About the journal
Browse
Authors & reviewers
Coordinated Semi-active Pitch Control of a Floating Photovoltaic Platform with Multiple Wave Energy Converters Through Power Take-off Damping Regulation
Hengxu Liu , Yihao Zhang , Yupeng Duan , Yuanchao Chai , Xiongbo Zheng , Hailong Chen , Keyue Zhang , Yahui Zhou
Journal of Marine Science and Application ›› : 1 -18.
This study addresses the relatively large pitch response of semi-submersible floating platforms under wave action and the difficulty of balancing platform stability with wave-energy absorption when fixed-damping power take-off (PTO) floats are used. A stability-oriented coordinated semi-active variable-damping method is proposed for a coupled floating photovoltaic (FPV) platform and wave energy converter (WEC) system consisting of a four-column semi-submersible photovoltaic platform and four annular wave-energy floats nested around the columns. The method combines position-weighted multi-PTO moment allocation, conversion of the requested control action into a bounded non-negative dissipative damping law, and soft-stop stroke protection. Frequency-domain hydrodynamic coefficients are obtained using ANSYS AQWA and transferred to WEC-Sim; the two models give consistent peak locations and overall trends for the pitch response amplitude operator (RAO). A separate RM3 benchmark using AQWA-derived hydrodynamic data reproduces the published relative-heave RAO trend and agrees with wave-tank measurements over the main-response range. Under the representative sea state, the semi-active control reduces the standard deviation and maximum absolute value of pitch by 26.57% and 10.51%, respectively, relative to the fixed high-damping case of 150 kN · s/m, without increasing the peak conventional PTO damping force. Across multiple sea states and random phase seeds, the V150 case achieves average reductions of 24.05% in pitch standard deviation and 17.69% in maximum absolute pitch relative to the fixed-damping baseline. Across five sea states and three random phase seeds, the soft-stop reduces the maximum relative displacement by 5.55%–36.60%, the maximum stroke exceedance by 40.12%–60.48%, and the exceedance duration by 17.93%–26.48%. The maximum total connection force reaches 202.34 kN. The results demonstrate both the stability benefit of coordinated control and the structural-load demand associated with soft-stop protection.
Floating photovoltaic / Wave energy converter / Power take-off damping / Semi-active control / Pitch mitigation / Soft-stop
| [1] |
|
| [2] |
American Petroleum Institute. American Petroleum Institute (API) Recommended Practice 2SK Design and analysis of stationkeeping systems for floating structures, 20053rd EditionWashington, D.C.API |
| [3] |
|
| [4] |
|
| [5] |
|
| [6] |
|
| [7] |
DNV GL. DNVGL-OS-E301 Position mooring, 2015, Oslo: DNV GL |
| [8] |
|
| [9] |
|
| [10] |
|
| [11] |
|
| [12] |
|
| [13] |
|
| [14] |
|
| [15] |
|
| [16] |
|
| [17] |
|
| [18] |
|
| [19] |
|
| [20] |
|
| [21] |
|
| [22] |
|
| [23] |
|
| [24] |
|
| [25] |
|
| [26] |
|
| [27] |
|
| [28] |
|
| [29] |
|
| [30] |
|
| [31] |
|
| [32] |
|
| [33] |
|
| [34] |
|
Harbin Engineering University and Springer-Verlag GmbH Germany, part of Springer Nature
/
| 〈 |
|
〉 |