforced plastics strips

Hui MA , Fangda LIU , Yanan WU , Xin A , Yanli ZHAO

Front. Struct. Civ. Eng. ›› 2022, Vol. 16 ›› Issue (7) : 817 -842.

PDF (16537KB)
Front. Struct. Civ. Eng. ›› 2022, Vol. 16 ›› Issue (7) : 817 -842. DOI: 10.1007/s11709-022-0844-y
RESEARCH ARTICLE
RESEARCH ARTICLE

Axial compression tests and numerical simulation of steel reinforced recycled concrete short columns confined by carbon fiber reinforced plastics strips

Author information +
History +
PDF (16537KB)

Abstract

To research the axial compression behavior of steel reinforced recycled concrete (SRRC) short columns confined by carbon fiber reinforced plastics (CFRP) strips, nine scaled specimens of SRRC short columns were fabricated and tested under axial compression loading. Subsequently, the failure process and failure modes were observed, and load-displacement curves as well as the strain of various materials were analyzed. The effects on the substitution percentage of recycled coarse aggregate (RCA), width of CFRP strips, spacing of CFRP strips and strength of recycled aggregate concrete (RAC) on the axial compression properties of columns were also analyzed in the experimental investigation. Furthermore, the finite element model of columns which can consider the adverse influence of RCA and the constraint effect of CFRP strips was founded by ABAQUS software and the nonlinear parameter analysis of columns was also implemented in this study. The results show that the first to reach the yield state was the profile steel in the columns, then the longitudinal rebars and stirrups yielded successively, and finally RAC was crushed as well as the CFRP strips was also broken. The replacement rate of RCA has little effect on the columns, and with the substitution rate of RCA from 0 to 100%, the bearing capacity of columns decreased by only 4.8%. Increasing the CFRP strips width or decreasing the CFRP strips spacing could enhance the axial bearing capacity of columns, the maximum increase was 10.5% or 11.4%, and the ductility of columns was significantly enhanced. Obviously, CFRP strips are conducive to enhance the axial bearing capacity and deformation capacity of columns. On this basis, considering the restraint effect of CFRP strips and the adverse effects of RCA, the revised formulas for calculating the axial bearing capacity of SRRC short columns confined by CFRP strips were proposed.

Graphical abstract

Keywords

steel reinforced recycled concrete / CFRP strips / short columns / axial compression behavior / recycled aggregate concrete

Cite this article

Download citation ▾
Hui MA, Fangda LIU, Yanan WU, Xin A, Yanli ZHAO. Axial compression tests and numerical simulation of steel reinforced recycled concrete short columns confined by carbon fiber reinforced plastics strips. Front. Struct. Civ. Eng., 2022, 16(7): 817-842 DOI:10.1007/s11709-022-0844-y

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

Rafaela C, Rui V S, Jorge de B, Ravindra D. Use of recycled aggregates from construction and demolition waste in geotechnical applications: A literature review. Waste Management (New York, N.Y.), 2016, 49(3): 131–145

[2]

Tereza P, Vladimír K, Petr H. Environmental assessment of two use cycles of recycled aggregate concrete. Sustainability (Basel), 2019, 11(21): 6185

[3]

Zhang J H, Wu Z Y, Zhang Y D, Fang Q, Yu H F, Jiang C L. Mesoscopic characteristics and macroscopic mechanical properties of coral aggregates. Construction & Building Materials, 2021, 309(22): 125125

[4]

Liu C Q, Wei X D, Lu Z, Wu H D, Yang Y L, Chen L Y. Studies on passive flexible protection to resist landslides caused by the May 12, 2008, Wenchuan earthquake. Structural Design of Tall and Special Buildings, 2017, 26(11): e1372

[5]

Vito F, Carlos M, Mirian V L. Effect of recycled concrete aggregate (RCA) on mortar’s thermal conductivity susceptibility to variations of moisture content and ambient temperature. Journal of Building Engineering, 2021, 43(11): 103208

[6]

Sun C, Chen Q, Xiao J, Ge W. Study on aggregate interlock behavior of pre-cracked recycled aggregate concrete without stirrups. Journal of Building Engineering, 2021, 39(7): 102257

[7]

Silva R V, de Brito J, Dhir R K. Fresh-state performance of recycled aggregate concrete: A review. Construction & Building Materials, 2018, 178(7): 19–31

[8]

Zhang J H, Li C, Ding L, Li J. Performance evaluation of cement stabilized recycled mixture with recycled concrete aggregate and crushed brick. Construction & Building Materials, 2021, 296(8): 123596

[9]

Du Y B, Zhao Z Q, Xiao Q, Shi F T, Yang J M, Gao P W. Experimental study on the mechanical properties and compression size effect of recycled aggregate concrete. Materials (Basel), 2021, 14(9): 2323

[10]

Syed M S K, Muhammad J M, Wu Y F, Indubhushan P, Zhou Y W, Feng X. Influence of different treatment methods on the mechanical behavior of recycled aggregate concrete: A comparative study. Cement and Concrete Composites, 2019, 104(11): 103398

[11]

Sepani S, Gregory L, Olivia M, Vivian W Y T, Kang W H. Recycle concrete in structural Applications for sustainable construction Practices in Australia. Procedia Engineering, 2017, 180(4): 751–758

[12]

Dong H Y, Li Y N, Cao W L, Guo Y L. Seismic behavior of full-scale steel reinforced recycled concrete columns under high axial compression ratio. Structures, 2021, 29(2): 1882–1897

[13]

