Coronary CT Angiography Using Low Iodine Delivery Rate and Tube Voltage Determined by Body Mass Index: Superiority in Clinical Practice

Wang Yuan , Ting-ting Qu , Hui-juan Wang , Mei-yu Wang , Yuan Qu , Gang Niu , Jian Yang

Current Medical Science ›› 2019, Vol. 39 ›› Issue (5) : 825 -830.

PDF
Current Medical Science ›› 2019, Vol. 39 ›› Issue (5) : 825 -830. DOI: 10.1007/s11596-019-2112-5
Article

Coronary CT Angiography Using Low Iodine Delivery Rate and Tube Voltage Determined by Body Mass Index: Superiority in Clinical Practice

Author information +
History +
PDF

Abstract

To explore the feasibility and superiority of iodine delivery rate (IDR) and tube voltage determined by patients’ body mass index (BMI) in coronary CT angiography (CCTA), a total of 1567 patients undertaking CCTA during Feb. and Dec. 2016 were enrolled and divided into two groups. In the control group, the IDR and tube voltage were fixed, while in the experimental group, the IDR and tube voltage were determined by patients’ BMI. The volume of iodinated contrast media (ICM), extravasation rate, extravasation volume, extravasation recovery interval, incidence rate of adverse reactions, effective dose (ED) and image quality of the two groups were compared. The experiments demonstrated that the ICM volume, extravasation rate, extravasation volume, extravasation recovery interval, incidence of adverse reactions and ED were lower or shorter in the experimental group than in the control group, and the differences were statistically significant (all P<0.05). However, there were no significant differences in the mean CT value, image noise, signal to noise ratio and contrast to noise ratio between the two groups (all P<0.05), which were consistent with the diagnosticians’ subjective evaluation outcomes. Our findings suggested that in CCTA, it is feasible to determine the IDR and tube voltage based on patients’ BMI; low tube voltage and IDR are superior to the fixed tube voltage and IDR and are worthy of clinical promotion.

Keywords

iodinated contrast media / iodine delivery rate / tube voltage / ICM extravasation / adverse reactions

Cite this article

Download citation ▾
Wang Yuan, Ting-ting Qu, Hui-juan Wang, Mei-yu Wang, Yuan Qu, Gang Niu, Jian Yang. Coronary CT Angiography Using Low Iodine Delivery Rate and Tube Voltage Determined by Body Mass Index: Superiority in Clinical Practice. Current Medical Science, 2019, 39(5): 825-830 DOI:10.1007/s11596-019-2112-5

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

BöhmI, NairzK, MorelliJN, et al.. Iodinated contrast media and the alleged “iodine allergy”: an inexact diagnosis leading to inferior radiologic management and adverse drug reactions. Rofo, 2017, 189(4): 326-332

[2]

NashK, HafeezA, HouS, et al.. Hospital-acquired renal insufficiency. Am J Kidney Dis, 2002, 39(5): 930-936

[3]

YuM, MaY, WangY, et al.. Comparison of image quality among different low dose contrast materials injection protocols in coronary CT angiography. J Chin Clin Med Imaging, 2015, 26(11): 779-783

[4]

SunZ, FuQ, CaoL, et al.. Intravenous N-acetylcysteine for prevention of contrast-induced nephropathy: a meta-analysis of randomized, controlled trials. PLoS One, 2013, 8(1): e55124

[5]

MaoYJ, YeWQ, TianMM, et al.. Study on nursing management of intravenous extravasation of iodine contrast medium. Chin Nurs Manag, 2010, 10(4): 63-65

[6]

WangQS, LiangCH. Adverse reactions of iodinated contrast agents and the strategies for their treatment. Shanghai Med J, 2014, 35(13): 8-15

[7]

IyerRS, SchoppJG, SwansonJO, et al.. Safety essentials: acute reactions to iodinated contrast media. Can Assoc Radiol J, 2013, 64(3): 193-199

[8]

LiaoWH. Progress in prevention and nursing of contrast medium extravasation in enhanced CT scanning. Quan Ke Hu Li (Chinese), 2016, 14(17): 1759-1762

