Abstract

This study examined the cytotoxicity of a new implant material modified by microarc oxidation technique. Cells on different surfaces of the implant were evaluated 2, 4 and 6 days after treatment. The results showed that cell attachment, cell morphology, and cell proliferation were influenced by the different surface treatments, and a significant increase in the osteoblast cell activity was observed on the porous MAO-Ti coating. Our results suggest that the porous MAO-Ti surface has a better biocompatibility and electrochemical performance than pure titanium surface.

Keywords

implant material / titanium / cytotoxicity / MTT

Cite this article

Download citation ▾
Cheng Yang, Li’e Meng, Yuan Tian, Tao Huang, Yuanying Li. Cytotoxicity study of a novel implant material modified by microarc oxidation. Current Medical Science, 2006, 26(6): 720-722 DOI:10.1007/s11596-006-0625-1

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

MandlS., SaderR., KrauseD., et al.. Investigation on plasma immersion ion implantation treated medical implants. Biomol Eng, 2002, 19: 129-132

[2]

KatzJ. L.. RatnerB. D., HoffmanA. S., SchoenF. J.. Orthopedic Applications. Biomaterials Science. An Introduction to Materials in medicine, 1996, Orlando, Academic: 335-346

[3]

MosmannT.. T-cell and mast cell lines respond to B-cell stimulatory factor. J Immunol Methods, 1986, 83(15): 5654-5658

[4]

CiapettiG., CenniE., PratelliL., et al.. In vitro evaluation of cell/biomaterial interaction by MTT assay Biomaterials, 1993, 14(5): 359-364

[5]

ZhaoX. C., LanX. Z., ShangZ. Y., et al.. Cytotoxicity of two kinds of cssting alloys of dental precious metals. rare metal matera and Eng(Chinese), 2003, 32(10): 822-824

[6]

X. Y., KappertH. F.. The novel method for evaluation cytotoxicity of dental materials (MTT test). Zhonghua Kouqiang Yixue Zazhi (Chinese), 1995, 30(6): 377-379

[7]

YangG. L., LuX. Y., BaiY. Z., et al.. The effects of current density on the phase composition and microarc properties of microarc oxidation coating. J Alloy Comp, 2002, 345: 196-200

[8]

LukiyanchukI. V., RudnevV. S., KuryavyiV. G., et al.. Surface morphology, composition and thermal behavior of tungsten-containing anodic spark coatings on aluminium alloy. Thin Solid Films, 2004, 446: 54-60