Assessment of atrial septum morphology by live three-dimensional echocardiography

Lingyun Fang , Mingxing Xie , Xinfang Wang , Zhaoxia Pu , Yali Yang , Lin He , Xiaoyan Zhou

Current Medical Science ›› 2007, Vol. 27 ›› Issue (18) : 687 -690.

PDF
Current Medical Science ›› 2007, Vol. 27 ›› Issue (18) : 687 -690. DOI: 10.1007/s11596-007-0618-8
Article

Assessment of atrial septum morphology by live three-dimensional echocardiography

Author information +
History +
PDF

Abstract

To evaluate the morphology of atrial septum by the live three-dimensional echocardiography (L3DE) and its value of clinical application, L3DE was performed in 62 subjects to observe the morphological characteristics and dynamic change of the overall anatomic structure of atrial septum. The study examined 49 patients with atrial septal defect (ASD), including 3 patients with atrial septal aneursym, and 10 healthy subjects. ASD in the 35 patients was surgically confirmed. The maximal diameters of ASD were measured and the percentages of area change were calculated. The parameters derived from L3DE were compared with intraoperative measurements. The results showed that L3DE could directly and clearly display the morphological features of overall anatomic structure of normal atrial septum, repaired and artificially-occluded atrial septum, atrial septal aneurysm. The defect area in ASD patients changed significantly during cardiac cycle, which reached a maximum at end-systole and a minimum at end-diastole, with a mean change percentage of 46.6%, ranging from 14.8% to 73.4%. The sizes obtained from L3DE bore an excellent correlation with intraoperative findings (r=0.90). It is concluded that L3DE can clearly display the overall morphological features and dynamic change of atrial septum and measure the size of ASD area accurately, which is important in the decision to choose therapeutic protocols.

Keywords

live three-dimensional echocardiography / atrial septal defects / atrial septum

Cite this article

Download citation ▾
Lingyun Fang, Mingxing Xie, Xinfang Wang, Zhaoxia Pu, Yali Yang, Lin He, Xiaoyan Zhou. Assessment of atrial septum morphology by live three-dimensional echocardiography. Current Medical Science, 2007, 27(18): 687-690 DOI:10.1007/s11596-007-0618-8

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

PepiM., TamboriniG., PontoneG. L., et al.. Initial experience with a new on-line transthoracic three-dimensional technique: assessment of feasibility and of diagnostic potential. Ital Heart J, 2003, 4(8): 544-550

[2]

FaletraF., ScarpiniS., MoreoA., et al.. Color Doppler echocardiographic assessment of atrial septal defect size: correlation with surgical measurements. J Am Soc Echocardiogr, 1991, 4(5): 429-434

[3]

TakumaS., OtaT., MuroT.. Assessment of left ventricular function by real-time three-dimensional echocardiography compared with conventional noninvasive methods. J Am Soc Echocardiogr, 2001, 14(4): 275-284

[4]

Van den BoschA. E., Robbers-VisserD., KrenningB. J., et al.. Real-time transthoracic three-dimensional echocardiographic assessment of left ventricular volume and ejection fraction in congenital heart disease. J Am Soc Echocardiogr, 2006, 19(1): 1-6

[5]

CorsiC., LangR. M., VeronesiF., et al.. Volumetric quantification of global and regional left ventricular function from real-time three-dimensional echocardiographic images. Circulation, 2005, 112(8): 1161-1170

[6]

XieM. X., WangX. F., ChengT. O., et al.. Comparison of accuracy of mitral valve area in mitral stenosis by real-time, three-dimensional echocardiography versus two-dimensional echocardiography versus Doppler pressure half-time. Am J Cardiol, 2005, 95(12): 1496-1499

[7]

WangX. F., DengY. B., NandaN. C., et al.. Live three-dimensional echocardiography: imaging principles and clinical application. Echocardiography, 2003, 20(7): 593-604

[8]

Dall’AgataA., McGhieJ., TaamsM. A., et al.. Secundum atrial septal defect is a dynamic three dimensional entity. Am Heart J, 1999, 137(6): 1075-1081

[9]

SadlerT. W.. Langman’s Medical Embryology, 1995, Baltimore, Williams & Wilkins: 191-197

[10]

AcarP., RouxD., DulacY., et al.. Transthoracic three-dimensional echocardiography prior to closure of atrial septal defects in children. Cardiol Young, 2003, 13(1): 58-63

[11]

JanS. L., HwangB., LeeP. C., et al.. Intracardiac ultrasound assessment of atrial septal defect: comparison with transthoracic echocardiographic, angiocardiographic, and balloon-sizing measurements. Cardiovasc Intervent Radiol, 2001, 24(2): 84-89

[12]

EwertP., BergerF., DaehnertI., et al.. Transcatheter closure of atrial septal defects without fluoroscopy: feasibility of a new method. Circulation, 2000, 101(8): 847-849

[13]

Abdel-MassihT., DulacY., TaktakA., et al.. Assessment of atrial septal defect size with 3D-transesophageal echocardiography: comparison with balloon method. Echocardiography, 2005, 22(2): 121-127

AI Summary AI Mindmap
PDF

109

Accesses

0

Citation

Detail

Sections
Recommended

AI思维导图

/