Energy distribution between liquid hydrogen and liquid oxygen temperatures in a Stirling/pulse tube refrigerator

Kongkuai YING, Wang YIN, Yinong WU, Zhenhua JIANG, Jiantang SONG, Shaoshuai LIU, Haifeng ZHU

PDF(1264 KB)
PDF(1264 KB)
Front. Energy ›› 2023, Vol. 17 ›› Issue (4) : 516-526. DOI: 10.1007/s11708-022-0844-6
RESEARCH ARTICLE
RESEARCH ARTICLE

Energy distribution between liquid hydrogen and liquid oxygen temperatures in a Stirling/pulse tube refrigerator

Author information +
History +

Abstract

A two-stage gas-coupled Stirling/pulse tube refrigerator (SPR), whose first and second stages respectively involve Stirling and pulse tube refrigeration cycles, is a very promising spaceborne refrigerator. The SPR has many advantages, such as a compact structure, high reliability, and high performance, and is expected to become an essential refrigerator for space applications. In research regarding gas-coupled regenerative refrigerator, the energy flow distribution between the two stages, and optimal phase difference between the pressure wave and volume flow, are two critical parameters that could widely influence refrigerator performance. The effects of displacer displacement on the pressure wave, phase difference, acoustic power distribution, and inter-stage cooling capacity shift of the SPR have been investigated experimentally. Notably, to obtain the maximum first-stage cooling capacity, an inflection point in displacement exists. When the displacer displacement is larger than the inflection point, the cooling capacity could be distributed between the first and second stages. In the present study, an SPR was designed and manufactured to work between the liquid hydrogen and liquid oxygen temperatures, which can be used to cool small-scale zero boil-off systems and space detectors. Under appropriate displacer displacement, the SPR can reach a no-load cooling temperature of 15.4 K and obtain 2.6 W cooling capacity at 70 K plus 0.1 W cooling capacity at 20 K with 160 W compressor input electric power.

Graphical abstract

Keywords

Stirling/pulse tube refrigerator / displacer displacement / space application / phase shift / energy distribution

Cite this article

Download citation ▾
Kongkuai YING, Wang YIN, Yinong WU, Zhenhua JIANG, Jiantang SONG, Shaoshuai LIU, Haifeng ZHU. Energy distribution between liquid hydrogen and liquid oxygen temperatures in a Stirling/pulse tube refrigerator. Front. Energy, 2023, 17(4): 516‒526 https://doi.org/10.1007/s11708-022-0844-6

