Non-invasive assessment of coronary flow velocity reserve: A new method using transthoracic Doppler echocardiography

Yang Ya , Thomas Bartel , Holger Eggebrecht , Loredana Latina , Clemems von Birgelen , Guido Caspari , Wang Xinfang , Raimund Erbel

Current Medical Science ›› 2002, Vol. 22 ›› Issue (23) : 158 -163.

PDF
Current Medical Science ›› 2002, Vol. 22 ›› Issue (23) : 158 -163. DOI: 10.1007/BF02857683
Article

Non-invasive assessment of coronary flow velocity reserve: A new method using transthoracic Doppler echocardiography

Author information +
History +
PDF

Abstract

Transthoracic Doppler echocardiography (TTDE) allows noninvasive flow measurement in the distal left anterior descending artery (LAD). The feasibility of detecting coronary flow by contrast-enhanced TTDE with second harmonic technique was assessed, the coronary flow velocity reserve (CFVR) was evaluated in comparison to intracoronary Doppler flow (ICD) analysis and the CFVR after PTCA in LAD was investigated. In 77 (96%) of 80 patients, CFVR was successfully determined with intravenous adenosine infusion. Doppler signal quality was evaluated in the first 46 patients by use of intravenous Levovist infusion and second harmonic technique. The Doppler flow was not visible in 1 patient only. CFVR determined from TTDE (2.77±0.65) was correlated closely with those from ICD (2.88±0.78) measurements (y=0.73x+0.67,r=0.87,P<0.001). In conclusion, TTDE is a feasible method and provides reliable data on CFVR which can be used for followup after PTCA.

Keywords

coronary flow velocity reserve / Doppler echocardiography / intracoronary Doppler

Cite this article

Download citation ▾
Yang Ya, Thomas Bartel, Holger Eggebrecht, Loredana Latina, Clemems von Birgelen, Guido Caspari, Wang Xinfang, Raimund Erbel. Non-invasive assessment of coronary flow velocity reserve: A new method using transthoracic Doppler echocardiography. Current Medical Science, 2002, 22(23): 158-163 DOI:10.1007/BF02857683

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

KernM J, DeligonulU, TatineniS, et al. . Intravenous adenosine: continuous infusion and low dose bolus administration for determination of coronary vasodilator reserve in patients with and without coronary artery disease. J Am Coll Cardiol, 1991, 18718-718

[2]

BaumgartD, HaudeM, GoergeG, et al. . Improved assessment of coronary stenosis severity using the relative flow velocity reserve. Circulation, 1998, 9840-40

[3]

WienekeH, HaudeM, GeJ, et al. . Corrected coronary flow velocity reserve: a new concept for assessing coronary perfusion. J Am Coll Cardiol, 2000, 351713-1713

[4]

ErbelR, GeJ, BockischA, et al. . Value of intracoronary ultrasound and Doppler in the differentiation of angiographically normal coronary arteries: a prospective study in patients with angina pectoris. Eur Heart J, 1996, 17880-880

[5]

ErbelR. Transesophageal echocardiography: new window to coronary arteries and coronary blood flow. Circulation, 1991, 83339-339

[6]

CaiatiC, MontaldoC, ZeddaN, et al. . New noninvasive method for coronary flow reserve assessment. Contrast-enhanced transthoracic second harmonic echo Doppler. Circulation, 1999, 99771-771

[7]

HozumiT, YoshidaK, AkasakaT, et al. . Noninvasive assessment of coronary flow velocity and coronary flow velocity reserve in the left anterior descending coronary artery by Doppler echocardiography. Comparison with invasive technique. J Am Coll Cardiol, 1998, 321251-1251

[8]

IlicetoA, CaiatiC, AragonaP, et al. . Improved Doppler signal intensity in coronary arteries after intravenous peripheral injection of a lung-crossing contrast agent (SHU 508A). J Am Coll Cardiol, 1994, 23184-184

[9]

Di MarioC, MeneveauN, GilR, et al. . Maximal blood flow velocity in severe coronary stenosis measurement with a Doppler guide wire: limitations for the application of the continuity equation in the assessment of stenosis severity. Am J Cardiol, 1993, 7154D-54D

[10]

CaiatiC, ZeddaN, MontaldoC, et al. . Contrast-enhanced transthoracic second harmonic echo Doppler with adenosine. A noninvasive, rapid and effective method for coronary flow reserve assessment. J Am Coll Cardiol, 1999, 34122-122

[11]

BartelT, MüllerS, BaumgartD, et al. . Improved high-frequency transthoracic flow velocity measurement in the left anterior descending coronary artery after intravenous peripheral injection of Levovist. J Am Soc Echocardiogr, 1999, 12252-252

[12]

DoucetteJ W, CorlP D, PayneH M, et al. . Validation of a Doppler guide wire for intravascular measurements of coronary artery flow velocity. Circulation, 1992, 851899-1899

[13]

WilsonR F, WycheK, ChristensenB V, et al. . Effects of adenosine on human coronary arterial circulation. Circulation, 1990, 821595-1595

[14]

RossenJ D, QuillenJ E, LopezA G, et al. . Comparison of coronary vasodilation with intravenous dipyridamole and adenosine. J Am Coll Cardiol, 1991, 18485-485

[15]

LabovitzA J, OfiliE O, KernM J. DagiantiA, FeigenbaumH. Evaluation of coronary flow by intracoronary Doppler flow wire. Echocardiography, 1993, Shannon, Ireland, Elsevier Science Ireland: 27-33

[16]

HasdaiD, HolmesD R, HiganoS T, et al. . Effect of basal epicardial tone on endothelium-independent coronary flow reserve measurement. Cathet Cadiovasc Diagn, 1998, 44392-392

AI Summary AI Mindmap
PDF

96

Accesses

0

Citation

Detail

Sections
Recommended

AI思维导图

/