Comprehensive wood dwelling tests for Post-and-Beam and Shear-Wall structures reflecting foundation boundaries
Kazuki Takaya, Kazuto Ota, Cem Yenidogan, Takehiro Takahashi, Shohei Yamada, Hisatoshi Kashiwa, Yosuke Kawamata, Kazuhiro Hayashi, Takuya Nagae
Comprehensive wood dwelling tests for Post-and-Beam and Shear-Wall structures reflecting foundation boundaries
This paper focuses on the ultimate state of three-story wood dwellings with high aspect ratios, which are increasing in Japan’s urban areas. Using shaking table test results from the 2019 full-scale shaking table test, a comprehensive study is conducted on the accuracy of evaluating ultimate state through the story shear failure mode at the first story, the tension fracture mode at the wall base of the first story, and foundation sliding mode on the soil. Methods evaluating the dynamic response behaviors of the building systems are also investigated. In the test, the current Japanese seismic design guidelines were applied, and two Grade-3 buildings were prepared. One adopted the Post-and-Beam structure (A-building), and the other the Shear-Wall structure (B-building). A series of tests planned very different physical boundary conditions surrounding their reinforced concrete (RC) mat foundations. The sills, column bases and wall bases of the upper wood structures were anchored to the RC foundations by steel anchor bolts, according to the current Allowable Stress Design (ASD) requirements. In the first stage, A-building equipped a Base-Isolation system, while B-building represented a generic foundation constructed on a 1.5m-height real soil ground by preparing a rigid soil box (Foundation-Soil system). In the second stage of A-building and B-building, the foundation was firmly fixed (Fixed-Foundation system), and shaking table motions were fully applied to the foundations. The entire test system was setup on the large shaking table facility at E-Defense, and a series of tests were conducted using JMA-Kobe motion and JR-Takatori motion recorded in the 1995 Kobe earthquake as Maximum-Considered-Earthquake motions. Confirmed was the change in the structural mechanism due to the upper structural systems and the foundation boundaries. Regarding the upper wood structure performance in the Fixed-Foundation system, a story shear failure mode was observed at the first story in A-building, while a tension fracture mode at the base of the first story in B-building. This difference of failure mode is difficult to determine with ASD. The maximum strength were more than four times higher than the ASD base shear force. Tension fracture capacity at the wall base was mainly enhanced by the presence of the steel anchor bolts. Regarding the foundation performance in Foundation-Soil system of B-building, a horizontal displacement up to 240mm was observed between the foundation and soil when JMA-Kobe 100% was applied. A response reduction effect was observed in the upper wood structure, similar to the Base-Isolation system of A-building. The initial friction and cyclic friction strength capacities between the foundation and soil were quantitatively evaluated considering the horizontal twodirectional sliding. The representative test results were converted to the corresponding SDOF systems based on the first mode response assessment. In the Fixed-Foundation system, the dynamic response characteristics of the upper wood structures were properly represented using Ibarra-Medina-Krawinkler pinching model in the equivalent SDOF system.
base isolation / foundation sliding / shaking table test / soil ground / ultimate strength / wood dwelling
[1] |
Yenidogan C, Nishi R, Nagae T, Inoue T, Kajiwara K. Full-scale cyclic test of a Japanese post and beam wood shearwall assembly. Bull Earthq Eng. 2020;18:4985-5008.
CrossRef
Google scholar
|
[2] |
Katsuhiko K, Kenji M. A study on hysteresis characteristics of full-scale wooden houses based on shaking table test. J Struct Eng B [in Japanese]. 2001;47B(3):341-348.
|
[3] |
Watahiki M, Machida K, Ohashi Y, Sakamoto I. Study on seismic performance of wood-framed residential structures by full-scale test. J Struct Constr Eng [in Japanese]. 2006;599:103-110.
CrossRef
Google scholar
|
[4] |
Miyake T, Minowa C, Isoda H, Koshihara M, Tsuchimoto T, Sakamoto I. Collapsing response analyses of existing wood houses corresponding to shaking table test. 10th World Conference on Timber Engineering. Miyazaki, Japan, June 2-5, 2008;1:1770-1777.
|
[5] |
Naohito K, Takahiro T, Yoshimitsu O, et al. Design methods and shaking table tests on 3-story wood houses by post and beam construction part 1: outline of series of test. AIJ Conv [in Japanese]. 2010;2010:229-230.
|
[6] |
Yenidogan C, Nishi R, Uwadan S, et al. Full-scale shake table tests of P&B type of Japanese three-story wood dwellings for the collapse characterization. Soil Dyn Earthq Eng. 2021;150:106898.
CrossRef
Google scholar
|
[7] |
Nagae T, Uwadan S, Yenigodan C, et al. The 2019 full-scale shake table test program of wood dwellings. 17th World Conference on Earthquake Engineering, Sendai, Japan, September 27-October 2, 2021.
|
[8] |
Nagae T, Uwadan S, Takaya K, et al. Sliding-Rocking Combined Actions at Base Foundation Influencing Global and Local Deformations of Upper Wood Structure: Proceedings, 17th World Conference on Earthquake Engineering, Sendai, Japan, September 27-October 2, 2021.
|
[9] |
Kabeyasawa T, Kabeyasawa T. A method of estimating earthquake responses of building structures on spread foundation with base slip behaviour. J Struct Constr Eng [in Japanese]. 2008;73(634):2151-2158.
