PDF
(1002KB)
Abstract
This study examines the properties of fiber-reinforced reactive powder concrete (FR-RPC). Steel fibers, glass fibers, and steel-glass hybrid fibers were used to prepare the FR-RPC. The non-fibrous reactive powder concrete (NF-RPC) was prepared as a reference mix. The proportion of fibers by volume for all FR-RPC mixes was 1.5%. Steel fibers of 13 mm length and 0.2 mm diameter were used to prepare the steel fiber-reinforced RPC (SFR-RPC). Glass fibers of 13 mm length and 1.3 mm diameter were used to prepare the glass fiber-reinforced RPC (GFR-RPC). The hybrid fiber-reinforced RPC (HFR-RPC) was prepared by mixing 0.9% steel fibers and 0.6% glass fibers. Compressive strength, axial load-axial deformation behavior, modulus of elasticity, indirect tensile strength, and shear strength of the RPC mixes were investigated. The results showed that SFR-RPC achieved higher compressive strength, indirect tensile strength and shear strength than NF-RPC, GFR-RPC, and HFR-RPC. Although the compressive strengths of GFR-RPC and HFR-RPC were slightly lower than the compressive strength of NF-RPC, the shear strengths of GFR-RPC and HFR-RPC were higher than that of NF-RPC.
Keywords
reactive powder concrete
/
steel fiber
/
glass fiber
/
hybrid fiber
Cite this article
Download citation ▾
Atheer H. M. ALGBURI, M. Neaz SHEIKH, Muhammad N. S. HADI.
Mechanical properties of steel, glass, and hybrid fiber reinforced reactive powder concrete.
Front. Struct. Civ. Eng., 2019, 13(4): 998-1006 DOI:10.1007/s11709-019-0533-7
| [1] |
Richard P, Cheyrezy M. Composition of reactive powder concretes. Cement and Concrete Research, 1995, 25(7): 1501–1511
|
| [2] |
Lee M G, Wang Y C, Chiu C T. A preliminary study of reactive powder concrete as a new repair material. Construction & Building Materials, 2007, 21(1): 182–189
|
| [3] |
Zhang Y, Sun W, Liu S, Jiao C, Lai J. Preparation of C200 green reactive powder concrete and its static-dynamic behaviors. Cement and Concrete Composites, 2008, 30(9): 831–838
|
| [4] |
Chang T, Chen B, Wang J, Wu C. Performance of Reactive Powder Concrete (RPC) with Different Curing Conditions and Its Retrofitting Effects on Concrete Member. London: Taylor & Francis Group, 2009, 1203–1208
|
| [5] |
Malik A R, Foster S J. Carbon fibre-reinforced polymer confined reactive powder concrete columns-experimental investigation. ACI Structural Journal, 2010, 107(3): 263–271
|
| [6] |
Lee N P, Chisholm D H. Reactive Powder Concrete. Study Report no. SR146, 2005, 1–29
|
| [7] |
Tam C M, Tam V W Y, Ng K M. Optimal conditions for producing reactive powder concrete. Magazine of Concrete Research, 2010, 62(10): 701–716
|
| [8] |
Hiremath P N, Yaragal S C. Effect of different curing regimes and durations on early strength development of reactive powder concrete. Construction & Building Materials, 2017, 154(1): 72–87
|
| [9] |
Al-Tikrite A, Hadi M N S. Mechanical properties of reactive powder concrete containing industrial and waste steel fibres at different ratios under compression. Construction & Building Materials, 2017, 154(1): 1024–1034
|
| [10] |
Liu C T, Huang J S. Fire performance of highly flowable reactive powder concrete. Construction & Building Materials, 2009, 23(5): 2072–2079
|
| [11] |
Ahmad S, Zubair A, Maslehuddin M. Effect of key mixture parameters on flow and mechanical properties of reactive powder concrete. Construction & Building Materials, 2015, 99(1): 73–81
|
| [12] |
