Preparation of thrombosis-targeted lipid microbubbles and determination of rabbit carotid artery thrombosis by microbubbles ultrasonogaphy

Wei-ming Xu , Min Feng , Hong-yang Zhao , Ming-xing Xie , Wei-yong Li , Rong Fu

Current Medical Science ›› 2013, Vol. 33 ›› Issue (1) : 146 -152.

PDF
Current Medical Science ›› 2013, Vol. 33 ›› Issue (1) : 146 -152. DOI: 10.1007/s11596-013-1088-9
Article

Preparation of thrombosis-targeted lipid microbubbles and determination of rabbit carotid artery thrombosis by microbubbles ultrasonogaphy

Author information +
History +
PDF

Abstract

A kind of thrombus-targeted lipid-coated microbubbles were prepared, and the target property of the microbubbles and the effects of different methods detecting thrombosis in vessels were observed. Phospholipid-coated microbubbles were prepared by membrane-hydration method. Thrombus-targeted lipid-coated fluorocarbon microbubbles were labeled with specific fluorescence and then integrated to the thrombus in vivo and ex vivo through an avidin biotin system. The thrombus was immediately observed for the distribution and property of the thrombus-targeted microbubbles under the optical microscope, fluorescence microscope and transmission electron microscope. The carotid thrombosis models were set up in rabbits, and the effects of different methods detecting thrombosis in vessels were observed. The diameter of the phospholipid-coated microbubbles was 0.8–2.5 μm, and even reached nanoscale in some of them. The zeta electric potential was about −11 mV and the concentration was about 1.08×1010/mL. Immunofluorescence of rapid frozen sections in vivo and ex vivo showed that massive targeted lipid-coated microbubbles flocked around fresh blood clots and some aggregated within them under the light and fluorescence microscope. The number of aggregated microbubbles ex vivo was greater than that observed in the experiment in vivo, and the fluorescence observed in the experiment ex vivo was stronger than that in the experiment in vivo. The same imaging was observed under the electron microscope. Models of carotid thrombosis in rabbits were established successfully. Effects of detecting thrombosis by means of thrombosis-targeted microbubble ultrasonoraphy and Sono Vue ultrasonography in vessels were more satisfactory than those by Color Doplor Flow Imaging (CDFI), ordinary microbubbles and Three Dimensions-time of flight MR angiography (3D-TOF-MRA) (P<0.01). Compared to ordinary microbubbles ultrasonography, thrombosis-targeted microbubbles ultrasonography had the advantages whenever in imaging quality or in imaging time. Thrombus-targeted phospholipid-coated microbubbles were prepared successfully by membrane-hydration method. They could aggregate rapidly in fresh blood clots and enter deep into the internal part of the thrombus both in vivo and ex vivo, and had the targeted property of strongly conjugating with the thrombus. Compared to other thrombosis detection methods, ultrasonography with thrombosis-targeted microbubbles has obvious advantages in detecting thrombosis in vessels, mainly in: non-invasiveness, safety, good image quality, accuracy, and longer imaging time.

Keywords

thrombus-targeted phospholipid-coated microbubbles / fluorescence detection / electron microscope / thrombus / magnetic resonance angiography

Cite this article

Download citation ▾
Wei-ming Xu, Min Feng, Hong-yang Zhao, Ming-xing Xie, Wei-yong Li, Rong Fu. Preparation of thrombosis-targeted lipid microbubbles and determination of rabbit carotid artery thrombosis by microbubbles ultrasonogaphy. Current Medical Science, 2013, 33(1): 146-152 DOI:10.1007/s11596-013-1088-9

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

BekeredjianR., ChenS., PanW., et al.. Effects of ultrasound-targeted microbubble destruction on cardiac gene expression. Ultrasound Med Biol, 2004, 30(4): 539-543

[2]

XiaH.M., GaoY.H., BianA.N., et al.. Evaluation of thrombus-targeted ultrasound contrast agent: Preliminary in vitro study. Zhongguo Chaosheng Yixue Zazhi (Chinese), 2004, 20(5): 321-323

[3]

KlibanovA.L., HughesM.S., VillanuevaF.S., et al.. Targeting and ultrasound imaging of microbubbles based contrast agents. MAGMA, 1999, 8(3): 177-184

[4]

OrthR.N., ClarkT.G., CraigheadH.G.. Avidin-biotin micro-patterning methods for biosensor applications. Biomed Microdevices, 2003, 5(1): 29-34

[5]

WilchekM., BayerE.A., YamadaS., et al.. Introduction to avidin-biotin technology. Methods Enzymol, 1990, 184(1): 5-13

[6]

WilchekM., BayerE.A., YamadaS., et al.. Application of avidin-biotin technology: literature survey. Methods Enzymol, 1990, 184(1): 14-25

[7]

ChenL., SchechterB.A., ArnonR.L., et al.. Tissue selective affinity targeting using the avidin-biotin system. Drug Dev Res, 2000, 50(1): 258-271

[8]

LuW.Y., LiuM., PanJ., et al.. Preparation of folate-liposome and its delivery into cultured HeLa cells. J Shanghai Med Univ (Chinese), 2000, 27(1): 4-8

[9]

BianA.N., GaoY.H., TanK.B., et al.. Study on immunological properties of human hepatocellular carcinoma-targeted liposome microbubbles. Zhonghua Chaosheng Zazhi (Chinese), 2004, 13(9): 696-699

[10]

LiZ.S., ZhouJ.P., WangL.L.. Study on the tumor targeting of RGD-PEG-liposomes. China Pharmacy (Chinese), 2003, 14(7): 393-394

[11]

UngerE., McCreeryT.P., SweitzerR.H., et al.. In vitro studies of a new thrombus-specific ultrasound contrast agent. Am J Cardiol, 1998, 81(12A): 58G-61G

[12]

UngerE., MetzgerP., KrupinskiE., et al.. The use of a thrombus specific ultrasound contrast agent to detect thrombus in arteriovenous fistulae. Invest Radiol, 2000, 35(1): 86-89

[13]

TakeuchiM., OgunyankinK., PandianN.G., et al.. Enhanced visualization of intravascular and left atrial appendage thrombus with the use of a thrombus-targeting ultrasonographic contrast agent (MRX-408A1): in vivo experimental echocardiographic studies. J Am Soc Echocardiogr, 1999, 12(12): 1015-1021

AI Summary AI Mindmap
PDF

91

Accesses

0

Citation

Detail

Sections
Recommended

AI思维导图

/