Application of the Guiding Template Designed by Three-dimensional Printing Data for the Insertion of Sacroiliac Screws: a New Clinical Technique

Yi Liu , Wu Zhou , Tian Xia , Jing Liu , Bo-bin Mi , Liang-cong Hu , Zeng-wu Shao , Guo-hui Liu

Current Medical Science ›› 2018, Vol. 38 ›› Issue (6) : 1090 -1095.

PDF
Current Medical Science ›› 2018, Vol. 38 ›› Issue (6) : 1090 -1095. DOI: 10.1007/s11596-018-1988-9
Article

Application of the Guiding Template Designed by Three-dimensional Printing Data for the Insertion of Sacroiliac Screws: a New Clinical Technique

Author information +
History +
PDF

Abstract

This study is aimed to explore the clinical application of the guiding template designed by three-dimensional printing data for the insertion of sacroiliac screws. A retrospective study of 7 cases (from July 2016 to December 2016), in which the guiding template printed by the threedimensional printing technique was used for the insertion of sacroiliac screws of patients with posterior ring injuries of pelvis, was performed. Totally, 4 males and 3 females were included in template group, aged from 38 to 65 years old (mean 50.86±8.90). Of them, 5 had sacral fractures (3 with Denis type I and 2 with type II) and 2 the separation of sacroiliac joint. Guiding templates were firstly made by the three-dimensional printing technique based on the pre-operative CT data. Surgical operations for the stabilization of pelvic ring by applying the guiding templates were carried out. A group of 8 patients with sacroiliac injuries treated by percutaneous sacroiliac screws were analyzed as a control group retrospectively. The time of each screw insertion, volume of intra-operative blood loss, and the exposure to X ray were analyzed and the Matta’s radiological criteria were used to evaluate the reduction quality. The Majeed score was used to evaluate postoperative living quality. The visual analogue scale (VAS) was applied at different time points to judge pain relief of coccydynia. All the 7 patients in the template group were closely followed up radiographically and clinically for 14 to 20 months, mean (16.57±2.44) months. Totally 9 sacroiliac screws for the S1 and S2 vertebra were inserted in the 7 patients. The time length for each screw insertion ranged from 450 to 870 s, mean (690.56±135.68) s, and the number of times of exposure to X ray were 4 to 8, mean (5.78±1.20). The intra-operative blood loss ranged from 45 to 120 mL, mean (75±23.32) mL. According to Matta’s radiology criteria, the fracture and dislocation reduction were excellent in 6 cases and good in 1. The pre-operative VAS score ranged from 5.2 to 8.1, mean (7.13±1.00). The average one-week/six-month post-operative VAS was (5.33±0.78) and (1.33±0.66), respectively (P<0.05 when compared with pre-operative VAS). The 12-month postoperative Majeed score ranged from 86 to 92, mean (90.29±2.21). The three-dimensional printed guiding template for sacroiliac screw insertion, which could significantly shorten the operation time, provide a satisfied outcome of the stabilization of the pelvic ring, and protect doctors and patients from X-ray exposure, might be a practical and valuable new clinical technique.

Keywords

sacroiliac screws / three-dimensional printing technique / posterior pelvic ring injury / guiding template

Cite this article

Download citation ▾
Yi Liu, Wu Zhou, Tian Xia, Jing Liu, Bo-bin Mi, Liang-cong Hu, Zeng-wu Shao, Guo-hui Liu. Application of the Guiding Template Designed by Three-dimensional Printing Data for the Insertion of Sacroiliac Screws: a New Clinical Technique. Current Medical Science, 2018, 38(6): 1090-1095 DOI:10.1007/s11596-018-1988-9

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

MattaJM, SaucedoT. Internal fixation of pelvic ring fractures. Clin Orthop Relat Res, 1989, 242: 83-97

[2]

ShulerTE, BooneDC, GruenGS, et al.. Percutaneous iliosacral screw fixation: early treatment for unstable posterior pelvic ring disruptions. J Trauma, 1995, 38(3): 453-458

[3]

van den BoschEW, van ZwienenCM, van VugtAB. Fluoroscopic positioning of sacroiliac screws in 88 patients. J Trauma, 2002, 53(1): 44-48

