Industrial-scale investigations on effects of tertiary-air declination angle on combustion and steam temperature characteristics in a 350-MW supercritical down-fired boiler

Xiaoguang LI, Lingyan ZENG, Hongye LIU, Yao LI, Yifu LI, Yunlong ZHAO, Bo JIAO, Minhang SONG, Shaofeng ZHANG, Zhichao CHEN, Zhengqi LI

PDF(1433 KB)
PDF(1433 KB)
Front. Energy ›› 2021, Vol. 15 ›› Issue (1) : 132-142. DOI: 10.1007/s11708-020-0803-z
RESEARCH ARTICLE
RESEARCH ARTICLE

Industrial-scale investigations on effects of tertiary-air declination angle on combustion and steam temperature characteristics in a 350-MW supercritical down-fired boiler

Author information +
History +

Abstract

Industrial-scale experiments were conducted to study the effects of tertiary air declination angle (TDA) on the coal combustion and steam temperature characteristics in the first 350-MW supercritical down-fired boiler in China with the multiple-injection and multiple-staging combustion (MIMSC) technology at medium and high loads. The experimental results indicated that as the TDA increased from 0° to 15°, the overall gas temperature in the lower furnace rose and the symmetry of temperature field was enhanced. The ignition distance of the fuel-rich coal/air flow decreased. In near-burner region, the concentration of O2 decreased while the concentrations of CO and NO increased. The concentration of NO decreased in near-tertiary-air region. The carbon in fly ash decreased significantly from 8.40% to 6.45% at a load of 260 MW. At a TDA of 15°, the ignition distances were the shortest (2.07 m and 1.73 m) at a load of 210 MW and 260 MW, respectively. The main and reheat steam temperatures were the highest (557.2°C and 559.4°C at a load of 210 MW, 558.4°C and 560.3°C at a load of 260 MW). The carbon in fly ash was the lowest (4.83%) at a load of 210 MW. On changing the TDA from 15° to 25°, the flame kernel was found to move downward and the main and reheat steam temperatures dropped obviously. The change of TDA has little effect on NOx emissions(660–681 mg/m3 at 6% O2). In comprehensive consideration of the pulverized coal combustion characteristics and the unit economic performance, an optimal TDA of 15° is recommended.

Keywords

supercritical down-fired boiler / industrial-scale experiment / tertiary air declination angle / coal combustion / steam temperature

Cite this article

Download citation ▾
Xiaoguang LI, Lingyan ZENG, Hongye LIU, Yao LI, Yifu LI, Yunlong ZHAO, Bo JIAO, Minhang SONG, Shaofeng ZHANG, Zhichao CHEN, Zhengqi LI. Industrial-scale investigations on effects of tertiary-air declination angle on combustion and steam temperature characteristics in a 350-MW supercritical down-fired boiler. Front. Energy, 2021, 15(1): 132‒142 https://doi.org/10.1007/s11708-020-0803-z

