The value of perioperative echocardiography in percutaneous balloon mitral valvuloplasty

Lu Qing , Wang Xinfang , Cao Linsheng , Li Zhi’an , Yang Ya , Liu Li

Current Medical Science ›› 1996, Vol. 16 ›› Issue (2) : 91 -95.

PDF
Current Medical Science ›› 1996, Vol. 16 ›› Issue (2) : 91 -95. DOI: 10.1007/BF02887965
Article

The value of perioperative echocardiography in percutaneous balloon mitral valvuloplasty

Author information +
History +
PDF

Abstract

In order to investigate the value of perioperative echocardiography in percutaneous balloon mitral valvuloplasty (PBMV), two-dimensional echocardiography (2-DE), Doppler echocardiography and color Doppler flow imaging (CDFI) were employed prior to PBMV in 52 patients and during or after PBMV in 15 patients. The results showed that TTE and TEE were helpful in the selection of candidates for 2-DE transseptal and balloon dilation procedures. Continuous monitoring of 2-DE, Doppler echocardiography and CDFI during PBMV could make this procedure safer and more effective, reduce X-ray exposure and avoid complications. Echocardiography was useful in fluoroscopy and could be used for evaluation of the effects of operation.

Keywords

echocardiography / percutaneous balloon mitral valvuloplasty / perioperation

Cite this article

Download citation ▾
Lu Qing, Wang Xinfang, Cao Linsheng, Li Zhi’an, Yang Ya, Liu Li. The value of perioperative echocardiography in percutaneous balloon mitral valvuloplasty. Current Medical Science, 1996, 16(2): 91-95 DOI:10.1007/BF02887965

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

InoueK, NakamuraT, KitamuraF, et al.. Clinical application of transvenous mitral commissurotomy by a new balloon catheter. J Thorac Cardiovasc Surg, 1984, 87: 394-394

[2]

1991. 76∼89

[3]

ReidC L, RahimtoolaS H. The role of echocardiography/Doppler in catheter balloon treatment of adults with aortic and mitral stenosis. Circulation, 1991, 84(Suppl I): I-240

[4]

KronzonI, TunickP A, ClassmanB, et al.. Transesophageal echocardiography to detect atrial clots in candidates for percutaneous balloon mitral valvuloplasty. J Am Coll Cardiol, 1990, 16: 1320-1320

[5]

ChanK L, MarquisJ F, AscahC, et al.. Role of transesophageal echocardiography in percutaneous balloon mitral valvuloplasty. Echocardiography, 1990, 7: 115-115

[6]

RamondoA, ChirilloF, DanM, et al.. Value and limitations of transesophageal echocardiographic monitoring during percutaneous balloon mitral valvotomy. Int J Cardiol, 1991, 31: 223-223

[7]

LandzbergJ S, FranklinJ O, LangbergO J, et al.. The transponder system: A new method of precise catheter placement in the right atrium under echocardiographic guidance. J Am Coll Cardiol, 1988, 12: 753-753

AI Summary AI Mindmap
PDF

79

Accesses

0

Citation

Detail

Sections
Recommended

AI思维导图

/