[4]

RouttMLJr, SimonianPT, MillsWJ. Iliosacral screw fixation: early complications of the percutaneous technique. J Orthop Trauma, 1997, 11(8): 584-589

[5]

PieskeC, LandersdorferC, TrummC, et al.. CT-guided sacroiliac percutaneous screw placement in unstable posterior pelvic ring injuries: Accuracy of screw position, injury reduction and complications in 71 patients with 136 screws. Injury, 2015, 46(2): 333-339

[6]

TakaoM, NishiiT, SakaiT, et al.. Iliosacral screw insertion using CT-3D-fluoroscopy matching navigation. Injury, 2014, 45(6): 988-994

[7]

BehrendtD, MutzeM, SteinkeH, et al.. Evaluation of 2D and 3D navigation for iliosacral screw fixation. Int J Comput Assist Radiol Surg, 2012, 7(2): 249-255

[8]

HellerM, BauerHK, GoetzeE, et al.. Applications of patient-specific 3D printing in medicine. Int J Comput Dent, 2016, 19(4): 323-339

[9]

LimCGT, CampbellDI, CookN, et al.. A case series of rapid prototyping and intraoperative imaging in orbital reconstruction. Craniomaxillofac Trauma Reconstr, 2015, 8(2): 105-110

[10]

StarosolskiZA, KanJH, RosenfeldSD, et al.. Application of 3-D printing (rapid prototyping) for creating physical models of pediatric orthopedic disorders. Pediatr Radiol, 2014, 44(2): 216-221

[11]

PowersMK, LeeBR, SilbersteinJ. Three-dimensional printing of surgical anatomy. Curr Opin Urol, 2016, 26(3): 283-288

[12]

JastiferJR, GustafsonPA. Three-Dimensional Printing and Surgical Simulation for Preoperative Planning of Deformity Correction in Foot and Ankle Surgery. J Foot Ankle Surg, 2017, 56(1): 191-195

[13]

UpexP, JouffroyP, RiouallonG. Application of 3D printing for treating fractures of both columns of the acetabulum: Benefit of pre-contouring plates on the mirrored healthy pelvis. Orthop Traumatol Surg Res, 2017, 103(3): 331-334

[14]

KimD, LimJY, ShimKW. Sacral Reconstruction with a 3D-Printed Implant after Hemisacrectomy in a Patient with Sacral Osteosarcoma: 1-Year Follow-Up Result. Yonsei Med J, 2017, 58(2): 453-457

[15]

MainiL, SharmaA, JhaS, et al.. Three-dimensional printing and patient-specific pre-contoured plate: future of acetabulum fracture fixation?. Eur J Trauma Emerg Surg, 2018, 44(2): 215-224

[16]

GuoF, DaiJ, ZhangJ, et al.. Individualized 3D printing navigation template for pedicle screw fixation in upper cervical spine. PLoS One, 2017, 12(2): e0171509

[17]

ChenXJ, XuL, YangY, et al.. A semi-automatic computer-aided method for surgical template design. Sci Rep, 2016, 6: 20280

[18]

PhilipT, JanV, PaulG, et al.. 3D-printing techniques in a medical setting: a systematic literature review. BioMed Eng Online, 2016, 15(1): 115

[19]

KimJW, OhCW, OhJK, et al.. The incidence of and factors affecting iliosacral screw loosening in pelvic ring injury. Arch Orthop Trauma Surg, 2016, 136(7): 921-927

[20]

Giráldez-SánchezMA, Lázaro-Gonzálvez, Martínez-ReinaJ, et al.. Percutaneous iliosacral fixation in external rotational pelvic fractures. A biomechanical analysis. Injury, 2015, 46(2): 327-332

[21]

RadetzkiF, WohlrabD, GoehreF, et al.. Anatomical conditions of the posterior pelvic ring regarding bisegmental transverse sacroiliac screw fixation: a 3D morphometric study of 125 pelvic CT datasets. Arch Orthop Trauma Surg, 2014, 134(8): 1115-1120

AI Summary AI Mindmap
PDF

96

Accesses

0

Citation

Detail

Sections
Recommended

AI思维导图

/