Comparison of morphology and microstructural components of hepatic portal vein between human and pig

Zhang Yifei , Huang Tiezhu , Wang Peijun , Li Wenchun , Yu Minghua

Current Medical Science ›› 2005, Vol. 25 ›› Issue (14) : 419 -422.

PDF
Current Medical Science ›› 2005, Vol. 25 ›› Issue (14) : 419 -422. DOI: 10.1007/BF02828212
Article

Comparison of morphology and microstructural components of hepatic portal vein between human and pig

Author information +
History +
PDF

Abstract

In order to provide morphological data and theoretical basis for pig-to-human hepatic xenotransplantation, the difference in morphological parameters and vessel wall structural factors between human and porcine hepatic portal vein was studied. From human subjects and pigs of varying ages, hepatic portal veins were collected, paraffin-embedded and cut into sections. The histological structures were stained with HE, and elastin, collagen and smooth muscles were stained with Weigert, Aniline blue and orange G, respectively. Morphological parameters and relative contents of structural components were determined under microscopy and by computer image analysis system, respectively. The results showed that histological structures of human and porcine hepatic portal vein wall were similar. Caliber, wall thickness, lumen and wall area in pigs increased with age, all in linear correlation to months. Morphological parameters of 6-month-old pigs were similar to those of human. In pigs, collagen content increased gradually with months, elastin content remained relatively stable, smooth muscle content reached the peak at the 3rd month, and collagen/elastin (C/E) rose gradually. The contents of collagen and elastin in porcine hepatic portal vein wall were lower, while the content of smooth muscle was higher than in human, and C/E at the 5th and 6th month was similar to that in human. It is concluded that morphological parameters and contents of structural components of porcine hepatic portal vein vary with age. At the 6 month, its caliber, wall thickness, lumen and wall area are similar to those of human. There are differences in contents of structural components between human and pigs. However, in terms of C/E, mechanic properties of pigs at the 5th and 6th month mimic those of human, hence inosculation is viable in xenotrans-plantation between pigs and human.

Keywords

hepatic portal vein / microstructure / pig / xenotransplantation

Cite this article

Download citation ▾
Zhang Yifei, Huang Tiezhu, Wang Peijun, Li Wenchun, Yu Minghua. Comparison of morphology and microstructural components of hepatic portal vein between human and pig. Current Medical Science, 2005, 25(14): 419-422 DOI:10.1007/BF02828212

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

MakowaL, CramerD V, HoffmanA, et al.. The use of a pig liver xenograft for temporary support of a patient with fulminant hepatic failure. Transplantation, 1995, 59: 1654-1654

[2]

HayashiS, NamiiY, NagasakaT, et al.. Application of intraoperative intrahepatic portosystemic shunt in split-liver transplantation of the pig. Transplant Proc, 1998, 30: 3225-3225

[3]

TerajimaH, ShirakataY, YagiT, et al.. Successful long-term xenoperfusion of the pig liver: continuous administration of prostaglandin E1 and insulin. Transplantation, 1997, 63: 507-507

[4]

FungJ, RaoA, StarzlT. Clinical trials and projected future of liver xenotransplantation. World J Surg, 1997, 21: 956-956

[5]

YuY Y, JiJ, ZhouG W, et al.. Liver biopsy in evaluation of complications following liver transplantation. World J Gastroenterol, 2004, 10: 1678-1678

[6]

MiJ H, ChenE Y. Improvement on quantitative analysis method for blood vessel smooth muscle. Chim J Anat (Chinese), 1999, 22: 183-183

[7]

SonessonB, HansenF, StaleH, et al.. Compliance and diameter in the human abdominal aorta—the influence of age and sex. Eur J Vasc Surg, 1993, 7: 690-690

[8]

HuonkerM, HalleM, KeulJ. Structural and functional adaptations of the cardiovascular system by training. Int J Sports Med, 1996, 17(Suppl 3): 164-164

[9]

CampbellG R, CampbellJ H, MandersonJ A, et al.. Arterial smooth muscle. A multifunctional mesenchymal cell. Arch Pathol Lab Med, 1988, 112: 977-977

[10]

DobrinP B, RovickA A. Influence of vascular smooth muscle on contractile mechanics and elasticity of arteries. Am J Physiol, 1969, 217: 1644-1644

[11]

SunW Q, WangH Q, ZhangL P, et al.. Quantitative analysis of aging changes of tissue structure of human umbilical cord vein. Chin J Anat (Chinese), 2002, 25: 169-169

[12]

HosodaY, KawanoK, YamasawaF, et al.. Age-dependent changes of collagen and elastin content in human aorta and pulmonary artery. Angiology, 1984, 35: 615-615

[13]

SamilaZ J, CarterS A. The effect of age on the unfolding of elastin lamellae and collagen fibers with stretch in human carotid arteries. Can J Physiol Pharmacol, 1981, 59: 1050-1050

[14]

CoxR H. Passive mechanics and connective tissue composition of canine arteries. Am J Physiol, 1978, 234: H533-H533

[15]

HassonJ E, MegermanJ, AbbottW M. Postsurgical changes in arterial compliance. Arch Surg, 1984, 119: 788-788

AI Summary AI Mindmap
PDF

85

Accesses

0

Citation

Detail

Sections
Recommended

AI思维导图

/