Abstract

To compare and evaluate two methodologies, entire-sampling and micro-sampling for the harvesting of vitreous humor, the vitreous humor of rabbits were sampled with the two methods respectively, and the concentrations of calcium, chlorine, potassium, sodium and phosphorus of the were measured. The results showed that the differences in the variance coefficient and two-eye concentrations of micro-sampled specimens were less than those of the entire-sampled specimens. In the micro-sampling group, the concentrations of repeated micro-sampling showed no differences among different groups (P>0.05) and the intra-ocular fluid dynamics did not have significant influence on post-mortem sampling. The sampling technique may affect the concentrations of specimen collected. Our study suggests that micro-sampling is less influenced by the human factor and is reliable, reproducible, and more suitable for forensic investigation.

Keywords

vitreous humor / sampling techniques / comparative study

Cite this article

Download citation ▾
Lan Wang, Weiguang Zhou, Liang Ren, Qian Liu, Liang Liu. Comparative study of two vitreous humor sampling methods in rabbits. Current Medical Science, 2006, 26(4): 475-477 DOI:10.1007/s11596-006-0426-6

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

CoeJ. I.. Postmortem chemistry update. Emphasis on forensic application. Am J Forensic Med Pathol, 1993, 14(2): 91-117

[2]

BalasooriyaB. A., St HillC. A., WilliamsA. R.. The biochemistry of vitreous humour: A comparative study of the potassium, sodium and urate concentrations in the eyes at identical time intervals after death. Forensic Sci Int, 1984, 26(2): 85-91

[3]

MadeaB., HenssgeC., HonigW., et al.. References for determining the time of death by potassium in vitreous humor. Forensic Sci Int, 1989, 40(3): 231-243

[4]

PounderD. J., CarsonD. O., JohnstonK., et al.. Electrolyte concentration differences between left and right vitreous humor samples. J Forensic Sci, 1998, 43(3): 604-607

[5]

Bocaz-BeneventiG., TagliaroF., BortolottiF., et al.. Capillary zone electrophoresis and artificial neural networks for estimation of the post-mortem interval (PMI) using electrolytes measurements in human vitreous humour. Int J Legal Med, 2002, 116(1): 5-11

[6]

TagliaroF., BortolottiF., ManettoG., et al.. Potassium concentration differences in the vitreous humour from the two eyes revisited by microanalysis with capillary electrophoresis. J Chromatogr A, 2001, 924(1–2): 493-498

[7]

HenssgeC., KnightB., KrompecherT., et al.. The estimation of the time since death in the early postmortem period, 1995, London, Edward Arnold: 112-113

AI Summary AI Mindmap
PDF

107

Accesses

0

Citation

Detail

Sections
Recommended

AI思维导图

/