[9]

GhoshhajraBB, EngelLC, KárolyiM, et al.. Cardiac computed tomography angiography with automatic tube potential selection: effects on radiation dose and image quality. J Thorac Imaging, 2013, 28(1): 40-48

[10]

KokM, MihlC, SeehofnerováA, et al.. Automated tube voltage selection for radiation dose reduction in CT angiography using different contrast media concentrations and a constant iodine delivery rate. AJR Am J Roentgenol, 2015, 205(6): 1332-1338

[11]

KokM, MihlC, HendriksBMF, et al.. Optimizing contrast media application in coronary CT angiography at lower tube voltage: Evaluation in a circulation phantom and sixty patients. Eur J Radiol, 2016, 85(6): 1068-1074

[12]

LellMM, JostG, KorporaalJG, et al.. Optimizing contrast media injection protocols in state-of-the art computed tomographic angiography. Invest Radiol, 2015, 50(3): 161-167

[13]

LellMM, FleischmannU, PietschH, et al.. Relationship between low tube voltage (70 kV) and the iodine delivery rate (IDR) in CT angiography: An experimental in-vivo study. PLoS One, 2017, 12(3): e0173592

[14]

BaeKT. Intravenous contrast medium administration and scan timing at CT: considerations and approaches. Radiology, 2010, 256(1): 32-61

[15]

JohnsonPT, PannuHK, FishmanEK. IV contrast infusion for coronary artery CT angiography: literature review and results of a nationwide survey. AJR Am J Roentgenol, 2009, 192(5): W214-221

[16]

BaeKT, TranHQ, HeikenJP. Uniform vascular contrast enhancement andreduced contrast medium volume achieved by using exponentially decelerated contrast material injection method. Radiology, 2004, 231(3): 732-736

[17]

HausleiterJ, MeyerT, HadamitzkyM, et al.. Radiation dose estimates from cardiac multislice computed tomography in daily practice: impact of different scanning protocols oneffective dose estimates. Circulation, 2006, 113(10): 1305-1310

[18]

FeuchtnerGM, JodocyD, KlauserA, et al.. Radiation dose reduction by using 100-kV tubevoltage in cardiac 64-slice computed tomography: a comparative study. Eur J Radiol, 2010, 75(1): e51-e56

[19]

KanematsuM, GoshimaS, MiyoshiT, et al.. Whole-body CT angiography with low tube voltage and low-concentration contrast material to reduce radiation dose and iodine load. AJR Am J Roentgenol, 2014, 202(1): W106-116

[20]

Sistrom CL, Gay SB, Peffley L. Extravasation of iopamidol and iohexol during contrast-enhanced CT: report of 28 cases. Radiology, 1991(180):707–710

[21]

HouQF, GaoL, LiuS. Identification and treatment of angio extravasation of contrast agents. China JMIT, 1999, 15(9): 732-733

[22]

BottinorW, PolkampallyP, JovinI. Adverse reactions to iodinated contrast media. Int J Angiol, 2013, 22(3): 149-154

[23]

KellerM, LerchM, BritschgiM, et al.. Processing-dependent and -independent pathways for recognition of iodinated contrast media by specific human T cells. Clin Exp Allergy, 2010, 40(2): 257-268

[24]

KatayamaH, YamaguchiK, KozukaT, et al.. Adverse reactions to ionic and nonionic contrast media. A report from the Japanese committee on the safety of contrast media. Radiology, 1990, 175(3): 621-628

[25]

YuL, BruesewitzMR, ThomasKB, et al.. Optimal tube potential for radiation dose reduction in pediatric CT: principles, clinical implementations, and pitfalls. Radiographics, 2011, 31(3): 835-848

[26]

FanWP, LiSW, DingJ, et al.. Individualized contrast medium injection protocols for coronary CT angiography. Chin Med Pharm, 2013, 3(12): 110-112

AI Summary AI Mindmap
PDF

109

Accesses

0

Citation

Detail

Sections
Recommended

AI思维导图

/