A new method of 3-dimensional localization of intraocular foreign bodies using CT imaging: A role of optic nerve

Qi Yao , Han-ping Wu , Bin Xiong , Ping Han , Chuan-sheng Zheng

Current Medical Science ›› 2017, Vol. 37 ›› Issue (1) : 110 -114.

PDF
Current Medical Science ›› 2017, Vol. 37 ›› Issue (1) : 110 -114. DOI: 10.1007/s11596-017-1703-2
Article

A new method of 3-dimensional localization of intraocular foreign bodies using CT imaging: A role of optic nerve

Author information +
History +
PDF

Abstract

Computed tomography (CT) is considered the most sensitive method for the detection of intraocular foreign bodies (IOFBs). The purpose of this study was to evaluate a new method of 3-dimentional (3D) localization of IOFBs that takes advantage of the anatomical structure of the optic nerve and to assess the clinical outcomes using this new method. Twenty-two trauma patients with IOFBs or suspected IOFBs admitted to our hospital were scanned with multislice CT (MSCT) between July and December 2003. All scanning was performed with a 16-row spiral CT in axial plane using a sequential scanning protocol. During the scanning, the eyeball of the patient was kept stable and was not allowed to rotate internally or externally. Section collimation was set at 16 mm × 0.75 mm. Table feed was 12 mm. Reconstruction index was 0.75 mm. After scanning, the reconstructed images were loaded into a workstation to create the multiplanar reconstruction images with the aid of the 3D software. We compared the localization results with the operative findings. Multiplanar reconstruction images showed IOFBs in all 22 patients. IOFBs occurred in the eyeball of 14 patients, in the wall of the eyeball of 5 patients and in the posterior orbits of 3 patients. Different surgical procedures were designed according to the localization by this new method and all IOFBs were successfully removed. All of these foreign bodies were metallic and the localization of IOFB using MSCT was consistent with that found by operative findings. It was suggested that MSCT is a simple and effective imaging modality for the localization of IOFBs. In our study, we localized the IOFBs more quickly and accurately by taking advantage of the fixed position of the intraocular segment of the optic nerve, and determined the necessary surgical parameters.

Keywords

multislice computed tomography / intraocular foreign body / localization / optic nerve

Cite this article

Download citation ▾
Qi Yao, Han-ping Wu, Bin Xiong, Ping Han, Chuan-sheng Zheng. A new method of 3-dimensional localization of intraocular foreign bodies using CT imaging: A role of optic nerve. Current Medical Science, 2017, 37(1): 110-114 DOI:10.1007/s11596-017-1703-2

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

ShockJP, AdamsD. Long-term visual acuity results after penetrating and perforating ocular injuries. Am J Ophthalmol, 1985, 100(5): 714-718 PMID: 4061553

[2]

ThompsonJT, ParverLM, EngerCL, et al. . Infectious endophthalmitis after penetrating injuries with retained intraocular foreign bodies. Ophthalmology, 1993, 100(10): 1468-1474 PMID: 8414406

[3]

YehS, ColyerMH, WeichelED. Current trends in the management of intraocular foreign bodies. Curr Opin Ophthalmol, 2008, 19(3): 225-233 PMID: 18408498

[4]

GrevenCM, EngelbrechtNE, SlusherMM, et al. . Intraocular foreign bodies: management, prognostic factors, and visual outcomes. Ophthalmology, 2000, 107(3): 608-612 PMID: 10711903

[5]

AdesanyaOO, DawkinsDM. Intraorbital wooden foreign body (IOFB): mimicking air on CT. Emerg Radiol, 2007, 14(1): 45-49 PMID: 17265026

[6]

MielerWF, EllisMK, WilliamsDF, et al. . Retained intraocular foreign bodies and endophthalmitis. Ophthalmology, 1990, 97(11): 1532-1538 PMID: 2255525

[7]

WilliamsDF, MielerWF, AbramsGW. Intraocular foreign bodies in young people. Retina, 1990, 10: S45-S49 PMID: 2353137

[8]

JonasJB, KnorrHL, BuddeWM. Prognostic factors in ocular injuries caused by intraocular or retrobulbar foreign bodies. Ophthalmology, 2000, 107(5): 823-828 PMID: 10811069

