Abstract

During last 16 years we have successfully developed the computer-assisted vectorcardiogram analysis systems: model TJ-I. TJ-I, and TJ-I, but some technical problems remained unresolved, such as the recognition accuracy for vectorcardiograms, measurement of the parameters of complicated QRS waves, the ratio of T loop length to width, and the area of spatial vectors etc. A new system, model TJ-IV was designed to resolve these technical problems. The system was equipped with a 586 computer with a CPU of 120 MHz. Special new low-noise amplifier was employed and C language was used for programming. Three graph recognition techniques were used to enhance the accuracy of VCG recognition. 32 orthogonal electrocardiograms and vectorcardiograms were displayed and printed, and 566 parameters of vectorcardiograms were calculated. Our results with 150 cases showed that the system had high accuracy of graph recognition, and parameter calculation and the results were essentially consistent with those of manipulative methods. We were led to concluded when compared with TJ-I system, the new version has higher accuracy of processing and measurement for vectorcardiograms, is able to process more vectorcardiographic parameters, with higher processing speed.

Keywords

vectorcardiogram / orthogonal electrocardiogram / computer-assisted diagnosis

Cite this article

Download citation ▾
Guo Xiaomei, Jue Xianghong, Ruan Yanfei, Wang Zhaochun. Model TJ-IV computer-assisted vectorcardiogram analysis system. Current Medical Science, 2001, 21(1): 21-22 DOI:10.1007/BF02888027

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

1987, 67:483

[2]

TJ-I 1995, 6(1): 8

[3]

AstromM, Carro SantosE. Vectorcardiographic loop alignment and the measurement of morphologic beat-to-beat variability in noisy signals. IEEE Trans Biomed Eng, 2000, 47(4): 497-497

[4]

Frank ECG VCG,1997,7: 4

[5]

1989, 28(1): 10

[6]

JensenJ, ErikssonS V, LindvallB, et al.. On-line vectorcardiography during elective coronary angioplasty indicates procedure-related myocardial infarction. Coron Artery Dis, 2000, 11(2): 161-161

[7]

WatanabeY, WangJ, KondoT, et al.. Vectorcardiographic evaluation of myocardial infarct size: departure parameters are superior to conventional spatial parameters. Jpn Circ J, 1998, 62(7): 473-473

[8]

SawadaK, HiraiM, HayashiH, et al.. Spatial ventricular gradient in patients with Wolff-Parkinson-White syndrome in comparison with normal subjects: vectorcardiographic evidence for significant repolarization changes due to preexcitation. Intern Med, 1995, 34(8): 738-738

[9]

BernadicM, HatalaR, KaltenbrunnerW, et al.. Location of atrial and ventricular insertions of accessory atrioventricular pathways using surface ECG mapping and its importance in catheter ablation therapy. Bratisl Lek Listy, 1995, 96(4): 210-210

[10]

Frank,1989, 17(2): 143

AI Summary AI Mindmap
PDF

87

Accesses

0

Citation

Detail

Sections
Recommended

AI思维导图

/