Evaluation of right ventricular volume and systolic function by realtime three-dimensional echocardiography

Wang Jing , Wang Xinfang , Xie Mingxing , Yang ya , LV Qing , Yang Ying , Wang Liangyu

Current Medical Science ›› 2005, Vol. 25 ›› Issue (28) : 94 -96.

PDF
Current Medical Science ›› 2005, Vol. 25 ›› Issue (28) : 94 -96. DOI: 10.1007/BF02831398
Article

Evaluation of right ventricular volume and systolic function by realtime three-dimensional echocardiography

Author information +
History +
PDF

Abstract

The optimal plane for measurement of the right ventricular (RV) volumes by real-time three-dimensional echocardiography (RT3DE) was determined and the feasibility and accuracy of RT3DE in studying RV systolic function was assessed. RV “Full volume” images were acquired by RT3DE in 22 healthy subjects. RV end-diastolic volumes (RVEDV) and end-systolic volumes (RVESV) were outlined using apical biplane, 4-plane, 8-plane, 16-plane offline separately. RVSV and RVEF were calculated. Meanwhile tricuspid annual systolic excursion (TASE) was measured by M-mode echo. LVSV was outlined by 2-D echo according to the biplane Simpson's rule. The results showed: (1) There was a good correlation between RVSV measured from series planes and LVSV from 2-D echo (r=0. 73;r=0. 69;r=0. 63;r=0. 66,P<0. 25–0. 0025); (2) There were significant differences between RVEDV in biplane and those in 4−, 8−, 16-plane (P<0.001). There was also difference between RV volume in 4-plane and that in 8-plane (P<0.05), but there was no significant difference between RV volume in 8-plane and that in 16-plane (P>0.05); (3) Inter-observers and intro-observers variability analysis showed that there were close agreements and relations for RV volumes (r=0.986,P<0.001;r=0.93,P<0.001); (4) There was a significantly positive correlation of TASE to RVSV and RVEF from RT3DE (r=0.83;r=0.90). So RV volume measures with RT3DE are rapid, accurate and reproducible. In view of RV's complex shape, apical 8-plane method is better in clinical use. It may allow early detection of RV systolic function.

Keywords

real-time three-dimensional echocardiography / right ventricular volume / apical 8-plane / right ventricular systolic function

Cite this article

Download citation ▾
Wang Jing, Wang Xinfang, Xie Mingxing, Yang ya, LV Qing, Yang Ying, Wang Liangyu. Evaluation of right ventricular volume and systolic function by realtime three-dimensional echocardiography. Current Medical Science, 2005, 25(28): 94-96 DOI:10.1007/BF02831398

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

SchinderaS T, MehwaldP S, SahnD L, et al. . Accuracy of real-time three-dimensional echocardiography for quantifying right ventricular volume: static and pulsatile flow studies in an anatomic in vitro model. J Ultrasound Med, 2002, 211069-1069

[2]

KissloJ, FirekB, OtaT, et al. . Real-time, volumetric echocardiography: the technology and the possibilities. Echocardiography, 2002, 17773-773

[3]

McCreeryC J, McCullochM, AhmadM, et al. . Real-time 3-dimensional echocardiography imaging for right ventricular endomyocardial biopsy: a comparison with fluoroscopy. J Am Soc Echocardiogr, 2001, 14927-927

[4]

MullerS, BartelT, PachingerO, et al. . 3-D echocardiography: new developments and future prospects. Herz, 2002, 27(3): 227-227

[5]

HubkaM, BolsonE L, McDonaldJ A, et al. . Three-dimensional echocardiographic measurement of left and right ventricular mass and volume: in vitro validation. Int J Cardiovasc Imaging, 2002, 8111-111

[6]

OtaT, KissiloJ, VonRammO T, et al. . Realtime, volumetric echocardiography: usefulness of volumetric scanning for the assessment of cardiac volume and function. J Cardial, 2001, 37(suppl 1): 93-93

[7]

WangX F. Real-time three-dimensional imaging-new breakthrough in the field of ultrasound technique. Chin J Ultrasonogr, 2003, 1271-71

[8]

WangX F. Real-time three-dimensional imaging-principle and clinical application future. BME & Clin Med, 2002, 18(1): 73-73

[9]

AhmadM. Real-time three-dimensional echocardiogra-phy in assessment of heart disease. Echocardiography, 2001, 1873-73

[10]

WangJ, WangX F, XieM X, et al. . Initial study of measurement methodology for right ventricular volume by real-time three-dimensional echocardiography. Chin J Ultrasonogr, 2003, 1290-90

[11]

FeiH W, WangX F, XieM X, et al. . Validation of real-time three-dimensional echocardiography for quantifying left ventricular volume: Experiment study. Chin J Ultrasonogr, 2003, 12426-426

[12]

KaulS, TeiC, HopkinsJ M, et al. . Assessment of right ventricular function using two-dimensional echocardiography. Am Heart J, 1984, 107526-526

AI Summary AI Mindmap
PDF

79

Accesses

0

Citation

Detail

Sections
Recommended

AI思维导图

/