[9]

LinTC, LiaoTC, YuanWH, et al. . Management and clinical outcomes of intraocular foreign bodies with the aid of orbital computed tomography. J Chin Med Assoc., 2014, 77(8): 433-436 PMID: 25028294

[10]

Boncoeur-MartelMP, AdenisJP, RulfiJY, et al. . CT appearances of chronically retained wooden intraorbital foreign bodies. Neuroradiology, 2001, 43(2): 165-168 PMID: 11326566

[11]

FulcherTP, McNabAA, SullivanTJ. Clinical features and management of intraorbital foreign bodies. Ophthalmology, 2002, 109(3): 494-500 PMID: 11874750

[12]

LitES, YoungLH. Anterior and posterior segment intraocular foreign bodies. Int Ophthalmol Clin, 2002, 42(3): 107-120 PMID: 12131588

[13]

ParkeDW, PathengayA, FlynnHW, et al. . Risk factors for endophthalmitis and retinal detachment with retained intraocular foreign bodies. J Ophthalmol, 2012, 2012(2): 101-112

[14]

PintoA, BruneseL, DanieleS, et al. . Role of Computed Tomography in the Assessment of Intraorbital Foreign Bodies. Semin Ultrasound CT &MR, 2012, 33(5): 392-395

[15]

MeteG, TurgutY, OsmanA, et al. . Anterior segment intraocular metallic foreign body causing chronic hypopyon uveitis. J Ophthalmic Inflamm Infect, 2011, 1(2): 85-87 PMID: 21484173

[16]

RubinsteinA, RiddellCE, Kafil-HussainN, et al. . Self-inserted intraorbital foreign bodies. Ophthal Plast Reconstr Surg, 2005, 21(2): 156-157 PMID: 15778674

[17]

HoweL, JonesNS. Guidelines for the management of periorbital cellulitis/abscess. Clin Otolaryngol Allied Sci, 2004, 29(6): 725-728 PMID: 15533168

[18]

MichonJ, LiuD. Intraorbital foreign bodies. Semin Ophthalmol, 1994, 9(3): 193-199 PMID: 10155639

[19]

LakitsA, ProkeschR, ScholdaC, et al. . Orbital helical computed tomography in the diagnosis and management of eye trauma. Ophthalmology, 1999, 106(12): 2330-2335 PMID: 10599667

[20]

ChackoJG, FigueroaRE, JohnsonMH, et al. . Detection and localization of steel intraocular foreign bodies using computed tomography. Ophthalmology, 1997, 104(2): 319-323 PMID: 9052639

[21]

HoffstetterP, SchreyerAG, SchreyerCI, et al. . Multidetector CT (MD-CT) in the diagnosis of uncertain open globe injuries. Rofo, 2010, 182(2): 151-154 PMID: 19859864

[22]

ShiHS, ZhengJL, HanP, et al. . The application of CT multiplanar reconstruction to the measuring and localizing of intraocular metal foreign bodies. J Clin Radiol, 2001, 20(10): 743-745

[23]

GanW, ZhaoJN. Study of Spiral CT in the Localization and Measurement of Intraocular Foreign Body. J Prac Radiol, 2006, 22(9): 1143-1144

[24]

GuanHJ, GongQR. The basis of modern ophthalmology. Beijing: People’ s Military Medical Publisher, 1998151

[25]

LiFM. Ophthalmology of China. Beijing: People’s Medical Publishing House, 2005107

[26]

MatsubaS, TabuchiH, KurusuA. Effectiveness of 3D-CT in an accurate preoperative diagnosis and improving safety of vitrectomy for intraocular foreign body. Acta Ophthalmol, 2013, 91(5): 487-488 PMID: 22429590

[27]

LakitsA, SteinerE, ScholdaC, et al. . Evaluation of intraocular foreign bodies by spiral computed tomography and mutiplanar reconstruction. Ophthalmology, 1998, 105(2): 307-312 PMID: 9479292

AI Summary AI Mindmap
PDF

118

Accesses

0

Citation

Detail

Sections
Recommended

AI思维导图

/