Modeling and control of a permanent magnet synchronous generator dedicated to standalone wind energy conversion system
Received date: 16 Sep 2015
Accepted date: 29 Dec 2015
Published date: 27 May 2016
Copyright
The interest for the use of renewable energies has increased, because of the increasing concerns of the environmental problems. Among renewable energies, wind energy is now widely used. Wind turbines based on an asynchronous generator with a wound rotor present the inconvenience of requiring a system of rings and brooms and a multiplier, inferring significant costs of maintenance. To limit these inconveniences, certain manufacturers developed wind turbines based on synchronous machines with large number of pairs of poles coupled directly with the turbine, avoiding using the multiplier. If the generator is equipped with permanent magnets, the system of rings and brooms is eliminated. The control of the permanent magnet synchronous generator (PMSG) can be affected with the implementation of various techniques of control. This paper presented a new approach mainly based on the control strategy of power production system based on the PMSG. In fact, a mathematical model that simulates the Matlab chain was established with the introduction of control techniques, such as direct control of the torque (DTC) to control the load side converter (LSC), the control of the speed of the turbine and the DC-bus voltage ensured by PI regulators. To show the performance of the correctors used, some simulation results of the system were presented and analyzed.
Louar FATEH , Ouari AHMED , Omeiri AMAR , Djellad ABDELHAK , Bouras LAKHDAR . Modeling and control of a permanent magnet synchronous generator dedicated to standalone wind energy conversion system[J]. Frontiers in Energy, 2016 , 10(2) : 155 -163 . DOI: 10.1007/s11708-016-0410-1
1 |
Kumar S, Kumaresan N, Gounden N A, Rakesh N. Analysis and control of wind-driven self-excited induction generators connected to the grid through power converters. Frontiers in Energy, 2012, 6(4): 403–412
|
2 |
Dash P K, Padhee M, Barik S K. Estimation of power quality indices in distributed generation systems during power is landing conditions. International Journal of Electrical Power & Energy Systems, 2012, 36(1): 18–30
|
3 |
Hansen L H, Madsen P H, Blaabjerg F, Christensen H C, Lindhard U, Eskildsen K. Generators and power electronics technology for wind turbines. In: Proceedings of the 27th Annual Conference of the IEEE Industrial Electronics Society. Denver, USA 2001, 2000–2005
|
4 |
Patil N S, Bhosle Y N. A review on wind turbine generator topologies. In: Proceedings of 2013 International Conference on Power, Energy & Control. Dindigul, India, 2013, 625–629
|
5 |
Alnasir Z, Kazerani M. An analytical literature review of stand-alone wind energy conversion systems from generator viewpoint. Renewable & Sustainable Energy Reviews, 2013, 28: 597–615
|
6 |
Jin M, Qiu J, Shi C, Lin R. A fuzzy DTC method with a SVM defuzzification to permanent magnet synchronous machine. In: Proceeding of the 30th Annual Conference of the IEEE Industrial Electronics Society. Busan, South Korea, 2004, 3196–3199
|
7 |
Mansour M, Rachdi S, Mansouri M N, Mimouni M F. Direct torque control strategy of an induction-machine-based Flywheel energy storage system associated to a variable-speed wind generator. Energy and Power Engineering, 2012, 4(04): 255–263
|
8 |
Li N, Yu B, Liu L, Kong B. Simulation study on permanent magnet wind power generation system based on PSIM. International Journal of Advanced Research in Electrical. Electronics and Instrumentation Engineering, 2014, 3(4): 8279–8286
|
9 |
Bekakra Y, Ben Attous D. DFIG sliding mode control fed by back-to-back PWM converter with DC-link voltage control for variable speed wind turbine. Frontiers in Energy, 2014, 8(3): 345–354
|
10 |
Hussein M M, Senjyu T, Orabi M, Wahab M, Hamada M. Control of a stand-alone variable speed wind energy supply system. Applied Sciences, 2013, 3(2): 437–456
|
11 |
Djoudi A. Robust a wind farm based on an asynchronous doubly fed. Review of Renewable Energy, 2012, 15(4): 629–637
|
12 |
Djellad A, Logerais P O, Omeiri A, Riou O, Durastanti J F, Khelfi A. Modeling of wind energy conversion system and power quality analysis. In : International Conference on Renewable Energy. Sousse, Tunisie, 2013
|
13 |
Messaoud M, Abdessamed R. Modeling and optimization of wind turbine driving permanent magnet synchronous generator. Jordan Journal of Mechanical and Industrial Engineering, 2011, 5(6): 489–494
|
14 |
Benchabane F, Titaouine A, Bennis O, Yahia K, Taibi D, Guettaf A. Sensorless direct torque control for salient-pole PMSM based on extended Kalman filter fed by AC/DC/AC converter. Frontiers in Energy, 2012, 6(3): 247–254
|
15 |
Messaoud M, Abdessamed R. Modeling and optimization of wind turbine driving permanent magnet synchronous generator. Jordan Journal of Mechanical and Industrial Engineering, 2011, 5(6): 489–494
|
16 |
Bouscayrol A, Delarue P, Guillaud X. Power strategies for maximum control structure of a wind energy conversion system with a synchronous machine. Renewable Energy, 2005, 30(15): 2273–2288
|
17 |
El Aimani S, Francois B, Robyns B. Modeling of variable speed wind generator connected to a common DC bus. International Forum on Renewable Energy, FIER 2002, T’etouan, Maroc, 8-10 mai 2002
|
18 |
Morlaye Sekou C A M A R A, Mamadou Baïlo C A M A R A, Brayima D A K Y O, Hamid G U A L O U S. Modeling and control of permanent magnet synchronuous generator for the production and injection of offshore energy in network. symposium of Electrical Engineering (Sge’14), Ef-Epf-Mge, 2014: 8–10 (Ens Cachan, France)
|
19 |
Tapia A, Tapia G, Ostolaza J, Saenz J R. Modeling and control of a wind turbine driven doubly fed induction generator. IEEE Transactions on Energy Conversion, 2003, 18(2): 194–204
|
20 |
Diallo M O F, Camara M B, Youssef S, Gualous H, Dakyo B. Energetic capability characterization of the Raz Blanchard area for the tidal turbine farm implementation. In: IEEE African Conference: Sustainable Engineering for a Better Future (AFRICON). Mauritius, 2013
|
21 |
Depenbrock M. Direct self-control (DSC) of inverter-fed induction machine. IEEE Transactions on Power Electronics, 1988, 3(4): 420–429
|
22 |
Takahashi I, Mochikawa H. A new control of PWM inverter waveform for minimum loss operation of an induction motor drive. IEEE Transactions on Industry Applications, 1985, IA-21(3): 580–587
|
23 |
Ray R N, Chatterjee D, Goswami S K. An application of PSO technique for harmonic elimination in a PWM inverter. Applied Soft Computing, 2009, 9(4): 1315–1320
|
24 |
Bouafia A, Gaubert J P, Krim F. Design and implementation of predictive current control of three phase PWM rectifier using space vector modulation (SVM). Energy Conversion and Management, 2010, 51(12): 2473–2481
|
25 |
Moulay-Idriss C, Mohamed B. Application of the DTC control in the photovoltaic pumping system. Energy Conversion and Management, 2013, 65: 655–662
|
/
〈 | 〉 |