Influence of contractility on myocardial ultrasonic integrated backscatter and cyclic variation in integrated backscatter

Bi Xiaojun , Deng Youbin , Pan Min , Yang Haoyi , Xiang Huijuan , Chang Qing , Li Chunlei

Current Medical Science ›› 2002, Vol. 22 ›› Issue (18) : 233 -234.

PDF
Current Medical Science ›› 2002, Vol. 22 ›› Issue (18) : 233 -234. DOI: 10.1007/BF02828189
Article

Influence of contractility on myocardial ultrasonic integrated backscatter and cyclic variation in integrated backscatter

Author information +
History +
PDF

Abstract

To evaluate the effects of left ventricular contractility on the changes of average image intensity (AII) of the myocardial integrated backscatter (IB) and cyclic variation in IB (CVIB), 7 adult mongrel dogs were studied. The magnitude of AII and CVIB were measured from myocardial IB carves before and after dobutamine or propranolol infusion. Dobutamine or propranolol did not affect the magnitude of AII (13.8±0.7 vs 14.7±0.5,P>0.05 or 14.3±0.5 vs 14.2±0.4,P>0.05). However, dobutamine produced a significant increase in the magnitude of CVIB (6.8±0.3 vs 9.5±0.6,P<0.001) and propranolol induced significant decrease in the magnitude of CVIB (7.1±0.2 vs 5.2±0.3,P<0.001). The changes of the magnitude of AII and CVIB in the myocardium have been demonstrated to reflect different myocardial physiological and pathological changes respectively. The alteration of contractility did not affect the magnitude of AII but induced significant change in CVIB. The increase of left ventricular contractility resulted in a significant rise of the magnitude of CVIB and the decrease of left ventricular contractility resulted in a significant fall of the magnitude of CVIB.

Keywords

myocardial contractility / average image intensity (AII) / cyclic variation in integrated backscatter (CVIB)

Cite this article

Download citation ▾
Bi Xiaojun, Deng Youbin, Pan Min, Yang Haoyi, Xiang Huijuan, Chang Qing, Li Chunlei. Influence of contractility on myocardial ultrasonic integrated backscatter and cyclic variation in integrated backscatter. Current Medical Science, 2002, 22(18): 233-234 DOI:10.1007/BF02828189

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

SchecterS O, TeichhlozL E, KligV, et al.. Ultrasonic tissue characterization. Echocardiography, 2002, 13: 415-415

[2]

MadarasE I, BarizaiB, PerezJ E, et al.. Changes in myocardial backscatter tissue characterization throughout the cardiac cycle. Ultrasound Imaging, 1983, 5: 29-29

[3]

HoytR H, SkortonD J, CottirsS M, et al.. Ultrasonic backscatter and collagen in normal ventricular myocardium. Circulation, 1984, 69: 775-775

[4]

O'BreinP D, O'BreinW D, RhyneT L, et al.. Relation of ultrasonic backscatter and acoustic propagation properties to myofibrillar length and myocardial thickness. Circulation, 1995, 91: 171-171

[5]

NaitoJ, MasuyamsT, ManoT, et al.. Influence of preload, afterload, and contractility on myocardial ultrasonic tissue characterization with integrated backscatter. Ultrasound in Med & Biol, 2002, 22(3): 305-305

[6]

SaeianK, RhyneT L, SagsarL B. Ultrasonic tissue characterization for diagnosis of acute myocardial infarction in the coronary care unit. Am J Cariol, 1994, 74: 1211-1211

AI Summary AI Mindmap
PDF

81

Accesses

0

Citation

Detail

Sections
Recommended

AI思维导图

/