Evaluation of atrial septal defect using real-time three-dimensional echocardiography: Comparison with surgical findings

Saumu Tobbi Mweri , Youbin Deng , Peixuan Cheng , Hanhua Lin , Hongwei Wang , Ommari Baaliy Mkangara , Zhi Xia , Xiufen Hu , Xiaojun Bi , Yuhan Wu , Mustaafa Bapumiia , Weihui Shentu , Rong Liu , Yani Li , Meihua Zhu

Current Medical Science ›› 2009, Vol. 29 ›› Issue (2) : 257 -259.

PDF
Current Medical Science ›› 2009, Vol. 29 ›› Issue (2) : 257 -259. DOI: 10.1007/s11596-009-0225-y
Article

Evaluation of atrial septal defect using real-time three-dimensional echocardiography: Comparison with surgical findings

Author information +
History +
PDF

Abstract

The present study evaluated the application of three dimensional echocardigraphy (3DE) in the diagnosis of atrial septal defect (ASD) and the measurement of its size by 3DE and compared the size with surgical findings. Two-dimensional and real-time three dimensional echocardiography (RT3DE) was performed in 26 patients with atrial septal defect, and the echocardiographic data were compared with the surgical findings. Significant correlation was found between defect diameter by RT3DE and that measured during surgery (r=0.77, P<0.001). The defect area changed significantly during cardiac cycle. Percentage change in defect size during cardiac cycle ranged from 6%–70%. Our study showed that the size and morphology of atrial septal defect obtained with RT3DE correlate well with surgical findings. Therefore, RT3DE is a feasible and accurate non-invasive imaging tool for assessment of atrial septal size and dynamic changes.

Keywords

real-time three-dimensional echocardiography / atrial septal defect / two dimensional echocardiography

Cite this article

Download citation ▾
Saumu Tobbi Mweri, Youbin Deng, Peixuan Cheng, Hanhua Lin, Hongwei Wang, Ommari Baaliy Mkangara, Zhi Xia, Xiufen Hu, Xiaojun Bi, Yuhan Wu, Mustaafa Bapumiia, Weihui Shentu, Rong Liu, Yani Li, Meihua Zhu. Evaluation of atrial septal defect using real-time three-dimensional echocardiography: Comparison with surgical findings. Current Medical Science, 2009, 29(2): 257-259 DOI:10.1007/s11596-009-0225-y

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

HouckR.C., CookeJ.E., GillE.A.. Live 3D echocardiography a replacement for traditional 2D echocardiography?. AJR, 2006, 187: 1092-1106

[2]

ChengT.O., XieM.X., WangX.F., et al. . Real-time 3-Dimensional echocardiography assessing Atrial and ventricular septal defects: An echocardiographic-surgical correlative study. Am Heart J, 2004, 148: 617-619

[3]

BalestrinilL., FleishmanC., KislolL., et al. . Real-time-3dimensional echocardiography evaluation of congenital heart disease’s. Am Soc Echocadiogr, 2000, 13: 171-176

[4]

MarksG.R., FultonD.R., PandianD.G., et al. . Delineation of site, relative size and dynamic geometry of Atrial septal defect by real-time three dimensional echocardiography. J Am Coll Cardiol, 1995, 25: 482-490

[5]

AcarP., RouxD., DoulacY., et al. . Transthoracic three dimensional echocardiography prior to closure of Atrial septal defect in children. Cardiol Young, 2003, 13(1): 58-63

[6]

FrankeA., RulandsD., KuhlH.P., et al. . Changes of atrial septal defect area during the cardiac cycle: evaluation of dynamic transoesophegeal three dimensional echocardiography(Abstract). Euro Heart J, 1996, 17(suppl): 2317

[7]

ThonopolousB.D., LaskariC.V., TsaousG.S., et al. . Closure of Atrial septal defect with the Amplatzer occlusion device: preliminary results. J Am Coll Cardiol, 1998, 8531: 1110-1116

[8]

WangX.F., DengY.B., NandaN.C.. Live three dimension echocardiography, imaging principle and clinical application. J CEchocardiography, 2003, 20(7): 593-604

[9]

KannanB.R., FrancisE., SivakumarK., et al. . Transcatheter closure of very large (>25 mm) atrial septal defect using amplatzer septal occluder. Catheter Cardiovasc Interv, 2003, 59: 522-527

AI Summary AI Mindmap
PDF

113

Accesses

0

Citation

Detail

Sections
Recommended

AI思维导图

/