CrossRef
Google scholar
|
[10] |
Kazuto M, Kazuya M, Masaki M. Development of seismic damage prediction method of wooden houses on spread foundation considering the effect of base slip. AIJ Tohoku Chapter Architectural Research Meeting [in Japanese], AIJ. Yamagata, Japan, June 19-20, 2010;73:171-174.
|
[11] |
Takahashi T, Nagae T, Uwadan S, et al. Stiffness, ultimate strength capacity and cyclic loading deterioration characteristics of two different wood-structure dwellings following the current japanese practice. 17th World Conference on Earthquake Engineering, Sendai, Japan, September 27-October 2, 2021.
|
[12] |
Tsuyoshi M, Naohito K, Hiroshi I, Toshio H, Yoshio I, Makoto K. Study on shaking table tests method of full scale wooden dwelling house part 24 outline of test for three-story wood framed construction. AIJ Conv [in Japanese]. 2007:543-544.
|
[13] |
Katsuhiko K, Miyamoto S, Nisimura A, Shigeto Y, Takata K, Miyazawa K. A study on full-scale shaking table test of wooden wall frame construction house. J Struct Eng [in Japanese]. 2001;47B:333-340.
|
[14] |
Hoshi M, Watanabe H, Nakazato M, Noguchi H. Full-scale vibration test of the building by wooden unit construction method (wood unit construction method). AIJ J Technol Des [in Japanese]. 2008;14(27):79-84.
CrossRef
Google scholar
|
[15] |
Building design guide for wood frame construction. Japan 2×4 home builders association [in Japanese]. November, 2018.
|
[16] |
Higashida T, Kato S, Nakazawa S. Structural characteristics consiering nonstructural elements based on shaking table test for two-story wooden framework of real size. J Struct Eng [in Japanese]. 2008;54B:67-76.
|
[17] |
Takaya K, Iwata H, Nagae T, et al. E-Defense test on functionality of three-story residential houses including underground pipe lines (Metropolitan resilience PJ) Part.30 comprehensive assessment for equivalent stiffness. AIJ Conv [in Japanese]. 2021;2021:295-296.
|
[18] |
Allowable stress design method of wood housings. Japan Housing &Wood Technology Center [in Japanese]. March, 2017.
|
[19] |
Structural design guidelines for wood frame construction. Japan 2×4 Home Builders Association [in Japanese]. November, 2018.
|
[20] |
Clough RW, Johnston SB. Effect of Stiffness Degradation on Earthquake Ductility Requirements. Japan Earthquake Engineering Symposium. JAEE, Tokyo, Japan, 1966;227-232.
|
[21] |
Takeda T, Sozen MA, Nielsen NN. Reinforced concrete response to simulated earthquakes. J Struct Div. 1970;96(12):2557-2573.
CrossRef
Google scholar
|
[22] |
Sivaselvan MV, Reinhorn AM. Hysteretic models for deteriorating inelastic structures. J Eng Mech. 2000;126(6):633-640.
CrossRef
Google scholar
|
[23] |
Song JK, Pincheira J. Spectral displacement demands of stiffness and strength degrading systems. Earthquake Spectra. 2000;16(4):817-851.
CrossRef
Google scholar
|
[24] |
Ibarra L. Global collapse of frame structures under seismic excitations. Ph.D. Dissertation, Department of Civil and Environmental Engineering. Stanford University;2003.
|
[25] |
Ibarra L, Krawinkler H, Vancouver BC. Global collapse of deteriorating mdof systems. 13th World Conference on Earthquake Engineering, Canada, August 1-6, 2004.
|
[26] |
Ibarra L, Medina RA, Krawinkler H. Hysteretic models that incorporate strength and stiffness deterioration. Earthquake Eng Struct Dyn. 2005;34(12):1489-1511.
CrossRef
Google scholar
|
[27] |
Ibarra L, Krawinkler H. Effects of Uncertainty in System Deterioration Parameters on the Variance of Collapse Capacity. 9th International Conference on Structural Safety and Reliability, Rome, June 19-23;2005.
|
[28] |
Krawinkler H, Zohrei M. Cumulative damage in steel structures subjected to earthquake ground motions. Comput Struct. 1983;16(1-4):531-541.
CrossRef
Google scholar
|
[29] |
Yenidogan C, Yokoyama R, Nagae T, Kajiwara K, Ghannoum W. Shake table test of a full-scale four-story reinforced concrete structure and numerical representationof overall response with modified IMK model. Bull Earthq Eng. 2017;16(5):4985-5008.
CrossRef
Google scholar
|
[30] |
Open System for Earthquake Engineering Simulation (OpenSEES). Pacific Earthquake Engineering Research Center. University of California;2009.
|
/
〈 | 〉 |