References

[1]
Bruno C, Giucci S. Cryogenic technology to improve electric thrusters. Acta Astronautica, 2002, 51(12): 855–863
CrossRef Google scholar
[2]
RossR G. Aerospace coolers: a 50-year quest for long life cryogenic cooling in space. In: Timmerhaus K D, Reed R P, eds., Cryogenic Engineering: Fifty Years of Progress. New York: Springer, 2007
[3]
Getie M Z, Lanzetta F, Bégot S. . Reversed regenerative Stirling cycle machine for refrigeration application: a review. International Journal of Refrigeration, 2020, 118: 173–187
CrossRef Google scholar
[4]
Plachta D W, Johnson W L, Feller J R. Zero boil-off system testing. Cryogenics, 2016, 74: 88–94
CrossRef Google scholar
[5]
Wang B, Gan Z H. A critical review of liquid helium temperature high frequency pulse tube cryocoolers for space applications. Progress in Aerospace Sciences, 2013, 61: 43–70
CrossRef Google scholar
[6]
Conrad T, Schaefer B, Bellis L. . Raytheon long life cryocoolers for future space missions. Cryogenics, 2017, 88: 44–50
CrossRef Google scholar
[7]
PriceK DKirkconnell C S. Two Stage Hybrid Cryocooler Development. Cryocoolers 12. Boston: Springer US, 2003, 233–239
[8]
KirkconnellC SPriceK DBarrM C, . A Novel Multi-stage Expander Concept. Cryocoolers 11. Boston: Springer US, 2002, 259–263
[9]
Yang L W, Thummes G. High frequency two-stage pulse tube cryocooler with base temperature below 20 K. Cryogenics, 2005, 45(2): 155–159
CrossRef Google scholar
[10]
Gan Z H, Fan B Y, Wu Y Z. . A two-stage Stirling-type pulse tube cryocooler with a cold inertance tube. Cryogenics, 2010, 50(6–7): 426–431
CrossRef Google scholar
[11]
Dietrich M, Thummes G. Two-stage high frequency pulse tube cooler for refrigeration at 25 K. Cryogenics, 2010, 50(4): 281–286
CrossRef Google scholar
[12]
Chao Y, Wang B, Li H. . A two-stage thermally-coupled pulse tube cryocooler working at 35 K for space application. Acta Astronautica, 2022, 191: 193–203
CrossRef Google scholar
[13]
Liu S, Chen X, Zhang A. . Investigation on phase shifter of a 10 W/70 K inertance pulse tube refrigerator. International Journal of Refrigeration, 2017, 74: 450–457
CrossRef Google scholar
[14]
Zhi X, Qiu L, Pfotenhauer J M. . Refrigeration mechanism of the gas parcels in pulse tube cryocoolers under different phase angles. International Journal of Heat and Mass Transfer, 2016, 103: 382–389
CrossRef Google scholar
[15]
Kirkconnell C S, Hon R C, Kesler C H. . Raytheon Stirling/pulse tube cryocooler development. AIP Conference Proceedings, 2008, 985(1): 909–916
CrossRef Google scholar
[16]
KennethD PCarl S KStepthenC N. Single fluid Stirling pulse tube hybrid expander. US Patent, 6167707: B1, 2001
[17]
Finch A T, Price K D, Kirkconnell C S. Raytheon Stirling/pulse tube two-stage (RSP2) cryocooler advancements. AIP Conference Proceedings, 2004, 710(1): 1285–1292
CrossRef Google scholar
[18]
Hon R C, Kirkconnell C S, Shrago J A. . Raytheon RSP2 cryocooler low temperature testing and design enhancements. AIP Conference Proceedings, 2010, 1218(1): 371–380
CrossRef Google scholar
[19]
Schaefer B R, Bellis L, Ellis M J. . Raytheon’s next generation compact inline cryocooler architecture. AIP Conference Proceedings, 2014, 1537(1): 371–377
CrossRef Google scholar
[20]
Guo Y, Chao Y, Wang B. . The thermodynamic characteristics of a Stirling/pulse tube hybrid cryocooler. Cryogenics, 2018, 96: 133–143
CrossRef Google scholar
[21]
Chao Y, Guo Y, Wang Y. . Thermodynamic analysis of the working states of the Stirling/pulse tube hybrid cryocooler. Applied Thermal Engineering, 2020, 170: 115024
CrossRef Google scholar
[22]
Liu B, Jiang Z, Ying K. . A high efficiency Stirling/pulse tube hybrid cryocooler operating at 35 K/85 K. Cryogenics, 2019, 101: 137–140
CrossRef Google scholar
[23]
Liu B, Jiang Z, Ying K. . Numerical and experimental study on a Stirling/pulse tube hybrid refrigerator operating around 30 K. International Journal of Refrigeration, 2021, 123: 34–44
CrossRef Google scholar
[24]
Liu B, Jiang Z, Ying K. . Theoretical model of a Stirling/pulse tube hybrid refrigerator and its verification. Applied Thermal Engineering, 2021, 189: 116587
CrossRef Google scholar
[25]
RadebaughR. Development of the pulse tube refrigerator as an efficient and reliable cryocooler. Institute of Refrigeration Proceedings, 2000

Acknowledgements

This work was supported by the Hundred Talents Program of the Chinese Academy of Sciences, the National Natural Science Foundation of China (Grant No. 51806231), and the Strategic Priority Research Program of the Chinese Academy of Sciences (XDB35000000, XDB35040102).

Competing interests

The authors declare that they have no competing interests.

RIGHTS & PERMISSIONS

2022 Higher Education Press 2022
AI Summary AI Mindmap
PDF(1264 KB)

Accesses

Citations

Detail

Sections