Abstract

The central corneal thickness (CCT) in age 48 years or less of Chinese was characterized and its relationship with gender, age, refraction and intraocular pressure (IOP) was investigated. Right eyes of 1669 participants were included in this study (880 men, 52.7% and 789 women, 47.3%). Mean age of the samples was 23.8±5.9 years. After the examination of corneal topography and refraction. Goldman applanation tonometry was carried out by one physician. Tonometric values were the mean of three consecutive readings. Subsequently, another physician carried out ultrasonic pachymetry with the DGH 2000 AP ultrasonic pachymeter. Six measurements were made at the center of the cornea of each eye. The mean value was used for analysis. The results showed that mean CCT of male participants was 551.33±34.62 μm, 5.79 μm more than that of female participants. Linear regression analyses revealed that CCT was negatively related with age only in female and no association was found between refractive status and CCT. IOP was positively related to CCT, and there was a difference in IOP of 1.5 mmHg (1 mmHg=0.133 kPa) per 100 μm difference in CCT. Ocular hypertension group was prone to have thicker cornea than average. The results indicated that in adult Chinese CCT tended to decrease with aging in female only. IOP measured by Goldmann tonometry was positively related with CCT so that CCT should be measured along with IOP.

Keywords

central corneal thickness / intraocular pressure / gender / age / refraction

Cite this article

Download citation ▾
Li Pengcheng, Hu Yanhua, Xu Qian, Zhang Guangming, Mat Caikeng. Central corneal thickness in adult Chinese. Current Medical Science, 2006, 26(40): 141-144 DOI:10.1007/BF02828062

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

DoughtyM J, ZamanM L. Human corneal thickness and its impact on intraocular pressure measures: a review and meta-analysis approach. Surv Ophthalmol, 2000, 44: 367-408

[2]

AbbasogluO E, BowmanR W, CavanaghH D, et al.. Reliability of intraocular pressure measurements after myopic excimer photorefractive keratectomy. Ophthalmology, 1998, 105: 2193-2196

[3]

EmaraB, ProbstL E, TingeyD P, et al.. Correlation of intraocular pressure and central corneal thickness in normal myopic eyes and after laser in situ keratomileusis. J Cataract Refract Surg, 1998, 24: 1320-1320

[4]

CoptR P, ThomasR, MermoudA. Corneal thickness in ocular hypertension, primary-open-angle glaucoma, and normal tension glaucoma. Arch Ophthalmol, 1999, 117: 14-16

[5]

FeltgenN, LeifertD, FunkJ. Correlation between central corneal thickness, applanation tonometry, and direct intracameral IOP readings. Br J Ophthalmol, 2001, 85: 85-87

[6]

La RosaF A, GrossR L, Orengo-NaniaS. Central corneal thickness of Caucasians and African Americans in glaucomatous and nonglaucomatous populations. Arch Ophthalmol, 2001, 119: 23-27

[7]

HahnS, AzenS, Ying-LaiM, et al.. Central corneal thickness in Latinos. Invest Ophthalmol Vis Sci, 2003, 44: 1508-1512

[8]

FosterP J, BaasanhuJ, AlsbirkP H, et al.. Central corneal thickness and intraocular pressure in a Mongolian population. Ophthalmology, 1998, 105: 969-973

[9]

ChoP, LamC. Factors affecting the central corneal thickness of Hong Kong-Chinese. Curr Eye Res, 1999, 18: 368-374

[10]

HolladayJ T, AllisonM E, PragerT C. Goldmann applanation tonometry in patients with regular corneal astigmatism. Am J Ophthalmol, 1983, 96: 90-93

[11]

EhlerN, BramsenT, SperlingS. Applanation tonometry and central corneal thickness. Acta Ophthalmol (Copenth), 1975, 53: 34-43

[12]

LamA K, DouthwaiteW A. The effect of an artificially-elevated intraocular pressure on corneal thickness in Chinese eye. Ophthalmic Physiol Opt, 1997, 17: 414-414

[13]

WolfsR C, KlaverC C, VingerlingJ R, et al.. Distribution of central corneal thickness and its association with intraocular pressure: The Rotterdam Study. Am J Ophthalmol, 1997, 123: 767-772

[14]

NemesureB, WuS Y, HennisA, et al.. Corneal thickness and intraocular pressure in the Barbados eye studies. Arch Ophthalmol, 2003, 121: 240-244

[15]

IleoA, MarcosA, CalatayudM, et al.. The relationship between central corneal thickness and Goldmann applanation tonometry. Clin Exp Optom, 2003, 86: 104-108

[16]

FaragherR G, MulhollandB, TuftS J, et al.. Aging and the cornea. Br J Ophthalmol, 1997, 81: 814-817

[17]

TanakaH M, MoriE S, MainN, et al.. Corneal thickness in high myopes. Invest Ophthalmol Vis Sci, 1966, 37: 560-560

[18]

GoldmannH, SchmidtT. Uber Appalantationstonometrie. Ophthalmologica, 1957, 134: 221-242

[19]

BhanA, BrowningA C, ShahS, et al.. Effect of corneal thickness on intraocular pressure measurements with the pneumotonometer, Goldmann applanation tonometer, and Tono-Pen. Invest Ophthalmol Vis Sci, 2002, 43: 1389-1392

[20]

HerndonL W, WeizerJ S, StinnettS S. Central corneal thickness as a risk factor for advanced glaucoma damage. Arch Ophthalmol, 2004, 122: 17-21

[21]

MedeirosF A, SampleP A, ZangwillL M, et al.. Corneal thickness as a risk factor for visual field loss in patients with preperimetric glaucomatous optic neuropathy. Am J Ophthalmol, 2003, 136: 805-813