Echocardiography in the detection of atrial septal defect

Wang Xinfang , Chen Hanrong

Current Medical Science ›› 1982, Vol. 2 ›› Issue (2) : 120 -127.

PDF
Current Medical Science ›› 1982, Vol. 2 ›› Issue (2) : 120 -127. DOI: 10.1007/BF02908877
Article

Echocardiography in the detection of atrial septal defect

Author information +
History +
PDF

Abstract

The results of investigation by M-mode, two-dimensional and contrast echocardiography in 41 patients with ASD are reported. The differences in the heart shape, the dimensional ratio between the right and left ventricles, and the direction of the interventricular septal motion of the patients with ostium primum defect, ostium secundum defect and trilogy of Fallot are described. The characteristics of left-to-right, bi-directional and right-to-left shunts at the atrial level in contrast echocardiography and their relation to hemodynamic changes are also mentioned. The clinical value of echocardiography in detection of ASD and problems relating to its improvement are discussed.

Keywords

contrast echocardiography / atrial septal defect / shunt

Cite this article

Download citation ▾
Wang Xinfang, Chen Hanrong. Echocardiography in the detection of atrial septal defect. Current Medical Science, 1982, 2(2): 120-127 DOI:10.1007/BF02908877

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

GramiakR, et al. . Ultrasound cardiography: Contrast studies in anatomy and function. Radiology, 1969, 92: 939-939

[2]

DillonJC, et al. . Cross-sectional echocardiographic examination of the interatrial septum. Circulation, 1977, 55: 115-115

[3]

KronikG, et al. . Contrast M-mode echocardiography in diagnosis of atrial septal defect in acyanotic patients. Circulation, 1979, 59: 372-372

[4]

FrakerTD, et al. . Detection and exclusion of interatrial shunts by two-dimensional echocardiography and peripheral venous injection. Circulation, 1979, 59: 379-379

[5]

WeymanAE, et al. . Negative contrast echocardiography: A new method for detecting left-to-right shunts. Circulation, 1979, 59: 498-498

[6]

LangeLW, et al. . Subxiphoid cross-sectional echocardiography in infants and children with congenital heart disease. Circulation, 1979, 59: 513-513

[7]

TajikAJ, et al. . Echocardiographic patterns of right ventricular diastolic volume overload in children. Circulation, 1972, 46: 36-36

[8]

WangXF, et al. . Contrast echocardiography with hydrogen peroxide, I. Clinical application. Chin Med J., 1979, 92: 693-693

[9]

(6): 44, 1978

[10]

1 (1): 2, 1979.

[11]

Val-salva 3(1): 12, 1981

[12]

2(3): 183, 1980

AI Summary AI Mindmap
PDF

94

Accesses

0

Citation

Detail

Sections
Recommended

AI思维导图

/