Experimental analysis on strength and failure modes of wood beam-column connections

Zhenhua HUANG , Sheldon Q SHI , Liping CAI

Front. Struct. Civ. Eng. ›› 2014, Vol. 8 ›› Issue (3) : 260 -269.

PDF (4057KB)
Front. Struct. Civ. Eng. ›› 2014, Vol. 8 ›› Issue (3) : 260 -269. DOI: 10.1007/s11709-014-0261-y
RESEARCH ARTICLE
RESEARCH ARTICLE

Experimental analysis on strength and failure modes of wood beam-column connections

Author information +
History +
PDF (4057KB)

Abstract

This research experimentally examined the strength, failure modes, and behaviors of dowel-bearing and fiber-bearing wood beam-column connections and explored the effects of cyclic loading on the strength, failure modes, and behaviors of those connections. Base on limited numbers of exploratory laboratory tests (6 preliminary tests in total), the authors observed that the typical bolted connection (dowel-bearing type wood beam-column connection with fiber-bearing surfaces) showed good behavior (large peak moment) under the monotonic loads, and the tenon joint connection (fiber-bearing wood beam-column connection) showed good behavior under cyclic loads. The cyclic property of loading reduced the strength of the dowel-bearing type wood beam-column connections, but increased the strength of fiber-bearing type wood beam-column connections. More importantly, the authors identified a possible location of safety concern in current national design specifications (NDS) standards for the typical bolted connection (dowel-bearing connection with fiber bearing surface) under cyclic loading because the tested value was smaller than the NDS calculated value. But, because of the small amount of tests conducted, no final conclusion can be drawn based on those preliminary observations yet. A large number of repetitive laboratory tests should be conducted.

Keywords

wood / connection / dowel-bearing / fiber-bearing

Cite this article

Download citation ▾
Zhenhua HUANG, Sheldon Q SHI, Liping CAI. Experimental analysis on strength and failure modes of wood beam-column connections. Front. Struct. Civ. Eng., 2014, 8(3): 260-269 DOI:10.1007/s11709-014-0261-y

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

Li J. Ying Zao Fa Shi. Royal Press, Kaifeng, China (Song Dynasty), 1100 (in Chinese)

[2]

Ma B J. Construction Technology of Chinese Ancient Timber Architectures. 2nded. Beijing: Science Press, 2003 (in Chinese)

[3]

Song X, Lam F. Laterally braced wood beam-columns subjected to biaxial eccentric loading. Computers & Structures, 2009, 87(17–18): 1058–1066

[4]

Xing H, Xue S, Zong G. Dynamic properties of conventional beam-column timber structure under successive damage. Journal of Asian Architecture and Building Engineering, 2011, 202(1): 195–202

[5]

O’Loinsigh C, Oudjene M, Ait-Aider H, Fanning P, Pizzi A, Shotton E, Meghlat E M. Experimental study of timber-to-timber composite beam using welded-through wood dowels. Construction & Building Materials, 2012, 36: 245–250

[6]

Leijten A J M, Brandon D. Advances in moment transferring dvw reinforced timber connections- Analysis and experimental verification, Part 1. Construction & Building Materials, 2013, 43: 614–622

[7]

NDS. National Design Specification for Wood Construction ASD/LRFD. American Forest & Paper Association, Washington, DC, 2012

[8]

DCS. Deck Construction Specifications of the Building Department of the City of Lancaster, Lancaster, OH, 2004

[9]

ASTM E2126. Standard Test Methods for Cyclic (Reversed) Load Test for Shear Resistance of Walls for Buildings, American Society for Testing and Materials, West Conshohocken, PA, 2007

RIGHTS & PERMISSIONS

Higher Education Press and Springer-Verlag Berlin Heidelberg

AI Summary AI Mindmap