Determination of most appropriate Nyquist velocity for applying hemispherical flow convergence equation to calculate flow rate using the transorifice pressure gradient: Digital computer analysis of doppler color flow convergence region

Deng You-bin , Wang Xin-fang , Wang Jia-en , Li Zhi-an , Takahiro Shiota , David J. Sahn

Current Medical Science ›› 1993, Vol. 13 ›› Issue (4) : 143 -150.

PDF
Current Medical Science ›› 1993, Vol. 13 ›› Issue (4) : 143 -150. DOI: 10.1007/BF02886505
Article

Determination of most appropriate Nyquist velocity for applying hemispherical flow convergence equation to calculate flow rate using the transorifice pressure gradient: Digital computer analysis of doppler color flow convergence region

Author information +
History +
PDF

Abstract

Nyquist velocity and transorifice pressure gradient dramatically influence color aliasing shape and accuracy of simple hemispherical flow convergence equation for calculation of flow rate. The present in vitro study was performed to determine whether the value of Nyquist velocity, at which the shape of proximal isovelocity surface is best fit for a given shape assumption in different orifice size, and the flow rate may be a determinable and orifice size independent function of clinically measurable peak velocity or transorifice pressure gradient. Steady flow was driven through circular discrete orifices with diameter of 3. 8 mm, 5.5 mm and 10 mm and flow rate ranging from 2.88 L/min to 8.2 8 L/min. For every flow rate, Doppler color encoded M-mode images through the center of flow convergence region were transferred into the microcomputer in their original digital format. The continuous wave Doppler traces of maximal velocity through the orifice were performed for the calculation of pressure gradient. Direct numerical spatial velocity measure using color pixel intensity was obtained from the transferred color encoded M-mode images with computer software. The shape of isovelocity surface was determined by the ratio of calculated flow rate with hemispherical flow convergence equation to the actual flow rate. Both the flow rate and orifice size influence the position of the velocity profile curve. The shape of isovelocity surface is not constant and changes with the velocities used for the calculation of flow rates for a given flow rate and orifice size or pressure gradient and also changes with the flow rate or transorifice pressure gradients for a constant Nyquist velocity and orifice size. It was found that for a given ratio of calculated flow rate to actual flow rate (0. 7 and 1) the velocities used for the calculation of flow rate with hemispherical flow convergence equation were correlated well with the pressure gradient for a given orifice size and the differences in velocities among different orifice sizes adjusted for the covariance pressure gradients were not statistically significant (P = 0.794 for ratio = 0.7 andP = 0.81 for ratio = l). Our present study provides an orifice size independent quantitative method with which to select the most suitable Nyquist velocity for applying simple hemispherical flow convergence equation according to clinically measurable pressure gradients ranging from 5.32 kPa to 26.60 kPa, and offers a correcting factor for the hemispherical flow convergence equation when pressure gradient is less than 5.32 kPa.

Keywords

color Doppler echocardiography / flow convergence / pressure gradient / regurgitant flow rate

Cite this article

Download citation ▾
Deng You-bin, Wang Xin-fang, Wang Jia-en, Li Zhi-an, Takahiro Shiota, David J. Sahn. Determination of most appropriate Nyquist velocity for applying hemispherical flow convergence equation to calculate flow rate using the transorifice pressure gradient: Digital computer analysis of doppler color flow convergence region. Current Medical Science, 1993, 13(4): 143-150 DOI:10.1007/BF02886505

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

ShandasR, GharibM, LiepmannD, et al. . Experimental sutdies to define the geometry of the flow convergence region. Laser Doppler particle tracking and color Doppler imaging. Echocardiography, 1992, 943-43

[2]

RecusaniF, BargiggiaG S, YoganathanA P, et al. . A new method for quantification of regurgitant flow rate using color Doppler flow imaging of the flow convergence region proximal to a discrete orifice: an in vitro study. Circulation, 1991, 83594-594

[3]

SahnD J, SimpsonJ A, MurilloA, et al. . Observation of acceleration proximal to restrictive orifices in congenital heart disease: Important clues for the interpretation of Doppler color flow maps (abstract). Circulation, 1988, 789(suppl I): 649-649

[4]

UtsunomiyaT, OgawaT, DoshiR, et al. . Doppler color flow“ proximal isovelocity surface area” method for estimating volume flow rate: effects of orifice shape and machine factors. J Am Coll Cardiol, 1991, 171103-1103

[5]

ShandasR, BeltJ P, CaliG, et al. . Comparison of analog and digital methods of transferring color Doppler image data for off-line analysis (abstract). J Am Coll Cardiol, 1990, 1588A-88A

[6]

SimpsonI A, SneddonJ F, SmithG, et al. . Quantitation of spatial velocity characteristics in hypertrophic cardiomyopathy: On-line digital analysis of color Doppler flow map imagings. Circulation, 1991, 84(suppl I): 636-636

[7]

HatleL, AngelsenB A, TromsdalA. Noninvasive assessment of aortic stenosis by Doppler ultrasound. Br Heart J, 1980, 43284-284

[8]

ShiotaT, Valdes-CruzL M, SahnD J, et al. . Estimation of cardiac output and mitral orifice area using new proximal flow convergence method: Validation in animal model of chronic mitral stenosis (abstract). J Am Coll Cardiol, 1992, 19(3): 358A-358A

[9]

RogriguezL, MonterrosoV, MuellerL, et al. . Validation of a new method for valve area calculation using the proximal isovelocity surface area in patients with mitral stenosis (abstract). J Am Coll Cardiol, 1990, 15(suppl A): 109A-109A

[10]

BargiggiaG S.Tronconi L.Sahn D J, et al. . A new method for quantitation of mitral regurgitation based on color Doppler flow imaging of flow convergence proximal to regurgitant orifice. Circulation, 1991, 841481-1481

[11]

ChenC, KoschykD, MehlC, et al. . Comparison of quantifying mitral regurgitation using color Doppler proximal isovelocity surface area and angiography (abstract). Circulation, 1991, 84(suppl I): 637-637

[12]

BargiggiaG S, TronconiL, RasaroA, et al. . Color Doppler diagnosis of mechanical prosthetic mitral regurgitation:: usefulness of the flow convergence region proximal to the regurgitant orifice. Am Heart J, 1990, 1201137-1137

[13]

MoisesV A. Maciel B C, HornbergerL K, et al. . A new nethod for noninvasive estimation of ventricular septal defect shunt flow by Doppler color flow mapping. imaging of the laminar flow convergence region on the left septal surface. J Am Coll Cardiol, 1991, 18824-824

[14]

SimpsonI A, SahnD J, Valdes-CruzLM, et al. . Color Doppler flow mapping in patients with coarctation of the aorta, new observations and improved evaluation with color flow diameter and proximal acceleration as predictors of severity. Circulation, 1988, 77736-736

AI Summary AI Mindmap
PDF

75

Accesses

0

Citation

Detail

Sections
Recommended

AI思维导图

/