References

[1]
Kuang M, Li Z Q. Review of gas/particle flow, coal combustion, and NOx emission characteristics within down-fired boilers. Energy, 2014, 69: 144–178
CrossRef Google scholar
[2]
Yang W, Wang B, Lei S Y, Wang K, Chen T, Song Z J, Ma C, Zhou Y D, Sun L S. Combustion optimization and NOx reduction of a 600 MWe down-fired boiler by rearrangement of swirl burner and introduction of separated over-fire air. Journal of Cleaner Production, 2019, 210: 1120–1130
CrossRef Google scholar
[3]
Burdett N A. The effects of air staging on NOx emissions from a 500 MWe down-fired boiler. Journal of the Institute of Energy, 1987, 60(444): 103–107
[4]
Luo Z X, Wang F, Zhou H C, Liu R T, Li W C, Chang G Z. Principles of optimization of combustion by radiant energy signal and its application in a 660 MWe down- and coal-fired boiler. Korean Journal of Chemical Engineering, 2011, 28(12): 2336–2343
CrossRef Google scholar
[5]
Cahill P, Beeley T J, O’Connor M, Spence J, Gibbins J R, Man C K. The assessment of low volatile fuels for downshot fired boilers. In: Proceedings of the 10th International Conference on Coal Science, Taiyuan, China, 1999
[6]
Achim D, Naser J, Morsi Y S, Pascoe S. Numerical investigation of full scale coal combustion model of tangentially fired boiler with the effect of mill ducting. Heat and Mass Transfer, 2009, 46(1): 1–13
CrossRef Google scholar
[7]
Wei Y H, Kuang M, Zhu Q Y, Ling Z Q, Ti S G, Li Z Q. Alleviating gas/particle flow deflection and asymmetric combustion in a 600 MWe supercritical down-fired boiler by expanding its furnace throat space. Applied Thermal Engineering, 2017, 123: 1201–1213
CrossRef Google scholar
[8]
Otero P, González J F, Rodríguez F, Caéadas L, Cortñs V. NOx reduction in arch-fired boilers by parametric tuning of operating conditions. In: Proceedings of the Electric Power Research Institute (EPRI) / Environmental Protection Agency (EPA) Mega symposium, Washington D.C., USA, 1997
[9]
Wang Q X, Chen Z C, Han H, Zeng L Y, Li Z Q. Experimental characterization of anthracite combustion and NOx emission for a 300-MWe down-fired boiler with a novel combustion system: influence of primary and vent air distributions. Applied Energy, 2019, 238: 1551–1562
CrossRef Google scholar
[10]
Song M H, Zeng L Y, Li X G, Liu Y B, Chen Z C, Li Z Q. Effects of tertiary air damper opening on flow, combustion and hopper near-wall temperature of a 600 MWe down-fired boiler with improved multiple-injection multiple-staging technology. Journal of the Energy Institute, 2018, 91(4): 573–583
CrossRef Google scholar
[11]
Ministry of Environmental Protection of the People’s Republic of China. Emission Standard of Air Pollutants for Boiler (GB13271–2014). Beijing: China Environmental Science Press, 2014 (in Chinese)
[12]
Liu G K, Li Z Q, Chen Z C,Zhu X Y, Zhu Q Y. Effect of the anthracite ratio of blended coals on the combustion and NOx emission characteristics of a retrofitted down-fired 660-MWe utility boiler. Applied Energy, 2012, 95: 196–201
CrossRef Google scholar
[13]
Song M H, Zeng L Y, Yang X C, Chen Z C, Li Z Q. Influence of the mass ratio of pulverized-coal in fuel-rich flow to that in fuel-lean flow on the gas/particle flow and particle distribution characteristics in a 600 MWe down-fired boiler. Experimental Thermal and Fluid Science, 2018, 91: 363–373
CrossRef Google scholar
[14]
Plumed A, Cañadas L, Otero P, Espada M I, Castro M, Gonzálcz J F, Rodríguez F. Primary measures for reduction of NOx in low volatile coals combustion. Coal Science and Technology, 1995, 24: 1783–1786
CrossRef Google scholar
[15]
Li Z Q, Kuang M, Zhu Q Y, Lai J P, Zhang Y. Aerodynamic characteristics within a cold small-scale model for a downfired 350 MWe utility boiler applying a multiple-injection and multiple-staging technology: effect of the staged-air declination angle. Experimental Thermal and Fluid Science, 2012, 38: 184–194
CrossRef Google scholar
[16]
Song M H, Zeng L Y, Chen Z C, Li Z Q, Zhu Q Y, Kuang M. Industrial application of an improved multiple injection and multiple staging combustion technology in a 600 MWe supercritical down-fired boiler. Environmental Science & Technology, 2016, 50(3): 1604–1610
CrossRef Google scholar
[17]
Zhao Y L, Wang C Y, Liu M, Chong D T, Yan J J. Improving operational flexibility by regulating extraction steam of high-pressure heaters on a 660 MW supercritical coal-fired power plant: a dynamic simulation. Applied Energy, 2018, 212: 1295–1309
CrossRef Google scholar
[18]
Dong J C, Fan H J, Wu X J, Zhou T, Zhang J, Zhang Z X. Study on the effect of flame offset on water wall tube temperature in 600°C and 700°C ultra-supercritical boiler. Combustion Science and Technology, 2019, 191(3): 472–490
CrossRef Google scholar
[19]
Zima W. Simulation of rapid increase in the steam mass flow rate at a supercritical power boiler outlet. Energy, 2019, 173: 995–1005
CrossRef Google scholar
[20]
Kuang M, Li Z Q, Ling Z Q, Chen Z F, Yuan D Y. Characterization of coal combustion and steam temperature with respect to staged-air angle in a 600 MWe down-fired boiler. Energy & Fuels, 2014, 28(6): 4199–4205
CrossRef Google scholar
[21]
Li Z Q, Ren F, Liu G K, Shen S P, Chen Z C. Influence of angled secondary air on combustion characteristics of a 660-MWe down-fired utility boiler. Combustion Science and Technology, 2010, 183(3): 238–251
CrossRef Google scholar
[22]
Fang Q Y, Wang H J, Zhou H C, Lei L, Duan X L. Improving the performance of a 300 MW down-fired pulverized-coal utility boiler by inclining downward the F-layer secondary air. Energy & Fuels, 2010, 24(9): 4857–4865
CrossRef Google scholar
[23]
Liang L, Hui S E, Zhao S, Zhou Q L, Xu T M, Zhao Q X. Cold modeling investigation of aerodynamic characteristics of an arch-fired boiler on particle image velocimetry (PIV): influence of momentum flux ratio of arch air to secondary air and secondary air angle. Experimental Thermal and Fluid Science, 2012, 42: 240–247
CrossRef Google scholar
[24]
Fan Q G. Subcritical and Supercritical Boiler. Beijing: China Electric Power Press, 2000 (in Chinese)
[25]
Wang X H. Discussion on water wall cracking of supercritical down-fired boiler. Hunan Electric Power, 2012, 32(1): 48–52 (in Chinese)

Acknowledgments

This work was supported by the National Natural Science Foundation of China (51706054) and the China Postdoctoral Science Foundation (Grant No. 2019M660633).

RIGHTS & PERMISSIONS

2020 Higher Education Press
AI Summary AI Mindmap
PDF(1433 KB)

Accesses

Citations

Detail

Sections
Recommended

/