Cardiovascular cast model fabrication and casting effectiveness evaluation in fetus with severe congenital heart disease or normal heart

Yu Wang , Hai-yan Cao , Ming-xing Xie , Lin He , Wei Han , Liu Hong , Yuan Peng , Yun-fei Hu , Ben-cai Song , Jing Wang , Bin Wang , Cheng Deng

Current Medical Science ›› 2016, Vol. 36 ›› Issue (2) : 259 -264.

PDF
Current Medical Science ›› 2016, Vol. 36 ›› Issue (2) : 259 -264. DOI: 10.1007/s11596-016-1577-8
Article

Cardiovascular cast model fabrication and casting effectiveness evaluation in fetus with severe congenital heart disease or normal heart

Author information +
History +
PDF

Abstract

To investigate the application and effectiveness of vascular corrosion technique in preparing fetal cardiovascular cast models, 10 normal fetal heart specimens with other congenital disease (control group) and 18 specimens with severe congenital heart disease (case group) from induced abortions were enrolled in this study from March 2013 to June 2015 in our hospital. Cast models were prepared by injecting casting material into vascular lumen to demonstrate real geometries of fetal cardiovascular system. Casting effectiveness was analyzed in terms of local anatomic structures and different anatomical levels (including overall level, atrioventricular and great vascular system, left-sided and right-sided heart), as well as different trimesters of pregnancy. In our study, all specimens were successfully casted. Casting effectiveness analysis of local anatomic structures showed a mean score from 1.90±1.45 to 3.60±0.52, without significant differences between case and control groups in most local anatomic structures except left ventricle, which had a higher score in control group (P=0.027). Inter-group comparison of casting effectiveness in different anatomical levels showed no significant differences between the two groups. Intra-group comparison also revealed undifferentiated casting effectiveness between atrioventricular and great vascular system, or left-sided and right-sided heart in corresponding group. Third-trimester group had a significantly higher perfusion score in great vascular system than second-trimester group (P=0.046), while the other anatomical levels displayed no such difference. Vascular corrosion technique can be successfully used in fabrication of fetal cardiovascular cast model. It is also a reliable method to demonstrate three-dimensional anatomy of severe congenital heart disease and normal heart in fetus.

Keywords

severe congenital heart disease / fetus / cast model / anatomy / casting effectiveness / perfusion

Cite this article

Download citation ▾
Yu Wang, Hai-yan Cao, Ming-xing Xie, Lin He, Wei Han, Liu Hong, Yuan Peng, Yun-fei Hu, Ben-cai Song, Jing Wang, Bin Wang, Cheng Deng. Cardiovascular cast model fabrication and casting effectiveness evaluation in fetus with severe congenital heart disease or normal heart. Current Medical Science, 2016, 36(2): 259-264 DOI:10.1007/s11596-016-1577-8

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

HoffmanJI, KaplanS. The incidence of congenital heart disease. J Am Coll Cardiol, 2002, 39(12): 1890-1900 PMID: 12084585

[2]

van VelzenCL, ClurSA, RijlaarsdamM, et al. . Prenatal detection of congenital heart disease-results of a national screening programme. BJOG, 2016, 123(3): 400-407 PMID: 25625301

[3]

ClurSA, Van BrusselPM, OttenkampJ, et al. . Prenatal diagnosis of cardiac defects: accuracy and benefit. Prenat Diagn, 2012, 32(5): 450-455 PMID: 22495905

[4]

HosslerF. Vascular corrosion casting. Microscopy Microanalysis, 2003, 9: 1578-1579

[5]

LiuH, ZhouJ, FengQL, et al. . Fetal echocardiography for congenital heart disease diagnosis: a meta-analysis, power analysis and missing data analysis. Eur J Prev Cardiol, 2015, 22(12): 1531-1547 PMID: 25258423

[6]

LinX, ChenD, JinY, et al. . Angioarchitecture of extracranial arteriovenous malformations: a vascular casting study. Ann Plast Surg, 2014, 73: S43-48 PMID: 25115376

[7]

AckermannM, KonerdingMA. Vascular casting for the study of vascular morphogenesis. Methods Mol Biol, 2015, 1214(1214): 49-66 PMID: 25468599

[8]

DebbautC, SegersP, CornillieP, et al. . Analyzing the human liver vascular architecture by combining vascular corrosion casting and micro-CT scanning: a feasibility study. J Anat, 2014, 224(4): 509-517 PMID: 24433401 PMCID: 4098684

[9]

LorentziadisM, ChamogeorgakisT, ToumpoulisIK, et al. . Topographic anatomy of bronchial arteries in the pig: a corrosion cast study. J Anat, 2005, 207(4): 427-432 PMID: 16191170 PMCID: 1571548

[10]

CookAC, FaggNL, AllanLD. Use of casts in the necropsy diagnosis of fetal congenital heart disease. Br Heart J, 1992, 68(5): 481-484 PMID: 1467033 PMCID: 1025192

[11]

HanW, XieM, ChengTO, et al. . The vital role the ductus arteriosus plays in the fetal diagnosis of congenital heart disease: Evaluation by fetal echocardiography in combination with an innovative cardiovascular cast technology. Int J Cardiol, 2016, 202: 90-96 PMID: 26386931

[12]

AchironR, RotsteinZ, HeggeshJ, et al. . Anomalies of the fetal aortic arch: a novel sonographic approach to in-utero diagnosis. Ultrasound Obstet Gynecol, 2002, 20(6): 553-557 PMID: 12493043

[13]

KiserudT, AcharyaG. The fetal circulation. Prenat Diagn, 2004, 24(13): 107-112

[14]

TorvidK. Physiology of the fetal circulation. Semin Fetal Neonatal Med, 2005, 10(10): 493-503

[15]

StruijkPC, HannekeM, MathewsJV, et al. . Fetal aortic distensibility, compliance and pulse pressure assessment during the second half of pregnancy. Ultrasound Med Biol, 2013, 39(11): 1966-1975 PMID: 23988265

[16]

ReddyPA, DouglasJE, SchulteM, et al. . The effect of prefixation on the quality of vascular corrosion casts of rat heart. Cardiovas Pathol, 1995, 4(4): 133-140

[17]

SimsPA, AlbrechtRM. Improved tissue corrosion of vascular casts: a quantitative filtration method used to compare tissue corrosion in various concentrations of sodium and potassium hydroxide. Scanning Microsc, 1993, 7(2): 637-643 PMID: 8108679

[18]

FahrenbachWH, BaconDR, MorrisonJC, et al. . Controlled vascular corrosion casting of the rabbit eye. J Electron Microsc Tech, 1988, 10(1): 15-26 PMID: 3193238

AI Summary AI Mindmap
PDF

93

Accesses

0

Citation

Detail

Sections
Recommended

AI思维导图

/