PDF
Abstract
The clinical application of 16-slice CT coronary angiography (CTCA) and the impact of plaques differently characterized on assessing coronary artery stenosis were evaluated. Thirty-eight patients with coronary artery disease diagnosed by conventional coronary angiography (CAG) underwent 16-slice CTCA (collimation: 16×0.75 mm; rotation time: 420 msec; kernel: 35f; effective current: 500 mAs; tube voltage: 120 kV). The interval between CTCA and CAG was within one month. CTCA was evaluated by consensus of two independent experienced radiologists unknowing CAG findings. Original images, maximum intensity projections and multiplanar reconstructions were used to assess coronary artery stenosis. For a determined plaque an attenuation value ⩾130 HU was considered as calcified, and <130 HU noncalcified. The plaques were then classified into significant calcification (extensive calcification), medium calcification (small isolated calcification) and noncalcification. The diagnostic accuracy of 16-slice CTCA findings as well as to detect ⩾50% stenoses caused by plaques was evaluated respectively regarding CAG as the standard of reference. In comparison with CAG findings, the sensitivity, specificity, positive and negative predictive value derived from CTCA for mild stenosis (<50%) were 72.7%, 38.5%, 50%, 62.5%, respectively; for moderate stenosis (50%–75%) 82.4%, 72.7%, 70%, 84.2%, resepctively; and for severe coronary stenosis (>75%) 85%, 90.5%, 81%, 92.7% respectively. With the increase of stenoses degree, the value of CTCA was greater. For the classification of the plaque calcification with ⩾50% stenosis CTCA attained the sensitivity, specificity, positive and negative predictive value for severe calcificatoin 73.3%, 22.2%, 61.1% and 33.3%, respectively; for moderate calcification 70%, 55.6%, 63.6% and 62.5%, respectively; for noncalcification 93.8%, 85.7%, 93.8% and 85.7% respectively. CTCA was restricted in assessing coronary artery stenosis in the presence of calcification, but CTCA value was much improved in assessing non-calcified stenosis. It was concluded that 16-slice CTCA could provide useful information about coronary artery stenosis, especially for severe stenosis (⩾50%) and non-calcified plaque. Since CTCA is a noninvasive technique, it may be useful in screening coronary artery disease.
Keywords
X-ray computed, tomography
/
coronary artery disease
/
angiocardiography
Cite this article
Download citation ▾
Yan Chen, Ping Han, Bo Liang, Huimin Liang, Ziqiao Lei, Zhiliang Tian, Gansheng Feng, Jie Xiao.
Comparative study on 16-slice CT coronary angiography vs conventional coronary angiography—A report of 38 cases.
Current Medical Science, 2008, 28(28): 110-113 DOI:10.1007/s11596-008-0128-3
| [1] |
NiemanK., OudkerkM., RensingB. J., et al.. Coronary angiography with multi-slice computed tomography. Lancet, 2001, 357(9256): 599-603
|
| [2] |
GieslerT., BaumU., RopersD., et al.. Noninvasive visualization of coronary arteries using contrastenhanced multidetector CT: influence of heart rate on image quality and stenosis detection. AJR, 2002, 179(4): 911-916
|
| [3] |
NiemanK., CademartiriF., LemosP. A., et al.. Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography. Circulation, 2002, 106(16): 2051-2054
|
| [4] |
AchenbachS., GieslerT., RopersD., et al.. Detection of coronary artery stenoses by contrast-enhanced, retrospectively electrocardiographically gated, multislice spiral computed tomography. Circulation, 2001, 103(21): 2535-2538
|
| [5] |
NiemanK., RensingB. J., van GeunsR. J. M., et al.. Non-invasive coronary angiography with multislice spiral CT: the impact of heart rate. Heart, 2002, 88(5): 470-474
|
| [6] |
FlohrT., OhnesorgeB.. Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart. J Comput Assist Tomogr, 2001, 25(6): 907-923
|
| [7] |
WangZ., YangZ., ZhuH., et al.. Detection of coronary artery stenoses using 16-slice spiral CT: comparison with quantitative coronary angiography. J Comput Tomogr, 2003, 3(1): 7-11
|
| [8] |
BeckerC. R., OhnesorgeB. M., SchoepfU. J., et al.. Current development of cardiac imaging with multidetector row CT. Eur J Radiol, 2000, 36(2): 97-103
|
| [9] |
SchroederS., KoppA. F., BaumbachA., et al.. Noninvasive detection and evaluation of atherosclerotic coronary plaque with multislice computed tomography. J Am Coll Cardiol, 2001, 37(5): 1430-1435
|