Ma H, Jia C J, Xi J C, Dong J, Zhang X C, Zhan Y L. Cyclic loading test and nonlinear analysis on composite frame consisting of steel reinforced recycled concrete columns and steel beams. Engineering Structures, 2021, 241(8): 112480

[14]

Huang W, Fan Z C, Shen P L, Lu L N, Zhou Z. Experimental and numerical study on the compressive behavior of micro-expansive ultra-high-performance concrete-filled steel tube columns. Construction & Building Materials, 2020, 254(9): 119150

[15]

Ma H, Xi J C, Zhao Y L, Dong J K. Mechanical behaviour of composite columns composed of RAC-filled square steel tube and profile steel under eccentric compression loads. Steel and Composite Structures, 2021, 38(1): 103–120

[16]

Dong J, Ma H, Liu Y H, Guo T T. Numerical analysis and axial bearing capacity of composite columns with recycled aggregate concrete-filled steel tube and profile steel. Arabian Journal for Science and Engineering, 2020, 45(1): 3581–3598

[17]

Ma H, Dong J, Hu G B, Liu Y H. Axial compression performance of composite short columns composed of RAC-filled square steel tube and profile steel. Journal of Constructional Steel Research, 2019, 153(2): 416–430

[18]

Ma H, Dong J, Liu Y H, Guo T T. Compressive behaviour of composite columns composed of RAC-filled circular steel tube and profile steel under axial loading. Journal of Constructional Steel Research, 2018, 143(4): 72–82

[19]

Zhao T F. Bearing capacity studies on square steel tube confined steel reinforced concrete column under eccentric load. Advances in Civil Engineering, 2020, 2020(5): 4212049

[20]

Vivian W Y, Xiao J, Liu S, Chen Z. Behaviors of recycled aggregate concrete-filled steel tubular columns under eccentric loadings. Frontiers of Structural and Civil Engineering, 2019, 13(3): 628–639

[21]

Cao Y G, Liu M Y, Wu Y F. Effect of low strain rate on the axial behavior of concrete in CFRP-confined circular cylinders. Construction & Building Materials, 2020, 255(9): 119351

[22]

Wang Y L, Cai G C, Amir S L, Danièle W, Konstantinos D T, Ran J H. Monotonic axial compressive behaviour and confinement mechanism of square CFRP-steel tube confined concrete. Engineering Structures, 2020, 217(8): 110802

[23]

Liu X, Wu T, Chen H X, Liu Y. Compressive stress-strain behavior of CFRP-confined lightweight aggregate concrete reinforced with hybrid fibers. Composite Structures, 2020, 244(7): 112288

[24]

Yasmin M, Wassel A B, Ahmed A. Seismic retrofitting of severely damaged RC connections made with recycled concrete using CFRP sheets. Frontiers of Structural and Civil Engineering, 2020, 14(2): 554–568

[25]

Chen G M, He Y H, Jiang T, Lin C J. Behavior of CFRP-confined recycled aggregate concrete under axial compression. Construction & Building Materials, 2016, 111(5): 85–97

[26]

GB/T-25177-2010. Recycled Coarse Aggregate for Concrete. Beijing: China Standards Press, 2010 (in Chinese)

[27]

CECS146:2003. Technical Specification for Concrete Structures Strengthened with Carbon Fiber Sheet. Beijing: China Planning Press, 2003 (in Chinese)

[28]

Ma H, Wu Y N, Huang C, Zhao Y L. Mechanical properties and bearing capacity of CFRP configured steel reinforced recycled concrete columns under axial compression loading. Structural Engineering and Mechanics, 2021, 79(4): 451–472

[29]

Xiao J Z. Experimental study on complete stress−strain curve of recycled concrete under uniaxial compression. Journal of Tongji University (Natural Science Edition), 2007, 52(11): 1445–1449

[30]

GB50010-2015. Code for Design of Concrete Structures. Beijing: China Construction Industry Press, 2015 (in Chinese)

[31]

XiaoJ ZLanY. Experimental study on uniaxial tensile properties of recycled concrete. Journal of Building Materials, 2006, 51(2):154–158 (in Chinese)

[32]

Hashin Z. Failure Criteria for unidirectional fiber composites. Journal of Applied Mechanics, 1980, 47(2): 329–334

[33]

RealfonzoRAaVV. ACI 440.2R-08. Guide for the Design and Construction of Externally Bonded FRP Systems for Strengthening Concrete Structures. Michigan: American Concrete Institute, 2008

[34]

XiaoJ ZYangJHuangY JWangZ P. Experimental study on axial pressure of recycled concrete with steel tube restraint. Journal of Architectural Structure, 2011, 32(6):92–98 (in Chinese)

[35]

Zeng J J, Guo Y C, Gao W Y, Li J Z, Xie J H. Behavior of partially and fully FRP-confined circularized square columns under axial compression. Construction & Building Materials, 2017, 152(10): 319–332

[36]

Zeng J J, Guo Y C, Gao W Y, Chen W P, Li L J. Stress−strain behavior of concrete in circular concrete columns partially wrapped with FRP strips. Composite Structures, 2018, 200(9): 810–828

[37]

Chrzanowski M, Odenbreit C, Obiala R, Bogdan T, Degée H. Effective bending stiffness of steel−concrete composite columns with multiple encased steel profiles. Journal of Constructional Steel Research, 2021, 181(6): 106607

[38]

Liang J F, Lin S Q, Li W, Liu D W. Axial compressive behavior of recycled aggregate concrete-filled square steel tube stub columns strengthened by CFRP. Structures, 2021, 29(2): 1874–1881

RIGHTS & PERMISSIONS