Clinical application of surface mode on three-dimensional ultrasonography: A preliminary study

Xu Huixiong , Zhang Qingping , Zhou Yuqing , Le Guirong , Wang Yuanfang

Current Medical Science ›› 2000, Vol. 20 ›› Issue (2) : 159 -162.

PDF
Current Medical Science ›› 2000, Vol. 20 ›› Issue (2) : 159 -162. DOI: 10.1007/BF02887061
Article

Clinical application of surface mode on three-dimensional ultrasonography: A preliminary study

Author information +
History +
PDF

Abstract

To investigate the methodology and evaluate the clinical value of surface mode on three-dimensional ultrasonography (3DUS) in static anatomical structures, 62 patients with various diseases were studied. The equipment used here was Voluson 530D 3DUS imaging system and 3D volume transducer with frequency being 3.0—5.0 MHz. The 3DUS rendering method was surface mode. The results showed that: 1) Surface mode of 3DUS could demonstrate clearly the anatomical characteristics of the region-of-interest (ROD and the inner wall of lesions or organs that contained fluid. The anatomic details, such as location, size, shape, and number of the ROI, could be visualized intuitively; 2) The outer anatomic features (e.g. contour, edge, configuration, etc.) of some organs or lesions surrounded by fluid could be displayed clearly. It could be concluded that surface mode on 3DUS could provide more diagnostic information than two-dimensional ultrasonography (2DUS) in some cases and could served as a beneficial supplement to 2DUS in clinical practice.

Keywords

three-dimensional ultrasonography / surface mode / volume transducer

Cite this article

Download citation ▾
Xu Huixiong, Zhang Qingping, Zhou Yuqing, Le Guirong, Wang Yuanfang. Clinical application of surface mode on three-dimensional ultrasonography: A preliminary study. Current Medical Science, 2000, 20(2): 159-162 DOI:10.1007/BF02887061

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

RankinR N, FensterA, DowneyD B, et al.. Three-dimensional sonographic reconstruction: techniques and diagnostic applications. AJR, 1993, 161: 695-695

[2]

DowneyD B, FensterA. Vascular imaging with a three-dimensional power Doppler system. AJR, 1995, 165: 665-665

[3]

HamperU M, TrapanottoV, ShethS, et al.. Three-dimensional US: preliminary clinical experience. Radiology, 1994, 191: 397-397

[4]

1998,7(1):3

[5]

1999,8(2):8

[6]

1999,15(6):412

[7]

XuH X, ZhangQ P, ZhouY Q. The clinical application of three-dimensional sonography in hepatobiliary diseases. J CAUME, 1999, 5(2): 61-61

[8]

NelsonT R, PretoriusD H. Three-dimensional ultra-sound imaging. Ultrasound Med Biol, 1998, 24(9): 1243-1243

AI Summary AI Mindmap
PDF

106

Accesses

0

Citation

Detail

Sections
Recommended

AI思维导图

/