Ju Y, Jia Y, Liu H, Chen J. Mesomechanism of steel fibre reinforcement and toughening of reactive powder concrete. Science in China Series E: Technological Sciences, 2007, 50(6): 815–832
|
| [13] |
Shaheen E, Shrive N. Optimization of mechanical properties and durability of reactive powder concrete. ACI Materials Journal, 2006, 103(6): 444–451
|
| [14] |
Sanchayan S, Foster S J. High temperature behaviour of hybrid steel-PVA fibre reinforced reactive powder concrete. Materials and Structures, 2015, 48(1): 1–15
|
| [15] |
Canbaz M. The effect of high temperature on reactive powder concrete. Construction & Building Materials, 2014, 70(1): 508–513
|
| [16] |
Ferreira J P J G, Branco F A B. The use of glass fibre reinforced concrete as a structural material. Experimental Techniques, 2007, 31(3): 64–73
|
| [17] |
Glass Reinforced Concrete Association. Specifiers Guide to Glass Reinforced Concrete. Northampton: Glass Reinforced Concrete Association, 2012, 1–4
|
| [18] |
Australian Standards 3972. General Purpose and Blended Cements. Sydney: Australian Standards, 2010
|
| [19] |
SIMCOA operations PTY. LTD. Micro Silica Material Safety Data Sheet. Australia, 2018
|
| [20] |
Australasian (iron & steel) Slag Association (ASA). Wollongong, NSW, Australia, 2018
|
| [21] |
Australia S. Sika Viscocrete PC HRF-2 High Range Water Reducer-Material Safety Data Sheet. Australia, 2018
|
| [22] |
Ganzhou Daye Metallic Fibres Co. Ltd. Micro Steel Fibre WSF0213 III Specifications. China, 2018
|
| [23] |
Nippon Electric Glass Co. Ltd., (NEG). High Integrity Chopped Strand Alkali Resistant Glass Fibre. Japan, 2018
|
| [24] |
ASTM C230/C230M-14. Standard Specification for Flow Table for use in Tests of Hydraulic Cement. American Society for Testing and Materials. West Conshohocken, PA, United States, 2014
|
| [25] |
Malik A R, Foster S J. Behaviour of reactive powder concrete columns without steel ties. Journal of Advanced Concrete Technology, 2008, 6(2): 377–386
|
| [26] |
AS 1012.9. Compressive Strength Tests—Concrete, Mortar And Grout Specimen. Sydney: Australian Standards, 2014
|
| [27] |
AS 1012.17. Methods of Testing Concrete: Determination of the Static Chord Modulus of Elasticity and Poisson’s Ratio of Concrete Specimens. Sydney: Australian Standards, 2014
|
| [28] |
AS 1012.10. Determination of Indirect Tensile Strength of Concrete Cylinders. Sydney: Australian Standards, 2014
|
| [29] |
JS SF6. Method of Test for Shear Strength of Steel Fibre Reinforced Concrete. Tokyo: Japan Society of Civil Engineers (JSCE), 1999
|
| [30] |
Anderson R, Dewar J. Manual of Ready-mixed Concrete. 3rd ed. London: CRC Press, 2003
|
| [31] |
Hadi M N. Behaviour of eccentric loading of FRP confined fibre steel reinforced concrete columns. Construction & Building Materials, 2009, 23(2): 1102–1108
|
| [32] |
Ou Y C, Tsai M S, Liu K Y, Chang K C. Compressive behavior of steel-fiber-reinforced concrete with a high reinforcing index. Journal of Materials in Civil Engineering, 2012, 24(2): 207–215
|
| [33] |
Mehta P K, Monteiro P J M. Concrete: Microstructure, Properties, and Materials. 4th ed. New York: McGraw-Hill Education, 2014
|
| [34] |
Maroliya M. Behavior of reactive powder concrete in direct shear. IOSR Journal of Engineering, 2012, 2(9): 76–79
|
| [35] |
Boulekbache B, Hamrat M, Chemrouk M, Amziane S. Influence of yield stress and compressive strength on direct shear behaviour of steel fibre-reinforced concrete. Construction & Building Materials, 2012, 27(1): 6–14
|
RIGHTS & PERMISSIONS
Higher Education Press and Springer-Verlag GmbH Germany, part of Springer Nature