Development and clinical application of an quantitative head-band formed ocular compressor

Xiao Qing , Xiao Shiyi , Hu Yanhua , Wang Zhi

Current Medical Science ›› 2002, Vol. 22 ›› Issue (1) : 66 -68.

PDF
Current Medical Science ›› 2002, Vol. 22 ›› Issue (1) : 66 -68. DOI: 10.1007/BF02904793
Article

Development and clinical application of an quantitative head-band formed ocular compressor

Author information +
History +
PDF

Abstract

In order to investigate the efficiency of a new quantitative head-band formed ocular compressor to reduce intraocular pressure (IOP), ocular compression by this new reducer with 40 mmHg for 10 min was performed on 87 cataractous eyes of 78 cases. The changes of IOP (87 eyes) and anterior chamber depth (ACD) were observed. There was a significant decrease of IOP and increase of ACD within 30 min after decompression (P<0.001). The mean decrease of IOP was 5.62±2.41 mmHg and the mean increase of ACD was 0.18±0.09 mm within 5 min after decompression. The IOP 5 min after decompression had no significant difference with that 10 min after decompression (P >0.05). IOP below 10 mmHg could last for about 15 min. This apparatus had been successfully applied to 80 eyes for extracapsular cataract extraction. It was suggested that this device had the advantages of safety, accurate quantification, reliable effect, casually adjusting pressure according to various demands and time-saving.

Keywords

cataract / compressor / intraocular pressure

Cite this article

Download citation ▾
Xiao Qing, Xiao Shiyi, Hu Yanhua, Wang Zhi. Development and clinical application of an quantitative head-band formed ocular compressor. Current Medical Science, 2002, 22(1): 66-68 DOI:10.1007/BF02904793

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

KirschR E, SteinmanW, SpiveyB E, et al. . Digital pressure, an important safeguard in cataract surgery. Arch Ophthalmol, 1955, 54: 697-697

[2]

JaffeN S. Cataract surgery and its complications, 1981ed 3St Louis, Mosby: 257-257

[3]

JayW M, CarterH, WilliamsB, et al. . Effect of applying the Honan's intraocular pressure reducer before cataract surgery. Am J Ophthalmol, 1985, 100: 523-523

[4]

DavidsonB, KratzR P, MazzoccoT R, et al. . An evaluation of the Honan's intraocular pressure reducer. Am J Intraocular Implant Soc, 1979, 5: 237-237

[5]

BlumenthalM, GitterK A, BestM, et al. . Fluorescein angiography during induced ocular hypertension in man. Am J Ophthalmol, 1970, 69: 39-39

[6]

HildrethH. Digital ocular compression proceeding cataract surgery. Am J Ophthalmol, 1961, 51: 1237-1237